ABB 1SFL477001R6911 Block Contactor - CE & UL/CSA
Part Number: 1SFL477001R6911
Quick Summary
Block Contactor ABB 1SFL477001R6911 provides reliable motor starting for industrial drives. Engineers often face coil voltage mismatches and downtime caused by undersized or incompatible controllers. This model carries CE, UL/CSA, and cULus listings to support global compliance and safer operation. With a wide control voltage range of 48–130 V and 3-pole main circuits up to 690 V, it offers installation flexibility across a variety of equipment. Designed for robust performance in demanding environments, it helps reduce maintenance costs and improve line uptime, delivering consistent switching performance in conveyors, pumps, and tooling applications.
Product Information
Extended Description
1SFL477001R6911 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL447002R1211
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540923-7
Product Net Width
111.5 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
3.4 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 180 A | (1000 V) 55 °C 180 A | (1000 V) 70 °C 180 A | (690 V) 40 °C 250 A | (690 V) 55 °C 230 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 145 A | (440 V) 55 °C 145 A | (500 V) 55 °C 145 A | (690 V) 55 °C 120 A | (1000 V) 55 °C 80 A | (380 / 400 V) 55 °C 145 A | (220 / 230 / 240 V) 55 °C 145
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 75 kW | (500 V) 90 kW | (690 V) 110 kW | (1000 V) 110 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Power Loss
at Rated Operating Conditions per Pole 5 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm² | Rigid Al-Cable 1 x 25 ... 150 mm² | Rigid Cu-Cable 1 x 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 24 mm² | Rigid Al-Cable 1 x 25 ... 150 mm² | Rigid Cu-Cable 1 x 6 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 230 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 40 hp | (208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69478
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CQC Certificate, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
cUL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CCC Declaration of Conformity, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20261-04HH
LOVAG Certificate
SE-0105160
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
178 mm
Package Level 1 Depth / Length
232 mm
Package Level 1 Height
167 mm
Package Level 1 Gross Weight
3.6 kg
Package Level 1 EAN
7320500220184
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Norway)
4115266
E-Number (Sweden)
3228284
Feature: Wide coil voltage range 48–130 V AC/DC enables flexible control from existing plant supplies. Business Impact: Reduces wiring complexity and inventory needs, shortening commissioning time. Application: Retrofit projects or new installations where control voltage varies across equipment. Feature: 3-pole main circuit up to 690 V with 3 NO main contacts and 1 NO/1 NC auxiliary contact. Business Impact: Supports reliable three-phase motor start and provides signaling capability for control circuits. Application: Motor starting, isolation, bypass, and distribution in heavy-duty drives. Feature: Rated operational current AC-3 up to 120 A at 690 V and AC-1 up to 250 A at 690 V. Business Impact: Handles high-power loads with defined duty ratings, improving reliability and uptime. Application: Pumps, conveyors, and presses in demanding environments. Feature: Mechanical durability rated at 5 million operations and robust connection options. Business Impact: Lower maintenance costs and longer service life with fewer field failures. Application: Continuous-duty industrial lines requiring durable switching. Feature: Flexible mounting and connection options with Bar terminals and rigid Al/Cu cables; tightening torque 18 N·m. Business Impact: Simplifies installation, reduces assembly time, and improves electrical integrity. Application: Safe, code-compliant wiring in panel assemblies and switchgear cabinets.
Get a Quick Quote for a ABB 1SFL477001R6911
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL477001R6911?
Enquire Now
FAQs
The coil operates from 48–130 V AC/DC, while the main circuit is rated up to 690 V with three poles. This supports compatible control circuits and three-phase mains in most industrial installations.
AC-3 rated current at 690 V is 120 A, while AC-1 rated current at 690 V is 250 A. These figures reflect the device’s capability for motor starting (AC-1) and short-circuit switching (AC-3) in demanding applications.
Yes, it includes 1 NO and 1 NC auxiliary contact in addition to 3 main NO contacts, enabling signaling and control interlocks for safer and smarter control schemes.
Main circuit connections use bars or rigid Al-Cu cables (6–150 mm²), with a tightening torque of 18 N·m. Auxiliary circuits support flexible or solid conductors (2×0.75–4 mm²).
The product carries CE, UL/CSA, and cULus certifications, along with various other global declarations, facilitating compliance in multiple regions and simplifying procurement for multinational projects.