ABB AF190-30-22-32 Contactor - 1000V UL/CSA 250A

Part Number: 1SFL487002R3222
Manufacturer
ABB
Part number
1SFL487002R3222

Quick Summary

AF190-30-22-32 Contactor is a three-pole, 1000 V AC power switch designed for motor control in industrial applications. In real-world panels, voltage variations can drive nuisance tripping and energy waste; this device mitigates that with a broad coil-voltage range and a compact, robust design. It carries CE, UKCA, and UL/CSA certifications, supporting RoHS and REACH compliance for global deployment. The AF technology delivers reliable operation across supply fluctuations, while the integrated surge protection reduces collateral damage in demanding environments. With easy expansion through auxiliary contact blocks and a modular footprint, this contactor aligns with modern, energy-efficient automation strategies and cost-conscious panel building.

Product Information

Extended Description

1SFL487002R3222 ABB: The AF190-30-22-32 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 90 kW / 400 V AC (AC-3) or 125 hp / 480 V UL and switching power circuits up to 275 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
125 mm
Product Net Depth / Length
165.5 mm
Product Net Height
196 mm
Product Net Weight
2.4 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 275 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 190 A | (440 V) 60 °C 190 A | (500 V) 60 °C 156 A | (690 V) 60 °C 135 A | (1000 V) 60 °C 85 A | (380 / 400 V) 60 °C 190 A | (220 / 230 / 240 V) 60 °C 190 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 190 A | (440 V) 60 °C 190 A | (500 V) 60 °C 135 A | (690 V) 60 °C 135 A | (1000 V) 60 °C 85 A | (380 / 400 V) 60 °C 190 A | (220 / 230 / 240 V) 60 °C 190 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Operational Power AC-3e (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 2 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 2 W | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 15 W | at Rated Operating Conditions AC-3 per Pole 7 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 50 ... 95 mm² | Rigid Al-Cable 1 x 95 ... 185 mm² | Rigid Cu-Cable 1 x 6 ... 150 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M8 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 18 N·m | Control Circuit 1 N·m | Main Circuit 14 ... 31 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 250 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 301 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 150 A | (220 ... 240 V AC) Three Phase 154 A | (440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF190-30, AF205-30, AFS190-30, AFS205-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
160 mm
Package Level 1 Depth / Length
258 mm
Package Level 1 Height
235 mm
Package Level 1 Gross Weight
3 kg
Package Level 1 EAN
7320500561706
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: Wide coil voltage range of 48–130 V across 50/60 Hz and DC operation provides stable operation in networks with voltage drift, reducing pilot coil waste and panel heat; Application: automotive, packaging lines, and metal fabrication where supply quality varies. Feature → Business Impact → Application: Built-in surge protection guards the main and auxiliary circuits, lowering fault-induced downtime and protecting downstream drives; Application: conveyors, pumps, and fans in continuous operation. Feature → Business Impact → Application: Three-pole main circuit with 1000 V rating and 3P configuration supports motors up to 90 kW (AC-3) and 125 hp UL, enabling scalable drive interlocks in new builds; Application: shredders, presses, and extrusion lines. Feature → Business Impact → Application: 2 NO and 2 NC auxiliary contacts simplify interlocking and feedback, reducing wiring complexity and startup risk; Application: machine safety circuits and control logic. Feature → Business Impact → Application: AF block design allows add-on auxiliary blocks and accessories for tailored control schemes, accelerating panel assembly and future upgrades; Application: custom control panels and serviceable industrial plants. Feature → Business Impact → Application: Rated mechanical durability of 5 million cycles and high breaking capacity ensure long service life and predictable maintenance windows; Application: oil/gas processing, mining equipment, and heavy motor drives.

Get a Quick Quote for a ABB 1SFL487002R3222

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL487002R3222? Enquire Now

FAQs

Installation involves mounting the 3P block on a panel, wiring the main circuit with the bars, and connecting the auxiliary circuit per the datasheet. Use the recommended main circuit torque of 14–31 N·m and main circuit terminals with suitable lug sizes. Plan for 6–185 mm² conductors for rigid or flexible cables and ensure compliant IP ratings for coil and main terminals.
The coil supports 48–130 V for 50 Hz, 48–130 V for 60 Hz, and DC operation within the same range. This broad tolerance helps maintain operation during voltage swings and reduces the need for multiple coil variants in mixed supply environments.
Yes. It is rated for AC-3 operation across a range of voltages including 380–1000 V, delivering up to 190 A at 690–1000 V and 132 kW at higher line voltages in the AC-3 regime. It also provides 8 x Ie breaking capacity and robust make/break performance for demanding drives.
The AF190-30-22-32 is CE and UKCA certified, with UL/CSA listings for general use. It also complies with RoHS and REACH directives, and supports WEEE B2B disposal. These certifications facilitate global procurement and regulatory compliance across diverse markets.
The device’s high mechanical durability (up to 5 million cycles) and integrated surge protection reduce maintenance frequency and downtime. Its modular, block-style design accelerates wiring, expansion, and servicing, delivering lower lifecycle costs and faster return on investment in medium to high-duty motor installations.