ABB AF190B-30-22RT-12 Contactor - 1000 V UL/CSA Certified

Part Number: 1SFL487062R1222
Manufacturer
ABB
Part number
1SFL487062R1222

Quick Summary

ABB AF190B-30-22RT-12 Contactor is a 3-pole motor starter for IEC/UL motors up to 90 kW. In demanding automation environments, it delivers reliable switching and durable performance across fluctuating networks. The AF technology supports a wide control-voltage range of 48–130 V, allowing stable operation and reduced panel energy consumption even in unstable networks. Built-in surge protection and a compact block design minimize external components and simplify installation in tight control panels. With pre-mounted auxiliary contacts and easy expansion via add-on blocks, this device scales to complex motor-control circuits while maintaining simplicity. Certifications include CE, UL/CSA, and UKCA, reinforcing compliance across global standards and supporting predictable maintenance and total cost of ownership.

Product Information

Extended Description

1SFL487062R1222 ABB: The AF190B-30-22RT-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 90 kW / 400 V AC (AC-3) or 125 hp / 480 V UL and switching power circuits up to 275 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
105 mm
Product Net Depth / Length
153 mm
Product Net Height
196 mm
Product Net Weight
2.4 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 55 °C 225 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 190 A | (440 V) 55 °C 190 A | (500 V) 55 °C 135 A | (690 V) 55 °C 135 A | (1000 V) 55 °C 85 A | (380 / 400 V) 55 °C 190 A | (220 / 230 / 240 V) 55 °C 190 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 190 A | (440 V) 60 °C 190 A | (500 V) 60 °C 135 A | (690 V) 60 °C 135 A | (1000 V) 60 °C 85 A | (380 / 400 V) 60 °C 190 A | (220 / 230 / 240 V) 60 °C 190 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 250 A | (100 V) 1 Pole, 60 °C 250 A | (100 V) 1 Pole, 70 °C 200 A | (110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (175 V) 2 Poles in Series, 40 °C 250 A | (175 V) 2 Poles in Series, 60 °C 250 A | (175 V) 2 Poles in Series, 70 °C 200 A | (200 V) 2 Poles in Series, 40 °C 250 A | (200 V) 2 Poles in Series, 60 °C 250 A | (200 V) 2 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (260 V) 3 Poles in Series, 40 °C 250 A | (260 V) 3 Poles in Series, 60 °C 250 A | (260 V) 3 Poles in Series, 70 °C 200 A | (300 V) 3 Poles in Series, 40 °C 250 A | (300 V) 3 Poles in Series, 60 °C 250 A | (300 V) 3 Poles in Series, 70 °C 200 A | (72 V) 1-Pole, 40 °C 250 A | (72 V) 1-Pole, 60 °C 250 A | (72 V) 1-Pole, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A | (90 V) 1 Pole, 40 °C 250 A | (90 V) 1 Pole, 60 °C 250 A | (90 V) 1 Pole, 70 °C 200 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Operational Power AC-3e (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
7 W | at Rated Operating Conditions per Pole 7 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 250 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 150 A | (220 ... 240 V AC) Three Phase 154 A | (440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SE-82315
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF190B..RT - AF205B-30...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
160 mm
Package Level 1 Depth / Length
258 mm
Package Level 1 Height
235 mm
Package Level 1 Gross Weight
3 kg
Package Level 1 EAN
7320500510162
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Motor control capability with 3P 1000 V main circuit delivers up to 90 kW in AC-3 service, enabling compact motor-start solutions for pumps, fans, and conveyors. Business impact: higher motor efficiency, reduced panel space, and improved uptime. Application: general purpose motor control in OEM and end-user facilities. The AF technology offers a wide control voltage range 48–130 V (AC/DC), decreasing wiring complexity and reducing energy waste when supply voltages vary. This translates to lower operating temperatures and longer coil life in fluctuating networks. Built-in surge protection minimizes nuisance trips and external components, lowering total cost of ownership. The block design is easy to extend with add-on auxiliary contact blocks, supporting scalable control schemes for interlocking and remote signaling. Compatibility with IEC/EN 60947-1, 60947-4-1 and UL/CSA standards simplifies procurement and site validation. Pre-mounted auxiliaries (2 NO, 2 NC) reduce installation time and wiring errors in panel assemblies.

Get a Quick Quote for a ABB 1SFL487062R1222

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL487062R1222? Enquire Now

FAQs

The contactor supports 3P configurations with a main circuit rated at 1000 V and AC-3 ratings up to 190 A at 400 V (55 °C). It is suitable for motor control duties up to 90 kW, making it a robust fit for 380–400 V drives and similar systems.
The coil operation range is 48–130 V, applicable to both AC and DC control voltages, allowing stable operation despite control-supply variations.
Yes, the unit features built-in surge protection, reducing nuisance trips and enabling more reliable operation in networks with voltage transients.
Certifications include CE, UKCA, UL/CSA, cURus, CCC, CB, and EAC, along with RoHS compliance and a DoC for conformance, aligning with global regulatory requirements.
Yes. The AF190 family uses a block design that easily accommodates add-on auxiliary contact blocks, enabling scalable control wiring for complex interlocking or signaling needs.