ABB 1SFL487102R1400 Contactor - 1000 V IEC UL/CSA
Part Number: 1SFL487102R1400
Quick Summary
ABB 1SFL487102R1400 Contactor controls motors up to 90 kW in industrial panels. It handles voltage fluctuations with AF technology and a wide control voltage range. This device carries CE, UKCA, and UL/CSA approvals, ensuring global compliance for multi-region deployments. Its four-pole block design uses main circuit bars for robust, compact wiring, while offering easy expansion with add-on auxiliary contact blocks. Built-in surge protection and 1000 V insulation support reliable operation in demanding environments, reducing downtime and energy waste. By combining high performance with scalable accessories, it delivers meaningful total cost of ownership improvements and smoother integration into existing control architectures.
Product Information
Extended Description
1SFL487102R1400 ABB: The AF190-40-00-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 90 kW / 400 V AC (AC-3) / and switching power circuits up to 275 A (AC-1) or 230 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF190,AF205
Product Net Width
140 mm
Product Net Depth / Length
153 mm
Product Net Height
196 mm
Product Net Weight
3.3 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 55 °C 225 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 190 A | (440 V) 55 °C 190 A | (380 / 400 V) 55 °C 190 A | (220 / 230 / 240 V) 55 °C 190 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 355 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage DC 3.9 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
15 W | at Rated Operating Conditions per Pole 15 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Main Circuit
Flexible 2 x 50 ... 95 mm² | Rigid Al-Cable 1 x 95 ... 185 mm² | Rigid Cu-Cable 2 x 50 ... 120 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 18 N·m | Main Circuit 14 ... 31 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 250 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp | (200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 25 Hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 60 Hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 75 Hp | (550 ... 600 V AC) Three Phase 150 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-77322
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF190-40, AF205-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
166 mm
Package Level 1 Depth / Length
238 mm
Package Level 1 Height
180 mm
Package Level 1 Gross Weight
3.9 kg
Package Level 1 EAN
7320500504291
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707188
The four-pole construction with Main Circuit Bars provides a robust current path and a compact footprint, enabling reliable motor control while simplifying panel layout. This translates to reduced cabinet space and faster commissioning in manufacturing lines where downtime is costly. The AF technology delivers a wide control voltage range of 250 to 500 V (AC and DC), allowing stable operation amid voltage swings and helping you minimize energy waste across fluctuating networks. Built-in surge protection protects both the contactor and downstream drives, improving reliability in environments with electrical transients and extending equipment life. The AF190 family’s block-type design supports straightforward expansion with add-on auxiliary contact blocks, enabling scalable control circuits without rework. Connecting capacity supports both flexible and rigid cabling (2 x 50–95 mm² flexible; 1 x 95–185 mm² rigid Al; 2 x 50–120 mm² rigid Cu), simplifying field wiring and ensuring solid, vibration-resistant connections. Compatibility with CAD data, dimension diagrams, and a broad accessory ecosystem helps you optimize installation time and maintain accurate documentation. With a rated insulation voltage of 1000 V and IP20 coil terminals, this device is built for safe operation in demanding industrial settings, while offering up to 5 million mechanical cycles and 300 cycles per hour switching. In short, you gain a scalable, efficient motor protection and control solution that fits standard panels and reduces lifecycle costs across diverse applications.
Get a Quick Quote for a ABB 1SFL487102R1400
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL487102R1400?
Enquire Now
FAQs
The contactor supports flexible cables 2 x 50 to 95 mm² or rigid cables: Al-Cu 1 x 95 to 185 mm² for main circuits, with corresponding ranges for copper. This enables reliable, high-current wiring while keeping termination secure and vibration-resistant. For best results, use copper conductors within the stated ranges and follow tightening torque specifications to ensure low contact resistance and long-term performance.
The device provides an AC-3 rating of 190 A at 415 V (55 °C) and 190 A at 440 V (55 °C). The rated operating power in AC-3 is 90 kW at 415 V, with corresponding current ratings at other voltages. This makes it suitable for switching and starting medium to high-power motors in standard industrial applications while keeping within thermal limits.
Yes, the AF190 family includes built-in surge protection as part of its compact, energy-efficient design. This protection helps shield downstream equipment from voltage spikes during switching events, reducing nuisance tripping, wear on contacts, and extending the life of motors and drives connected to the contactor.
The model carries CE and UKCA declarations, and UL/cULus certification for the main contacts and overall assembly. Additional approvals include BV, RINA, and other certifications listed in the product data, ensuring compliance with regional electrical codes and enabling cross-border deployment in industrial facilities while meeting safety and performance requirements.
Consider using the main circuit bars for secure, low-resistance connections and follow the specified tightening torques for Main Circuit and Cable Lugs. The IP20 coil terminals and IP00 main terminals simplify protection design, while the modular block design allows adding auxiliary contacts as your control logic expands. Regular inspection of connections and keeping the panel environment within the listed ambient and altitude ranges will maintain performance and durability.