ABB AF190B-40-22RT-12 Contactor - CE UL/CSA 1000V
Part Number: 1SFL487262R1222
Quick Summary
ABB AF190B Contactor powers four-pole motor drives up to 90 kW at 400 V AC. In busy control panels, voltage swings and supply fluctuations can trigger unwanted trips, wasting time and energy. It carries CE, UKCA, and UL/CSA certifications, with RoHS and REACH declarations to help meet global compliance. The AF technology delivers a wide control voltage range and built-in surge protection, delivering reliability in unstable networks. Modular accessories and a compact block design enable scalable, streamlined motor protection and control for modern manufacturing environments.
Product Information
Extended Description
1SFL487262R1222 ABB: The AF190B-40-22RT-12 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 90 kW / 400 V AC (AC-3) / and switching power circuits up to 275 A (AC-1) or 230 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
153 mm
Product Net Height
196 mm
Product Net Weight
3.3 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 55 °C 225 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 190 A | (440 V) 55 °C 190 A | (380 / 400 V) 55 °C 190 A | (220 / 230 / 240 V) 55 °C 190 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 250 A | (100 V) 1 Pole, 60 °C 250 A | (100 V) 1 Pole, 70 °C 200 A | (110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (175 V) 2 Poles in Series, 40 °C 250 A | (175 V) 2 Poles in Series, 60 °C 250 A | (175 V) 2 Poles in Series, 70 °C 200 A | (200 V) 2 Poles in Series, 40 °C 250 A | (200 V) 2 Poles in Series, 60 °C 250 A | (200 V) 2 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (260 V) 3 Poles in Series, 40 °C 250 A | (260 V) 3 Poles in Series, 60 °C 250 A | (260 V) 3 Poles in Series, 70 °C 200 A | (300 V) 3 Poles in Series, 40 °C 250 A | (300 V) 3 Poles in Series, 60 °C 250 A | (300 V) 3 Poles in Series, 70 °C 200 A | (350 V) 4 Poles in Series, 40 °C 250 A | (350 V) 4 Poles in Series, 60 °C 250 A | (350 V) 4 Poles in Series, 70 °C 200 A | (400 V) 4 Poles in Series, 40 °C 250 A | (400 V) 4 Poles in Series, 60 °C 250 A | (400 V) 4 Poles in Series, 70 °C 200 A | (72 V) 1-Pole, 40 °C 250 A | (72 V) 1-Pole, 60 °C 250 A | (72 V) 1-Pole, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A | (90 V) 1 Pole, 40 °C 250 A | (90 V) 1 Pole, 60 °C 250 A | (90 V) 1 Pole, 70 °C 200 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Operational Power AC-3e (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
15 W | at Rated Operating Conditions per Pole 15 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 250 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp | (200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 25 Hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 60 Hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 75 Hp | (550 ... 600 V AC) Three Phase 150 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
CB Certificate
SEMKO_SE-77322
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF190B..RT-AF205B-40...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF190B..RT-AF205B-40...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
166 mm
Package Level 1 Depth / Length
238 mm
Package Level 1 Height
180 mm
Package Level 1 Gross Weight
3.9 kg
Package Level 1 EAN
7320500510209
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature AF technology provides a wide control voltage range from 48 to 130 V AC or DC, which reduces panel energy consumption and ensures distinct operation under supply variations. Business Impact This translates to fewer nuisance trips and more consistent motor operation in facilities with variable power quality. Application Used in motor protection and control for conveyors, pumps, and fans where voltage stability cannot be guaranteed without robust control electronics. Feature Pre-mounted auxiliary contacts (2 NO, 2 NC) and ring tongue ferrules simplify wiring and reduce panel assembly time, while maintaining reliable interconnections. Business Impact Faster start-up, lower wiring errors, and easier maintenance lead to lower total cost of ownership. Application Suitable for control circuits and interlocking schemes in automated lines and safety-rated applications. Feature Built-in surge protection and a compact block design enable easy expansion with add-on auxiliary blocks. Business Impact Enhances system reliability and reduces panel footprint, supporting scalable control architectures. Application Ideal for retrofits and new builds where space is at a premium and future upgrades are expected. Feature Rated AC-3 power up to 132 kW at 690 V and 110 kW at 1000 V, with AC-1 up to 250 A at 1000 V and 225 A at elevated temperatures. Business Impact Supports high-demand motor loads without compromising protection or lifetime. Application Suitable for heavy-duty processes and continuous-duty drives in manufacturing plants. Feature Coil consumption and power loss details: pull-in at rated voltage 180 VA, holding at rated voltage 4 VA, plus 15 W per pole power loss. Business Impact Predictable control energy use, easier cooling budgeting, and consistent coil performance across temperatures. Application Critical in panel optimization and energy-management initiatives. Feature Mechanical durability rated at 5 million cycles with a maximum switching frequency of 300 cycles per hour. Business Impact Long service life reduces maintenance intervals and downtime. Application Harsh environments with frequent switching, such as mining conveyors or process lines.
Get a Quick Quote for a ABB 1SFL487262R1222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL487262R1222?
Enquire Now
FAQs
The AF190B-40-22RT-12 supports a compact block design with main circuit bars and pre-mounted auxiliary contacts (2 NO, 2 NC). It is compatible with add-on auxiliary contact blocks and a wide range of accessories, enabling plug-and-play expansion. This simplifies wiring, reduces installation time, and supports scalable control architectures for future expansions in panel assemblies.
For AC-1 service at 1000 V, it achieves up to 250 A (at 40 °C), with values tapering at higher temperatures. For AC-3 operation (typical motor starting), ratings are up to 190 A at 415–690 V, with 275 A general use at 690 V under UL/CSA guidelines. DC ratings also apply in configured pole arrangements, making it versatile for mixed-voltage systems.
Yes. It carries CE and UKCA declarations for conformity, UL/CSA general use ratings, and RoHS/REACH declarations. Additional certifications include CCC and cURus where applicable, along with environmental data such as EPD and WEEE classifications, supporting compliant installation in global plants and sustainable procurement programs.
AF technology delivers a wide control voltage range (48–130 V AC/DC) and built-in surge protection, reducing energy waste and nuisance trips in networks with voltage fluctuations. It also lowers overall energy consumption through optimized coil usage and a compact, efficient design, improving system reliability in demanding industrial environments.
Ideal for automated manufacturing lines, conveyors, pumps, and HVAC or process control where robust motor protection and reliable switching are essential. Its high AC-3 power rating and modular accessory options make it suitable for automotive, food & beverage, water treatment, and general industrial applications requiring durable, scalable motor control solutions.