ABB 1SFL487262R1422 Contactor - 1000 V AF Technology

Part Number: 1SFL487262R1422
Manufacturer
ABB
Part number
1SFL487262R1422

Quick Summary

ABB AF Contactor AF190B-40-22RT-14 is a 4-pole motor starter designed to control motors up to 90 kW in industrial applications. In unstable networks, it helps manage large voltage variations and reduces panel energy consumption through a wide control voltage range and built‑in surge protection. It carries CE, UL/CSA General Use ratings, and UKCA compliance, supporting global deployment and consistent performance. This solution also integrates easily with modular auxiliary blocks, delivering reliable motor protection and control for modern automation projects while aligning with cost‑efficient panel design and maintenance strategies.

Product Information

Extended Description

1SFL487262R1422 ABB: The AF190B-40-22RT-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 90 kW / 400 V AC (AC-3) / and switching power circuits up to 275 A (AC-1) or 230 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz ), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
153 mm
Product Net Height
196 mm
Product Net Weight
3.3 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 55 °C 225 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 190 A | (440 V) 55 °C 190 A | (380 / 400 V) 55 °C 190 A | (220 / 230 / 240 V) 55 °C 190 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 250 A | (100 V) 1 Pole, 60 °C 250 A | (100 V) 1 Pole, 70 °C 200 A | (110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (175 V) 2 Poles in Series, 40 °C 250 A | (175 V) 2 Poles in Series, 60 °C 250 A | (175 V) 2 Poles in Series, 70 °C 200 A | (200 V) 2 Poles in Series, 40 °C 250 A | (200 V) 2 Poles in Series, 60 °C 250 A | (200 V) 2 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (260 V) 3 Poles in Series, 40 °C 250 A | (260 V) 3 Poles in Series, 60 °C 250 A | (260 V) 3 Poles in Series, 70 °C 200 A | (300 V) 3 Poles in Series, 40 °C 250 A | (300 V) 3 Poles in Series, 60 °C 250 A | (300 V) 3 Poles in Series, 70 °C 200 A | (350 V) 4 Poles in Series, 40 °C 250 A | (350 V) 4 Poles in Series, 60 °C 250 A | (350 V) 4 Poles in Series, 70 °C 200 A | (400 V) 4 Poles in Series, 40 °C 250 A | (400 V) 4 Poles in Series, 60 °C 250 A | (400 V) 4 Poles in Series, 70 °C 200 A | (72 V) 1-Pole, 40 °C 250 A | (72 V) 1-Pole, 60 °C 250 A | (72 V) 1-Pole, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A | (90 V) 1 Pole, 40 °C 250 A | (90 V) 1 Pole, 60 °C 250 A | (90 V) 1 Pole, 70 °C 200 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 250 A | (110 V) 2 Poles in Series, 60 °C 250 A | (110 V) 2 Poles in Series, 70 °C 200 A | (110 V) 3 Poles in Series, 40 °C 250 A | (110 V) 3 Poles in Series, 60 °C 250 A | (110 V) 3 Poles in Series, 70 °C 200 A | (220 V) 3 Poles in Series, 40 °C 250 A | (220 V) 3 Poles in Series, 60 °C 250 A | (220 V) 3 Poles in Series, 70 °C 200 A | (72 V) 2 Poles in Series, 40 °C 250 A | (72 V) 2 Poles in Series, 60 °C 250 A | (72 V) 2 Poles in Series, 70 °C 200 A | (72 V) 3 Poles in Series, 40 °C 250 A | (72 V) 3 Poles in Series, 60 °C 250 A | (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Operational Power AC-3e (Pe)
(415 V) 90 kW | (440 V) 110 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
15 W | at Rated Operating Conditions per Pole 15 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 250 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp | (200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 25 Hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 60 Hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 75 Hp | (550 ... 600 V AC) Three Phase 150 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
CB Certificate
SEMKO_SE-77322
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF190B..RT-AF205B-40...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF190B..RT-AF205B-40...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
166 mm
Package Level 1 Depth / Length
238 mm
Package Level 1 Height
180 mm
Package Level 1 Gross Weight
3.9 kg
Package Level 1 EAN
7320500510223
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature AF technology provides a wide control voltage range (250-500 V AC/DC), enabling stable operation across fluctuating networks and reducing panel energy waste. Business Impact This minimizes disturbances in motor starts, lowers energy consumption, and improves overall system reliability in heavy industry. Application Suitable for AC-1 and AC-3 motor control in conveyors, pumps, and fans in harsh industrial environments. Feature 4-pole main contacts plus 2 NO and 2 NC auxiliary contacts offer extended control capabilities without compromising enclosure space. Business Impact Enables easy circuit expansion and faster wiring in control panels, reducing install time and maintenance costs. Application Ideal for modular control schemes where add-on auxiliary blocks are required for complex start/stop logic. Feature Built–in surge protection provides an additional layer of protection against voltage spikes, reducing coil and contact wear. Business Impact Improves uptime and lowers spare parts consumption in facilities with irregular power quality. Application Suitable for compact panel installations thanks to a block-type design that supports easy stacking with other AF contactors. Feature Mechanical durability rated at 5 million operations with a maximum switching frequency of 300 cycles per hour. Business Impact Delivers long service life and predictable maintenance planning in continuous duty scenarios. Application Beneficial for high-cycle processes in manufacturing lines. Feature Coil control voltage options 250-500 V AC/DC with defined coil consumption (holding and pull-in) and power loss of 15 W per pole. Business Impact Ensures energy efficiency in coil drive and predictable thermal management in control cabinets. Application Compatible with standard terminal designs (bars) and normal industry dimensions for straightforward retrofit or panel integration. Feature Dimensions and weight 140 mm width, 153 mm depth, 196 mm height, 3.3 kg weight. Business Impact A compact footprint that fits standard enclosure layouts and minimizes panel footprint. Application Facilitates retrofits and upgrades in legacy automation installations.

Get a Quick Quote for a ABB 1SFL487262R1422

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL487262R1422? Enquire Now

FAQs

The AF190B-40-22RT-14 uses a 4-pole main circuit with bars for the main contacts and pre-mounted auxiliary contacts (2 NO and 2 NC). Wire the motor leads to the main terminals and connect the control circuit to the rated coil voltage (250-500 V AC/DC). The design supports add-on auxiliary contact blocks for expanded control logic, and its compact block-type form simplifies mounting in standard panels. Ensure alignment with UL/CSA and CE markings for the intended geography.
Main circuit rated operational voltage is 1000 V. AC-1 current at 1000 V ranges up to 250 A at 40–70 °C, and AC-3 current at 415–690 V is 190 A. DC-1, DC-3, and DC-5 ratings are specified for various configurations (e.g., up to 250 A in some DC arrangements). The device is designed for motor protection and control with a 4-pole configuration and 4 NO main contacts, along with protective surge features.
Yes. With 90 kW rated performance at higher voltages and robust mechanical durability, this 4-pole contactor is well-suited for conveyor belts, pumps, and similar load profiles in industrial automation. Its wide control voltage range and built‑in surge protection help maintain reliable starts and stops in environments with voltage fluctuations, improving line uptime and process stability.
The AF190B-40-22RT-14 block contactor carries CE declarations and UKCA compliance, with UL/CSA General Use ratings. It is RoHS compliant and supported by REACH declarations. This combination enables global deployment in regulated markets while ensuring safety and interoperability with standard control panels.
Key maintenance advantages include a mechanical durability specification of 5 million operations and a maximum switching frequency of 300 cycles per hour, reducing failure frequency in high-cycle applications. Built-in surge protection minimizes coil wear and external protection components, while modular add-on auxiliary blocks simplify future upgrades. Collectively, these factors shorten downtime and lower total cost of ownership in automation projects.