ABB 1SFL491074R8011 Contactor - CE/UL/IP40 Rated 690V

Part Number: 1SFL491074R8011
Manufacturer
ABB
Part number
1SFL491074R8011

Quick Summary

ABB 1SFL491074R8011 Contactor is a rugged motor control device for industrial machinery in harsh environments. Engineers often face reliability and downtime challenges when switching heavy loads at 690 V mains, making durable contactors essential. This unit carries CE and UL certifications and aligns with RoHS and IEC standards to support safe, compliant operation across global sites. Designed for straightforward installation and predictable performance, it supports standard mounting, compatible coil voltages, and reliable coil control. By combining high Ith ratings with compact dimensions, it delivers uptime, reduces service visits, and enhances overall motor protection in automation and electrical panels. Its 3-pole construction with 3NO and 1NO1NC auxiliaries supports flexible wiring and quick integration into starter assemblies.

Product Information

Extended Description

1SFL491074R8011 ABB: AX185-30-11-80 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 185~205A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
111.5 mm
Product Net Depth / Length
162.3 mm
Product Net Height
196 mm
Product Net Weight
3.2 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 250 A | (690 V) 55 °C 230 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 145 A | (500 V) 55 °C 145 A | (690 V) 55 °C 120 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 75 kW | (500 V) 90 kW | (690 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions per Pole 5 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Package Level 1 Units
box 1 piece
Package Level 1 Width
180 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
175 mm
Package Level 1 Gross Weight
3.8 kg
Package Level 1 EAN
7320500500255
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature – 3-pole block contactor with 3 NO main contacts and 1 NO plus 1 NC auxiliary contact. Business Impact – simplifies wiring, improves fault diagnosis, and provides clear signaling separation between main switching and auxiliary circuits. Application – ideal for motor starters in conveyors, pumps, and fans within industrial automation. Feature – Rated Operational Current AC-3 up to 185 A at 415 V and 120 A at 690 V in typical configurations. Business Impact – enables safe, reliable motor starting across a spectrum of voltages, reducing switching wear and extending service life. Application – suitable for large motors in packaging lines, material handling, and process equipment. Feature – Rated Insulation Voltage Ui of 690 V and Rated Impulse Withstand Voltage Ul of 8 kV. Business Impact – enhances protection margins against surges and ensures adherence to international insulation standards. Application – appropriate for control panels in high-energy environments. Feature – Mechanical Durability rated at 5 million cycles and Maximum Mechanical Switching Frequency of 3600 cycles per hour. Business Impact – delivers long life in high-cycle applications and supports faster maintenance cycles. Application – ideal for frequent start/stop drives in mining, cement, and water treatment. Feature – Coil Operating Limits compatible with 50 Hz 220–230 V and 60 Hz 230–240 V. Business Impact – simplifies procurement across regions with standardized coil voltages, reducing spare parts inventory. Application – globally deployed automation projects and multi-site rollouts. Feature – IP40 protection and Main Circuit Terminals configured as Bars. Business Impact – protects critical contacts from dust ingress while enabling robust, service-friendly wiring. Application – panel-mill installations, machine housings, and integrated control cabinets. Feature – Certifications including CE, UL, CCC, CQC, RoHS, REACH, TSCA. Business Impact – lowers regulatory risk and supports international supply chains. Application – medical, automotive, and industrial equipment manufacturing environments. Feature – Compact footprint with 111.5 mm width, 162.3 mm depth, 196 mm height and a net weight of 3.2 kg. Business Impact – saves enclosure space, facilitates dense panel layouts, and reduces shipping weight. Application – machine tool centers, packaging lines, and centralized motor starters. Feature – Main Circuit: Bars and Package Level 1 details with EAN 7320500500255. Business Impact – simplifies integration with bar-cued connections and enables efficient packaging and logistics. Application – OEM and system integrator deployments seeking consistent part handling.

Get a Quick Quote for a ABB 1SFL491074R8011

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL491074R8011? Enquire Now

FAQs

Install the device on a standard din rail or panel mounting that accommodates a 3-pole block contactor. Verify main circuit bars are correctly seated for 690 V operation, connect 3 NO main contacts and the 1 NO/1 NC auxiliary contact wiring, and ensure coil voltage matches the local supply (50 Hz 220–230 V or 60 Hz 230–240 V). Securely fasten with appropriate torque and verify insulation integrity before commissioning.
AC-3 rated Ie is up to 185 A at 415 V, and 145 A at higher voltages including 440–690 V, with a 55 °C ambient. It suits squirrel-cage induction motors that require switching with starting currents primarily during starting and stopping, such as pumps, fans, and conveyors in process automation.
Yes. The product is rated for Main Circuit 690 V and supports 60 Hz operation, with insulation voltage Ui at 690 V and an impulse withstand voltage of 8 kV, making it compatible with European and many international power networks.
The device carries CE and UL certifications along with CCC, CQC and RoHS/REACH declarations, plus TSCA. These mark compliance for safety, environmental, and cross-border procurement, reducing regulatory risk in global supply chains.
With a mechanical durability rating of 5 million cycles and a high Icw capability, the contactor minimizes downtime and maintenance visits. The compact design and reliable coil control reduce spare parts and installation time, contributing to lower total cost of ownership over the lifecycle of motor-driven equipment.