Quick Summary

The ABB 1SFL491074R8811 Contactor is a high‑capacity switch for three‑pole motor control in industrial drives. Engineers often struggle with undersized ratings and miswired panels, leading to costly downtime and failed startups. This block contactor carries CE declarations and UL certification, with 690 V insulation, 60 Hz operation, and robust thermal and short‑circuit ratings. Designed for ABB compatibility and easy panel integration, it delivers reliability, predictable maintenance, and lower total cost of ownership. Whether you're designing new equipment or upgrading legacy drives, the combination of performance and compliance supports faster commissioning and safer operation.

Product Information

Extended Description

1SFL491074R8811 ABB: AX185-30-11-88 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 185~205A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
111.5 mm
Product Net Depth / Length
162.3 mm
Product Net Height
196 mm
Product Net Weight
3.2 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 250 A | (690 V) 55 °C 230 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 145 A | (500 V) 55 °C 145 A | (690 V) 55 °C 120 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 75 kW | (500 V) 90 kW | (690 V) 110 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions per Pole 5 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Package Level 1 Units
box 1 piece
Package Level 1 Width
180 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
175 mm
Package Level 1 Gross Weight
3.8 kg
Package Level 1 EAN
7320500500262
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main NO contacts and auxiliary NO/NC contacts provide complete control and monitoring. Business Impact: ensures robust switching under AC‑3 duty with minimized wear, reducing maintenance costs and downtime. Application: three‑phase motor starters in conveyors, pumps, and machine tools. Feature: Rated insulation voltage of 690 V and coil compatibility for 50 Hz and 60 Hz supply. Business Impact: simplifies global sourcing and ensures safe operation across regional grids. Application: panel builders integrating equipment in diverse plant environments. Feature: Compact 3P design with auxiliary terminals IP40 and a weight of 3.2 kg. Business Impact: eases panel footprint, lowers heat density, and simplifies installation while preserving accessibility for testing. Application: space‑constrained control panels in automation lines. Feature: High mechanical durability (5 million cycles) and Rated Breaking/ Making Capacity (AC‑3 8 x Ie / 10 x Ie). Business Impact: delivers long service life and dependable startup/shutdown, lowering replacement cycles. Application: high‑duty motor control in packaging, material handling, and processing lines. Feature: Wide operating range (-25 to 70°C ambient; up to 3000 m altitude) and RoHS/REACH/TSCA compliance. Business Impact: ensures reliable operation in challenging environments with regulatory compliance. Application: industrial plants with varying climates and stringent sustainability requirements. Feature: Coil operating limits with 230–240 V at 50 Hz and 240–260 V at 60 Hz. Business Impact: supports universal installation across regions, reducing stocking complexity. Application: new builds and retrofits in global facilities.

Get a Quick Quote for a ABB 1SFL491074R8811

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL491074R8811? Enquire Now

FAQs

Install the 3P block contactor with main circuit connections using copper busbars and ensure proper clearance for heat dissipation. Mount the unit on a rigid panel surface, align auxiliary terminals for monitoring, and verify coil voltage (230–240 V at 50 Hz or 240–260 V at 60 Hz) matches your supply. Use factory wiring diagrams to connect the auxiliary NO/NC contacts for status feedback and interlocking as required.
For AC‑1 service at 690 V, the contactor supports up to 250 A at 40 °C, 230 A at 55 °C, and 180 A at 70 °C. For AC‑3 service, ratings vary by voltage: up to 185 A at 55 °C (with common configurations listed across 415–690 V categories) and related Pe values around 90–110 kW depending on voltage. These figures enable proper sizing for motor start/stop sequences in automation systems.
Yes, it is designed for 3‑phase motor control in industrial drives. Coil options include 230–240 V at 50 Hz and 240–260 V at 60 Hz, providing flexibility for regional power standards. The device supports reliable engagement with a low power loss of about 5 W per pole, helping to minimize heat in control cabinets and improve energy efficiency.
The block contactor carries CE declarations and UL certification, with RoHS and REACH compliance, and a CCC/ CQC presence for certain regions. Documentation covers safe operation, environmental compliance, and market approvals, making it suitable for global deployments in regulated industries.
With a mechanical durability rating of up to 5 million cycles and robust AC‑3/AC‑1 performance, you can expect long service life and reduced maintenance intervals. The compact footprint, low power loss, and predictable replacement cycles translate to lower total cost of ownership, especially in high‑duty conveyor, pump, and processing line applications.