ABB 1SFL497001R7200 Contactor - 690V 275A AC-3
Part Number: 1SFL497001R7200
Quick Summary
ABB 1SFL497001R7200 Contactor is a 3-pole DC-operated device used for motor starting in industrial drives. In practice, coil voltage tolerance and availability can drive costly downtime and panel rework. It carries CE, UL/CSA, and CCC certifications, backed by IEC 60947-4-1 and RoHS compliance, ensuring both safety and reliability. This solution integrates a robust 20–60 V DC control range with high insulation and compact footprint, delivering consistent performance in control panels and automation racks. For engineers and procurement teams, it translates to streamlined stocking, quicker installation, and long-term operating cost reductions in heavy-duty applications.
Product Information
Extended Description
1SFL497001R7200 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL487002R1100
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540923-7
Product Net Width
105 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
2.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 200 A | (1000 V) 55 °C 200 A | (1000 V) 70 °C 180 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (1000 V) 55 °C 95 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 132 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Power Loss
at Rated Operating Conditions per Pole 8 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 250 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69479
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CQC Certificate, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
cUL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CCC Declaration of Conformity, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20261-04HH
LOVAG Certificate
SE-0115106
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
178 mm
Package Level 1 Depth / Length
232 mm
Package Level 1 Height
167 mm
Package Level 1 Gross Weight
3.5 kg
Package Level 1 EAN
7320500338131
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: 3-pole design with DC control coil 20–60 V enables flexible, valve-to-motor control in standard automation cabinets; reduces wiring complexity and inventory while improving control reliability in conveyor drives and pump packages. Feature → High main circuit rating up to 690 V and 275 A AC-1 (and 185 A AC-3) delivers strong motor starting capability with minimal voltage drop, lowering downtime in fans, compressors, and extruders. Feature → Mechanical durability rated at 5 million cycles; business impact is extended service life and lower maintenance costs for mission-critical drives in mining, cement, and process industries. Feature → Short-circuit protection with gG fuses (160 A) provides a safer, code-compliant protection scheme, reducing risk of equipment damage and unplanned shutdowns. Feature → Comprehensive insulation and IP20 coil terminals with IP00 main terminals support safe, easy installation in standard panels, improving commissioning speed. Feature → Compact dimensions (105 mm W, 160 mm D, 196 mm H) and 2.9 kg weight enable lightweight, space-efficient installation in crowded control spaces. Feature → Clear installation torque and connection guidance (Main Circuit 18 N·m) ensures reliable electrical connections and repeatable performance across shifts and sites.
Get a Quick Quote for a ABB 1SFL497001R7200
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL497001R7200?
Enquire Now
FAQs
Ensure mounting on a flat, rigid surface and use the flat terminations supplied with screws and bolts for main poles. Adhere to the 18 N·m tightening torque for main circuits, and connect coil terminals with IP20 protection. Verify enclosure clearance and ambient temperature ranges (-25 to 50 C with/without thermal overload relay) to preserve insulation integrity and performance.
For AC-3 operation at 690 V, the rated operational current is 170 A (at 55 C). At 40 C it remains high for AC-1 ratings (275 A), while DC-1/DC-3 ratings at 110–220 V configurations also apply for specific pole arrangements. This provides robust motor control in variable-speed drives and heavy-duty conveyors.
Yes. The 20–60 V DC coil supports flexible control across standard automation panels, aligning with common PLC outputs and DC control schemes. This reduces wiring complexity, improves compatibility with existing drives, and lowers inventory variety while maintaining reliable coil operation under θ ≤ 70 C conditions.
It carries CE declarations of conformity and UL/CSA listings, along with CCC and several quality certificates (BV, GL, RINA, LR, DNV, and more as listed in the data set). RoHS compliance ensures restricted hazardous substances, and the product meets IEC 60947-4-1 for open contactors with broad environmental and safety certifications.
With a mechanical durability of 5 million cycles and a conservative 8 W per pole power loss, the device offers long service life and stable operating costs. The combination of IP protection, robust insulation, and reliable coil performance minimizes unplanned downtime in demanding environments such as mining, water treatment, and packaging plants.