ABB 1SFL497001R7222 Block Contactor - IEC 60947-4-1
Part Number: 1SFL497001R7222
Quick Summary
ABB 1SFL497001R7222 block contactor provides reliable motor starting in industrial drive systems. This device is designed for three-phase loads with DC control voltage, simplifying integration into modern automation architectures. Manufacturers often struggle with voltage compatibility, panel space, and long lead times when upgrading control gear, which can cause downtime and higher lifecycle costs. The unit is CE and UL/CSA certified with a Declaration of Conformity to IEC 60947-4-1, plus a broad set of global certificates that support safe global deployment. Its compact 3P design, 275 A main current capability at 690 V, and DC coil range of 20–60 V deliver robust performance across diverse applications. By aligning with ABB A-series compatibility and standard connection methods, it accelerates installation and reduces wiring complexity. This combination translates to reduced downtime and lower total cost of ownership for automation projects.
Product Information
Extended Description
1SFL497001R7222 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL487002R1122
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540923-7
Product Net Width
123.5 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
2.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 200 A | (1000 V) 55 °C 200 A | (1000 V) 70 °C 180 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (1000 V) 55 °C 95 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 132 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 355 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 320 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1000 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Power Loss
at Rated Operating Conditions per Pole 8 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 250 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69479
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CQC Certificate, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
cUL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden | CCC Declaration of Conformity, Contactor, AF145-30, AF145-30-11, AF145-30-22, AF185-30, AF185-30-11, AF185-30-22, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20261-04HH
LOVAG Certificate
SE-0115106
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
178 mm
Package Level 1 Depth / Length
232 mm
Package Level 1 Height
167 mm
Package Level 1 Gross Weight
3.5 kg
Package Level 1 EAN
7320500222737
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Three main NO contacts and two NO auxiliary contacts provide expanded control paths, enabling simultaneous motor starting and monitoring without increasing panel footprint. This design reduces wiring complexity and enables compact control schemes for 3P motors in conveyors, pumps, and processing lines, delivering faster installation and easier maintenance. The DC coil range of 20–60 V supports flexible integration with existing control architectures, lowering retrofit costs and enabling seamless upgrades in mixed-voltage environments. With 690 V main circuit capability and 275 A continuous rating at 40 °C, the device supports higher load profiles common in industrial drives, improving line throughput and reducing equipment stress. Insulation up to 1000 V and an 8 kV impulse withstand rating provide robust protection against transients, while IP20 coil terminals and IP00 main terminals simplify installation in controlled environments. The unit’s 123.5 mm net width, 160 mm depth, and 196 mm height, along with 2.9 kg weight, offer a practical balance of space efficiency and ruggedness. Bar terminal connections for main circuits and versatile auxiliary wiring support fast, reliable field commissioning, and standard connection practices align with typical ABB installation diagrams and dimension diagrams (53540923-7). These features collectively reduce commissioning time, enhance reliability, and lower lifecycle costs in manufacturing, packaging, and water treatment applications.
Get a Quick Quote for a ABB 1SFL497001R7222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL497001R7222?
Enquire Now
FAQs
Ensure proper mounting to meet the IP20 coil terminal and IP00 main terminal protection requirements. Use Bar 24 mm² or rigid Al/Cu cabling within 6–185 mm² for main and 0.75–2.5 mm² for auxiliary circuits. Adhere to tightening torque of 18 N·m on main terminals and consult dimension diagram 53540923-7 for precise clearance and mounting holes. The unit weighs 2.9 kg and fits within standard ABB panel layouts, reducing enclosure size impact.
At 690 V and 55–40 °C, the Rated Operational Current AC-3 is 170–185 A depending on ambient temperature, with a rated breaking capacity of 1600–2000 A cos φ. This confirms the device is suitable for motor starting and switching under typical AC-3 duty, providing robust short-time switching performance and protection against overload during motor starting sequences.
Yes. The product carries CE declarations of conformity and UL/CSA (including cUL) certifications, along with multiple other international certificates (BV, ABS, RINA, etc.). These certifications support compliance with global electrical safety, EMC, and performance standards, enabling safe deployment across regions and simplifying supplier qualification for regulated industries.
The coil operates on DC 20–60 V, with holding power of 2 W at rated voltage and pull-in power up to 500 W. This enables flexible wiring with existing DC control circuits, reduces coil losses in hold state, and supports faster response times during actuation in control panels and remote starter circuits.
Ideal for motor starting, isolation, bypass, and distribution in conveyors, pumps, and processing lines, the ABB 1SFL497001R7222 delivers reliable switching up to 690 V and 275 A. Benefits include higher installation efficiency, lower wiring complexity, improved uptime, and reduced lifecycle costs due to higher durability (5 million mechanical cycles) and broad compatibility with ABB automation platforms.