ABB 1SFL497063R6911 Block Contactor - IEC 60947-4-1
Part Number: 1SFL497063R6911
Quick Summary
ABB 1SFL497063R6911 is a 3-pole block contactor designed for rail applications, enabling robust motor switching in demanding environments. Designers often struggle with coil voltage compatibility and cross-application spares, which can drive up inventory and downtime. This device adheres to IEC/EN 60947-1, IEC/EN 60947-4-1 and UL 60947-4-1 standards, with CE marking for broad regulatory coverage and confidence in safety. Its wide coil control range of 48–130 V (AC or DC) simplifies integration across multiple drives, while the 690 V main circuit rating supports modern rail and industrial motor loads. The combination delivers reliable performance, reduced commissioning time, and lower total cost of ownership for maintenance and procurement teams.
Product Information
Extended Description
1SFL497063R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL487063R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540923-7
Product Net Width
111.5 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
3 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 200 A | (1000 V) 55 °C 200 A | (1000 V) 70 °C 180 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (1000 V) 55 °C 95 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 132 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Power Loss
at Rated Operating Conditions per Pole 8 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 250 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69479
CQC Certificate
CQC Certificate, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden
cUL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20261-04HH
LOVAG Certificate
SE-0115106
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
178 mm
Package Level 1 Depth / Length
232 mm
Package Level 1 Height
167 mm
Package Level 1 Gross Weight
3.6 kg
Package Level 1 EAN
7320500254899
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Wide coil control voltage range of 48–130 V AC/DC. Benefit: Simplifies cross-system wiring and spare parts management, reducing inventory costs and installation complexity in multi-drive rail applications. Application: Ideal for rail traction control panels and industrial drives requiring flexible coil compatibility. Feature: Three main contacts plus one NO auxiliary and one NC auxiliary. Benefit: More versatile switching sequences with built-in status signaling, lowering external relay count and improving startup sequencing in conveyor and lift systems. Application: Used in 3P motor circuits with auxiliary interlock in rail car control cabinets. Feature: Rated main voltage up to 690 V and multiple Ie ratings (AC-1, AC-3, DC-1, DC-3, DC-5). Benefit: Enables direct control of high-power motors with proven electrical life and predictable thermal performance. Application: Suitable for AC drive starters and feeder circuits in railway substations. Feature: Insulation voltage Ui up to 1000 V and impulse withstand 8 kV. Benefit: Strong insulation margins improve safety margins during switching transients, reducing arc risks and nuisance tripping. Application: Heavy-duty control circuits in demanding environments. Feature: Mechanical durability rating of 5 million operations. Benefit: Long service life reduces maintenance intervals and replacement costs in high-cycle applications. Application: Frequent switch operations in rolling stock or manufacturing lines. Feature: Compact footprint with main terminal options (bars or rigid cables) and 24 mm² to 185 mm² capacity. Benefit: Easier enclosure layout, faster wiring, and compatibility with common field-bus connections. Application: Panel builders and machine builders integrating with standardized bus bars. Feature: IP20 coil terminals and IP00 main terminals. Benefit: Clear separation of control and power sections with predictable ingress protection, simplifying testing and safety compliance. Application: Control cabinets in rail and industrial settings. Feature: Tightening torque of 18 N·m on main circuit terminals. Benefit: Ensures reliable, repeatable connections under vibration and thermal cycling. Application: Mechanical assemblies near rail vehicles or heavy equipment. Feature: 3P configuration with 3 NO main contacts and 1 NO/1 NC auxiliary. Benefit: Enables robust break/make and signaling paths for control logic and interlocking. Application: Safety interlocks and motor control in conveyors and hoists. Feature: Data-rich spec compatibility with industry standards (IEC/EN 60947-1, 60947-4-1; UL/CSA 60947-4-1). Benefit: Accelerates engineering validation and procurement across global facilities. Application: Global rail and industrial automation projects requiring certified components.
Get a Quick Quote for a ABB 1SFL497063R6911
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL497063R6911?
Enquire Now
FAQs
Yes. The coil operating limits cover 48–130 V (AC 50/60 Hz and DC), while the main circuit is rated up to 690 V. This combination supports standard railway control cabinets and motor drives, enabling straightforward integration with typical 3P power rails and locomotive or station equipment.
AC-3 Ie ratings include up to 185 A at 440–690 V and 170 A at several higher voltages, with DC-3 ratings at 275 A for applicable configurations. Practically, this means reliable switching for medium to large motors during starting and stopping sequences, with predictable thermal behavior under typical rail drive loads.
Absolutely. Its IEC/EN 60947-4-1, UL/CSA compliance, and 3P configuration make it suitable for rail traction systems, rolling stock control panels, and industrial drives requiring robust control of high-power motors, interlocks, and signaling circuits.
The device complies with IEC 60947-1 and IEC 60947-4-1, UL 60947-4-1, and CE marking, plus supporting certificates such as BV, GL, LR, LR for marine and other global standards. This broad certification suite supports global deployments with regulatory assurance.
The contactor features 24 mm² main terminals with 18 N·m tightening torque, compatible with rigid Al-Cu cables up to 185 mm², and IP20 coil terminals. This design simplifies wiring, reduces wobble during vibration, and minimizes maintenance downtime due to secure connections and durable mechanical life.