ABB 1SFL497063R7211 Contactor - IEC/EN 60947-4-1 Certified
Part Number: 1SFL497063R7211
Quick Summary
ABB 1SFL497063R7211 Contactor enables reliable motor starting and isolation in 3-phase plant applications. Engineers often struggle with coil voltage variability and mounting in tight switchgear, which leads to inventory overhead and wiring complexity. This device applies IEC/EN 60947-1 and 60947-4-1 alongside UL/ CSA certifications, ensuring compliance across regional panels and OEM configurations. With a wide control voltage range of 20 to 60 V DC and robust 690 V main circuit capability, it provides flexibility for varied drive systems. For panel builders and integrators, this translates to simpler stocking, faster installation, and safer, standards-aligned motor control in demanding environments.
Product Information
Extended Description
1SFL497063R7211 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL487063R1122
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540923-7
Product Net Width
111.5 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
3 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 200 A | (1000 V) 55 °C 200 A | (1000 V) 70 °C 180 A | (690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 185 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (1000 V) 55 °C 95 A | (380 / 400 V) 55 °C 185 A | (220 / 230 / 240 V) 55 °C 185
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A | (220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (1000 V) 132 kW | (380 / 400 V) 90 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Power Loss
at Rated Operating Conditions per Pole 8 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 24 mm² | Rigid Al-Cable 25 ... 150 mm² | Rigid Cu-Cable 6 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 250 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 50 hp | (208 V AC) Three Phase 50 hp | (220 ... 240 V AC) Three Phase 60 hp | (440 ... 480 V AC) Three Phase 125 hp | (550 ... 600 V AC) Three Phase 150 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 156 A | (550 ... 600 V AC) Three Phase 144 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69479
CQC Certificate
CQC Certificate, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden
cUL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF145, AF185, AF145B...RT, AF185B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20261-04HH
LOVAG Certificate
SE-0115106
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
178 mm
Package Level 1 Depth / Length
232 mm
Package Level 1 Height
167 mm
Package Level 1 Gross Weight
3.6 kg
Package Level 1 EAN
7320500254882
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3P block contactor features a wide control voltage range (DC 20–60 V) which reduces spare parts and simplifies wiring in mixed-control environments, delivering lower total cost of ownership for OEMs and service teams. This directly supports faster commissioning and easier maintenance in panel assemblies and machine retrofits. The device supports a high main-circuit rating up to 690 V and 50/60 Hz, enabling reliable motor starting for conveyors, pumps, and fans with diverse voltage requirements, improving uptime and energy management in process lines. With 3 NO main contacts and 1 NO + 1 NC auxiliary contacts, it offers straightforward interlocking and remote signaling for safer start/stop sequences and distributed control architectures. The protective envelope includes IP20 coil terminals and IP00 main terminals, easing installation through writable terminal access and reduced contamination risk in moderate environments. Its mechanical durability of 5 million cycles and a compact footprint help OEMs minimize panel depth and maintenance outages, while a tightening torque of 18 N·m ensures repeatable connections. The unit is rated for insulation up to 1000 V and Uimp of 8 kV, providing a substantial safety margin for switching transients in demanding industrial settings. Compatibility with standard data sheets and dimension diagrams accelerates replacement or upgrade projects, reducing downtime during plant modernization and spare parts management. With RoHS compliance and multiple international certifications (CE, UL/CSA, CCC, EAC, GL, RINA), it aligns with global procurement policies, enabling risk-managed sourcing and long-term supplier reliability. Field-installed options for 24 mm² to 185 mm² conductors support flexible wiring schemes, while the integrated auxiliary contacts facilitate advanced control logic and fault signaling in motor control centers and safety circuits. The device’s temperature range (−25 to 50 °C with thermal overload relay; −40 to 70 °C without) supports outdoor or semi-enclosed installations, expanding its applicability in industrial automation and material handling environments.
Get a Quick Quote for a ABB 1SFL497063R7211
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL497063R7211?
Enquire Now
FAQs
Yes. The unit is a 3-pole block contactor with a main circuit rated for up to 690 V and a control coil operable from 20 to 60 V DC. It supports 50/60 Hz operation and is designed for motor starting, isolation and distribution in 3‑phase systems. Connection options include bars and cables within a broad cross‑section range (24 mm² to 185 mm²), simplifying integration into existing switchgear.
The device provides rated operational current for AC‑3 up to 185 A at common voltages (e.g., 415–690 V) and a rated operation at various temperature points. It features a rated breaking capacity of up to 2000 A cos phi 0.45 at 440 V and 1600 A cos phi 0.45 at 690 V, with a mechanical durability of about 5 million cycles, suitable for demanding motor loads and frequent switching.
This ABB contactor complies with IEC/EN 60947‑1 and 60947‑4‑1, UL 60947‑4‑1, CSA C22.2, EN/CE declarations, and additional certifications such as CCC, GL, RINA, LR, and EAC where applicable. This broad certification footprint supports compliance in global projects and reduces compliance risk in multinational supply chains.
Main circuit terminals use bar connections with a tightening torque of 18 N·m and IP00 protection for main terminals, while coil terminals are IP20. The unit supports flexible and rigid conductor options: main circuit bars 24 mm², Cu/Al cables up to 150–185 mm², and auxiliary circuit connections for 0.75–2.5 mm² ferrule or solid conductors. This simplifies mounting, ensures reliable connections, and supports durable field installations.
The combination of a wide coil voltage range, high main-circuit voltage capability, and robust mechanical life reduces spare part inventories and downtime. With compact dimensions, integrated auxiliary contacts, and broad conductor compatibility, it accelerates installations and simplifies future upgrades. Certification coverage and RoHS compliance further minimize regulatory risk, delivering long-term reliability and lower total cost of ownership for industrial automation projects.