ABB 1SFL501074R8311 Block Contactor - UL CE 690V

Part Number: 1SFL501074R8311
Manufacturer
ABB
Part number
1SFL501074R8311

Quick Summary

ABB 1SFL501074R8311 Block Contactor is a high‑performing switching device for reliable motor control in industrial environments. Engineers often face the challenge of delivering robust protection while keeping control panels compact and maintainable. This model carries CE conformity, UL/cULus listing, and RoHS compliance, with a 690 V insulation rating to meet global safety standards. It combines a three‑pole main circuit with one auxiliary NO/NC contact, simplifying wiring and reducing panel depth. Compatible with standard motor protection components, it supports IEC 60947‑4‑1 applications and solid AC‑3 performance, delivering uptime and cost savings through fewer parts and faster assemblies.

Product Information

Extended Description

1SFL501074R8311 ABB: AX205-30-11-83 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 185~205A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
111.5 mm
Product Net Depth / Length
162.3 mm
Product Net Height
196 mm
Product Net Weight
3.2 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 205 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (380 / 400 V) 55 °C 205 A | (220 / 230 / 240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 59 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions per Pole 5 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Package Level 1 Units
box 1 piece
Package Level 1 Width
180 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
175 mm
Package Level 1 Gross Weight
3.8 kg
Package Level 1 EAN
7320500500309
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Three main NO contacts (3P) provide reliable power switching for three‑phase motors, enabling clean, synchronized start/stop sequences and reduced electrical noise. This translates to improved machine uptime and lower maintenance costs in manufacturing lines. Feature → 690 V insulation and 1000 V rating where applicable ensures compliance across global installations, minimizing rework when equipment is deployed internationally. Application: Suitable for high‑voltage motor control in packaging, extrusion, and process lines where regulatory adherence and long service life matter. Feature → Auxiliary NO/NC contact set (1 NO + 1 NC) supports integrated interlocking and signaling, simplifying control logic and reducing wire routing complexity. Application: Ideal for compact control panels in material handling and conveyance systems. Feature → AC‑3 rated performance (up to 205 A at 415 V, 170 A at 690 V) provides controlled motor starting with high mechanical durability, supporting long‑term production reliability. Application: Heavy‑duty conveyors and fans where frequent switching occurs. Feature → Mechanical durability of 5 million cycles and rated short‑time withstand current up to 1200 A (Icw) at 40 °C enables resilience under peak loads. Application: Critical in applications with intermittent peak demand like metalworking and plastics processing. Feature → Compact dimensions (111.5 mm width, 162.3 mm depth, 196 mm height) and weight around 3.2 kg facilitate easy installation and space optimization in control cabinets. Application: Ideal where panel space is constrained and retrofit projects require minimal footprint impact. Feature → Broad compatibility with standard motor starters, overload relays, and protective devices (DIN rail or panel mounting), streamlining procurement and reducing project lead times. Application: OEMs and system integrators benefit from faster commissioning and consistent performance across machines.

Get a Quick Quote for a ABB 1SFL501074R8311

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL501074R8311? Enquire Now

FAQs

The 1SFL501074R8311 is a three‑pole block contactor designed for main circuits up to 1000 V insulation and 690 V rated operation. It features a main circuit with bars for terminals and an auxiliary NO/NC contact, allowing straightforward wiring and reliable integration with standard overload relays and motor starters in 50 Hz environments.
AC‑3 ratings vary by voltage: at 415 V, Ie is 205 A with a corresponding Po ≈ 110 kW; at 690 V, Ie is 170 A with Po ≈ 132 kW. The device also supports up to 8 x Ie as rated breaking capacity and up to 10 x Ie for making capacity, enabling controlled motor starting for heavy loads.
Yes. The contactor is designed for compatibility with common ABB motor protection components and is listed with CE declarations, UL/cULus certification, and RoHS compliance. This ensures reliable operation across global markets and simplifies regulatory documentation in panel builds.
The unit uses main circuit bars for terminals and has compact dimensions: 111.5 mm width, 162.3 mm depth, and 196 mm height, with an approximate net weight of 3.2 kg. Plan for panel space, proper ventilation, and ensure ambient temperatures remain within −25 to 70 °C depending on nearby relay configurations to avoid derating.
With a mechanical durability of about 5 million cycles and a low coil power loss (~5 W per pole), you gain reduced maintenance intervals and lower energy consumption. The built‑in auxiliary contact supports simpler wiring and diagnostics, shortening replacement time and improving system availability, which translates into tangible operating expense savings.