ABB 1SFL501074R8611 Block Contactor - CE UL CCC

Part Number: 1SFL501074R8611
Manufacturer
ABB
Part number
1SFL501074R8611

Quick Summary

ABB 1SFL501074R8611 Block Contactor is a high‑capacity motor switching device designed for robust motor protection and control in industrial automation. This unit helps engineers avoid undersized contacts and thermal overload by delivering rated AC-3 performance at up to 690 V and 170 A in typical 55 °C environments. It is CE, UL, and CCC certified, with RoHS and REACH compliance to support global procurement and regulatory audits. The compact 3P design fits standard control cabinets and supports scalable motor protection and control solutions for conveyors, pumps, and fans in manufacturing environments.

Product Information

Extended Description

1SFL501074R8611 ABB: AX205-30-11-86 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 185~205A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
111.5 mm
Product Net Depth / Length
162.3 mm
Product Net Height
196 mm
Product Net Weight
3.2 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 275 A | (690 V) 55 °C 250 A | (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 205 A | (440 V) 55 °C 185 A | (500 V) 55 °C 170 A | (690 V) 55 °C 170 A | (380 / 400 V) 55 °C 205 A | (220 / 230 / 240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 90 kW | (500 V) 110 kW | (690 V) 132 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 59 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Power Loss
at Rated Operating Conditions per Pole 5 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX185, AX205, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A145...A185, AX185...AX205
Package Level 1 Units
box 1 piece
Package Level 1 Width
180 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
175 mm
Package Level 1 Gross Weight
3.8 kg
Package Level 1 EAN
7320500500354
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Three-pole block contactor with 3 main NO and 1 auxiliary NC contacts enables reliable switching for motor loads, reducing wiring complexity and panel space. This translates to faster installations and easier maintenance in conveyors, pumps, and fans across manufacturing lines. Feature → Business Impact → Application: AC-3 rated current up to 170 A at 690 V and AC-1 up to 275 A at 690 V aligns with typical starting and running currents, minimizing derating in demanding duty cycles and improving drive efficiency in equipment like mixers and material handlers. Feature → Business Impact → Application: Rated insulation voltage of 690 V and coupling to 400/415/440 V control circuits supports seamless integration with existing industrial controls, enabling plug‑and‑play compatibility in new lines or plant retrofits. Feature → Business Impact → Application: Mechanical durability of 5 million cycles and a maximum of 3600 mechanical switching cycles per hour lowers replacement frequency and downtime in high‑duty plants, boosting overall line uptime. Feature → Business Impact → Application: RoHS, REACH and CMRT compliance reduce regulatory risk and enable supply from global plants, while CE/UL/CCC certification ensures market acceptance in Europe, North America, and Asia for construction and retrofits.

Get a Quick Quote for a ABB 1SFL501074R8611

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL501074R8611? Enquire Now

FAQs

This three‑pole contactor uses main circuit bars for the primary connection and supports a 1000 V insulation rating. It fits standard control cabinets and is designed for 690 V DC/AC motor circuits, with room for a compatible thermal overload relay. Ensure panel space allows for 111.5 mm width by 162.3 mm depth and that ambient temperature stays within the -25 to 70 °C range for reliable operation.
The unit provides AC-3 current ratings of 170 A at 690 V (55 °C) and 205 A to 170 A across other voltage options, enabling it to handle typical motor starting and switching loads without excessive derating in moderate environments.
Yes. With 3P poles and 3 main NO contacts plus 1 auxiliary contact, it is ideal for three-phase motor control in conveyors, pumps, and fans. Its 690 V insulation and 60 Hz compatibility align with standard industrial power baselines used in material handling and process lines.
The device carries CE, UL (cULus), and CCC declarations, along with RoHS and REACH compliance, ensuring regulatory readiness for European, North American, and Asian markets and simplifying supplier qualification and audits.
Its mechanical durability of 5 million cycles and 3,000+ hours of panel uptime minimize maintenance intervals, while compact dimensions and RoHS/REACH compliance reduce waste, energy use, and compliance risk—delivering lower total cost of ownership in high‑volume production environments.