Block Contactor ABB 1SFL517063R6911 - 690V, 48–130V Coil, CE/UL/CSA Certified
Part Number: 1SFL517063R6911
Quick Summary
Block Contactor ABB 1SFL517063R6911 is a rugged 3-pole AC/DC coil-controlled switch designed for railway and heavy-duty industrial drives. Engineers frequently face control-voltage constraints and reliability issues in harsh environments; this device addresses those pains with a wide 48–130 V coil range and fast operating times. It carries IEC/EN 60947-1, IEC 60947-4-1, UL/CSA, and CE certifications, offering proven compliance for railways, mining, and heavy plant installations. With compact dimensions (140 × 180.5 × 227 mm) and a weight of 5.5 kg, it fits tight electrical rooms while delivering dependable performance and reduced lifecycle costs. In addition, its robust construction supports long-term uptime in demanding settings, making it a solid choice for industrial automation and railway applications.
Product Information
Extended Description
1SFL517063R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL527063R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.5 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 350 A | (690 V) 55 °C 300 A | (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 210 A | (440 V) 55 °C 210 A | (500 V) 55 °C 210 A | (690 V) 55 °C 210 A | (380 / 400 V) 55 °C 210 A | (220 / 230 / 240 V) 55 °C 210
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 110 kW | (500 V) 132 kW | (690 V) 160 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 59 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 9 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 300 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 60 hp | (208 V AC) Three Phase 60 hp | (220 ... 240 V AC) Three Phase 75 hp | (440 ... 480 V AC) Three Phase 150 hp | (550 ... 600 V AC) Three Phase 200 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 180 A | (550 ... 600 V AC) Three Phase 192 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69491
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115198
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
TÜV Certificate
MHM-EST-7.70017788e
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
6.2 kg
Package Level 1 EAN
7320500258439
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main NO contacts plus one NO and one NC auxiliary contact. Benefit: Enables reliable three‑phase switching with integrated interlock/feedback signals, reducing panel wiring and enabling compact control logic for conveyors, fans, and drive systems. Application: Ideal for rail and heavy-duty industrial drives where space and reliability matter. Feature: Coil voltage range 48–130 V AC/DC. Benefit: Simplifies control architecture and stock management by supporting both AC and DC control with a single device. Application: Suitable for mixed-voltage servo and traction control environments. Feature: Rated main circuit voltage up to 690 V and substantial current paths. Benefit: Supports high-power motor start and load switching with proven performance across voltage classes, minimizing downtime and spare parts. Application: Rail traction, conveyors, and large fans with frequent starting. Feature: Connecting capacity and terminal design. Benefit: Main circuit bars up to 32 mm² and rigid cables up to 240 mm², with flat terminals and 18 N·m tightening torque, enabling quick, secure installations. Application: Panel builders and service technicians deploying harsh-duty systems. Feature: Environmental and safety ratings. Benefit: IP20 coil terminals and IP00 main terminals, with broad operating temperature ranges and IEC/UL/CSA certifications, delivering reliable operation in locomotive yards and plant floors. Application: Industrial automation in environments with temperature swings and vibration. Feature: Durability and lifecycle. Benefit: Mechanical durability of 5 million cycles and documented fault-tolerant switching frequencies, reducing maintenance needs and extending mean time between failures. Application: Long-life drive control in continuous operation settings.
Get a Quick Quote for a ABB 1SFL517063R6911
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL517063R6911?
Enquire Now
FAQs
Yes. The coil accepts 48–130 V for both AC and DC operation, with a control-voltage range specified as 0.85 x Uc to 1.1 x Uc depending on ambient temperature. This supports consistent performance across 50 Hz and 60 Hz supply conditions in rail and industrial applications. The wide range also simplifies stocking and control-system integration.
The device uses 3 main normally-open (NO) contacts plus 1 NO auxiliary contact and 1 NC auxiliary contact. At 690 V, the rated operational current is 350 A for AC-1 (40 °C), 300 A (55 °C), and 240 A (70 °C). For AC-3 duty, it delivers 210 A across typical 440–690 V ranges, with 8 x Ie breaking capacity and 10 x Ie making capacity in relevant conditions.
Yes, it is designed for railway and heavy industrial use with a broad safety and performance envelope. It conforms to IEC 60947-1 and IEC 60947-4-1, UL 60947-4-1, CSA C22.2, CE declarations, and other certifications listed in the datasheet, including additional approvals for rail and vehicle applications. This helps ensure regulatory compliance and safe interoperability in transit ecosystems.
Main-circuit connections use bars up to 32 mm² or rigid Cu/Al cables, with conducting capacity up to 240 mm². Terminal type is main circuit bars, and auxiliary connections support flexible and ferrule terminations. Tightening torque for main terminals is 18 N·m. Overall dimensions are 140 mm W × 180.5 mm D × 227 mm H, and the weight is 5.5 kg, which informs panel space planning and mounting clearances.
The device offers a mechanical durability of 5 million cycles and supports high switching frequency for AC-1, AC-2, and AC-3 responsibilities. With robust environmental ratings (IP20 for coil terminals and IP00 for main terminals) and wide operating temperatures, it reduces maintenance cycles, improves uptime, and lowers total cost of ownership in continuous-operation automation and rail-drive systems.