ABB 1SFL517063R7011 Block Contactor - EN 50155

Part Number: 1SFL517063R7011
Manufacturer
ABB
Part number
1SFL517063R7011

Quick Summary

ABB 1SFL517063R7011 Block Contactor is a reliable 3-pole switch designed for heavy rail and industrial applications. This device addresses the common challenge of needing compact, robust control in demanding environments where downtime is costly. It complies with key standards such as IEC/EN 60947-4-1, UL 60947-4-1, and EN 50155, ensuring railway suitability and cross-border acceptability. With a wide coil control range of 100–250 V and a main circuit rated up to 690 V, it supports both AC and DC control schemes. By combining high current capability with proven safety certifications, this contactor delivers predictable performance, easier procurement, and streamlined maintenance for your rail and manufacturing systems.

Product Information

Extended Description

1SFL517063R7011 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL527063R1322
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 350 A | (690 V) 55 °C 300 A | (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 210 A | (440 V) 55 °C 210 A | (500 V) 55 °C 210 A | (690 V) 55 °C 210 A | (380 / 400 V) 55 °C 210 A | (220 / 230 / 240 V) 55 °C 210
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 110 kW | (500 V) 320 kW | (690 V) 160 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 59 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 9 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 18 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 300 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 60 hp | (208 V AC) Three Phase 60 hp | (220 ... 240 V AC) Three Phase 75 hp | (440 ... 480 V AC) Three Phase 150 hp | (550 ... 600 V AC) Three Phase 200 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 180 A | (550 ... 600 V AC) Three Phase 192 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69491
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115198
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.75 kg
Package Level 1 EAN
7320500356456
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: 3P main contact arrangement plus 1 auxiliary NO and 1 NC contact delivers versatile control for motor loads and signaling circuits, reducing the need for additional relays and simplifying wiring. This translates to lower installation time and improved reliability in rolling stock assemblies and plant automation. Feature → Business Impact → Application: Wide control voltage 100–250 V AC/DC enables a single stock of coils to cover multiple control schemes, cutting spare parts costs and simplifying inventory for procurement teams in rail yards and industrial facilities. Feature → Business Impact → Application: Main circuit rated up to 690 V and AC-3 current ratings up to 210 A at various temperatures provide robust motor switching for fans, pumps, and conveyor drives in rail maintenance depots and processing lines. Feature → Business Impact → Application: Mechanical durability rated at 5 million cycles and a maximum operating frequency of 300 cycles/hour offer long service life under challenging duty cycles, reducing downtime and lifecycle costs for switchgear in substations and on-board systems. Feature → Business Impact → Application: Dimensioned for standard mounting with 32 mm² busbars and compatible cables (16–240 mm²), plus a tightening torque of 18 N·m, ensures straightforward installation and secure connections in confined control panels and traction equipment. Feature → Business Impact → Application: IP20 coil terminals and IP00 main terminals, along with broad compliance (IEC/EN 60947-4-1, UL 60947-4-1, EN 50155), provide rugged operation in glare-prone, vibration-prone railway environments, improving uptime and safety margins in signaling cabinets and traction control panels. Feature → Business Impact → Application: 9 W per pole power loss and coil current/power data support optimized control strategies, enabling energy-aware control schemes and better thermal management in compact control enclosures. Feature → Business Impact → Application: Data-rich certifications (BV, GL, RINA, EAC, CCC, CE, UL/CSA) support global project deployment and customer audits, reducing certification timelines for rail projects and large-scale industrial installations.

Get a Quick Quote for a ABB 1SFL517063R7011

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL517063R7011? Enquire Now

FAQs

The block contactor supports Bar 32 mm² main connections and rigid or flexible cables from 16 to 240 mm². Use the recommended tightening torque of 18 N·m on main terminals, and ensure connectors are clean and free of oxidation. The footprint is compatible with common 3P assemblies, simplifying panel layout and reducing assembly time.
For AC-3 at 690 V and 55 °C, the rated operational current Ie is 210 A. The device also supports high breaking and making capacities (8 x Ie and 10 x Ie respectively) and a maximum switching rate of up to 300 cycles per hour, enabling reliable motor starting and control in demanding rail and industrial loads.
Yes, it is suitable for railway use. The product references EN 50155 for applicable parts and is designed to meet IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1 and other global standards. Additional declarations cover CE, CCC, EAC, GL, LR, RINA, and BV certifications, supporting compliance in multinational rail projects.
The ABB contactor comes with a broad range of certificates and declarations including CE, CCC, EAC, BV, GL, LR, RINA, RMRS, and UL/CSA approvals. It also references EN 50155 for railway relevance and multiple IEC/UL standards for electrical safety and performance, reducing qualification time for international tenders.
With a mechanical durability of 5 million cycles and a robust design for frequent switching, downtime is minimized and maintenance intervals can be extended. The device’s wide operating voltage and compatibility with standard termination methods lower spare parts inventory, while certifications simplify installation in mixed-use rail and industrial environments.