ABB AF205-30-00-32 Block Contactor - UL/CSA 1000 V
Part Number: 1SFL527002R3200
Quick Summary
Block Contactor AF205-30-00-32 provides reliable motor control for three-phase drives in industrial machinery. In practice, control voltage variability can cause chatter or nuisance trips, especially in unstable networks. This ABB device carries CE, UKCA, and UL/CSA certifications to meet global safety and performance standards. AF technology delivers a wide control-voltage range and built-in surge protection, helping lower panel energy use while preserving fast, reliable switching. Designed for 110 kW motor control at 400 V AC in AC-3 circuits, it supports easy expansion via auxiliary contact blocks. Its robust construction minimizes downtime and total cost of ownership in demanding manufacturing environments.
Product Information
Extended Description
1SFL527002R3200 ABB: The AF205-30-00-32 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 110 kW / 400 V AC (AC-3) or 150 hp / 480 V UL and switching power circuits up to 350 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
105 mm
Product Net Depth / Length
165.5 mm
Product Net Height
196 mm
Product Net Weight
2.4 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 275 A | (1000 V) 60 °C 250 A | (1000 V) 70 °C 200 A | (690 V) 40 °C 350 A | (690 V) 60 °C 300 A | (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 205 A | (440 V) 60 °C 205 A | (500 V) 60 °C 186 A | (690 V) 60 °C 165 A | (1000 V) 60 °C 100 A | (380 / 400 V) 60 °C 205 A | (220 / 230 / 240 V) 60 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 132 kW | (500 V) 132 kW | (690 V) 160 kW | (1000 V) 132 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 2 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 2 W | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 25 W | at Rated Operating Conditions AC-3 per Pole 8 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 50 ... 95 mm² | Rigid Al-Cable 1 x 95 ... 185 mm² | Rigid Cu-Cable 1 x 6 ... 150 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M8 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 18 N·m | Control Circuit 1 N·m | Main Circuit 14 ... 31 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 275 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 60 hp | (220 ... 240 V AC) Three Phase 75 hp | (440 ... 480 V AC) Three Phase 150 hp | (550 ... 600 V AC) Three Phase 200 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 301 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 177 A | (220 ... 240 V AC) Three Phase 192 A | (440 ... 480 V AC) Three Phase 180 A | (550 ... 600 V AC) Three Phase 192 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF190-30, AF205-30, AFS190-30, AFS205-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
160 mm
Package Level 1 Depth / Length
258 mm
Package Level 1 Height
235 mm
Package Level 1 Gross Weight
3 kg
Package Level 1 EAN
7320500561744
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Three-pole design with 1000 V main circuit rating delivers robust motor switching for demanding drives, reducing downtime and enabling reliable operation in conveyors and pumps. AF technology provides a wide control-voltage range (48–130 V AC/DC) which tolerates voltage swings without nuisance tripping, cutting energy waste in unstable networks. Built-in surge protection and a compact block-type design simplify panel layout and enable quick expansion with add-on auxiliary contact blocks, improving scalability for evolving automation needs. The contactor’s 3P configuration with 3 NO main contacts ensures straightforward wiring for standard motor starters, while the bars main-circuit terminals streamline installation in control panels and switchgear. High electrical endurance, with up to 5 million mechanical cycles, reinforces long-term reliability in continuous process environments. Installation is facilitated by clear connection options for flexible and rigid conductors, reducing commissioning time and installation errors.
Get a Quick Quote for a ABB 1SFL527002R3200
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL527002R3200?
Enquire Now
FAQs
Install using main circuit bars with the 3P layout, ensure coil terminals are IP20 protected, and use the recommended M8 fasteners for the main circuit. Adhere to torque specs of 14–31 N·m for main circuit connections and 1 N·m for auxiliary circuits. Plan for a 9 mm wire stripping length on auxiliary and control circuits, and place the unit within the -25 to 55 °C operating range for optimal performance.
AC-1 rated operational current (Ie) is up to 275 A at 1000 V and 250 A at 1000 V with 60 °C ambient, while AC-3 Ie is up to 205 A at 415–690 V. Rated power for AC-3 reaches up to 160 kW at 690 V (varies with voltage). The device supports up to 8 x Ie for breaking capacity in AC-3 and a 3-pole 3 NO main contact configuration.
Yes. The AF205-30-00-32 is rated for operation up to 3000 meters without derating. Ambient temperature ranges extend from -25 °C to 55 °C (with an optional thermal overload relay variant) and up to -40 °C to 70 °C for storage, making it versatile for alpine or elevated industrial facilities.
The device carries CE and UKCA conformity declarations and UL/CSA certification. These approvals validate compliance with European, UK, and North American safety and performance standards, easing procurement for global projects and helping customers meet regulatory requirements in diverse markets.
The AF205-30-00-32 delivers energy-efficient operation via AF technology and a wide control-voltage range that reduces panel energy waste. Built-in surge protection lowers the risk of damage from voltage spikes, while 5 million mechanical cycles indicate long service life and reduced maintenance. Its compatibility with add-on auxiliary blocks simplifies future expansion, improving overall system uptime and return on investment.