ABB 1SFL527102R1100 Block Contactor - 1000 V IEC/UL Rated
Part Number: 1SFL527102R1100
Quick Summary
Block Contactor ABB 1SFL527102R1100 enables reliable motor control in industrial automation panels. In practice, voltage sags and surges in uneven power networks can cause nuisance trips and unreliable starts. CE, UL/CSA, and RoHS certifications underpin global compliance while IP ratings and robust coil protection enhance safety and reliability. By leveraging AF technology and a compact footprint, this device supports scalable control with modular expansion options, helping reduce panel wiring, energy waste, and maintenance costs in demanding environments.
Product Information
Extended Description
1SFL527102R1100 ABB: The AF205-40-00-11 is a 4 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 110 kW / 400 V AC (AC-3) / and switching power circuits up to 350 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF190,AF205
Product Net Width
140 mm
Product Net Depth / Length
152.5 mm
Product Net Height
196 mm
Product Net Weight
3.3 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A | (1000 V) 60 °C 225 A | (1000 V) 70 °C 185 A | (690 V) 40 °C 350 A | (690 V) 60 °C 250 A | (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 205 A | (440 V) 55 °C 205 A | (380 / 400 V) 55 °C 205 A | (220 / 230 / 240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 132 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 400 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 205 W
Power Loss
25 W | at Rated Operating Conditions per Pole 25 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Main Circuit
Flexible 2 x 50 ... 95 mm² | Rigid Al-Cable 1 x 95 ... 185 mm² | Rigid Cu-Cable 1 x 6 ... 150 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 18 N·m | Main Circuit 14 ... 31 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 275 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 Hp | (200 V AC) Three Phase 60 hp | (208 V AC) Three Phase 60 hp | (220 ... 240 V AC) Three Phase 30 Hp | (220 ... 240 V AC) Three Phase 75 hp | (440 ... 480 V AC) Three Phase 75 Hp | (440 ... 480 V AC) Three Phase 150 hp | (550 ... 600 V AC) Three Phase 100 Hp | (550 ... 600 V AC) Three Phase 200 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-77322
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF190-40, AF205-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
166 mm
Package Level 1 Depth / Length
238 mm
Package Level 1 Height
180 mm
Package Level 1 Gross Weight
3.9 kg
Package Level 1 EAN
7320500503782
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707195
Feature → 4-pole main switch with main circuit bars supports high-current motor control, providing a robust foundation for heavy machinery and conveyors in automated lines. Business Impact → Improves uptime and reduces panel footprint, enabling tighter control enclosures and simpler wiring. Application → Suitable for motor starters and power circuits in manufacturing lines where 110 kW AC-3 performance is needed at 400/415 V. Feature → Wide control circuit range 24-60 V AC and 20-60 V DC coil operation. Business Impact → Minimizes control voltage sensitivity, reduces energy waste, and lowers risk of misoperation in networks with voltage fluctuations. Application → Ideal for systems with variable control voltages and remote control requirements. Feature → Built-in surge protection and AF technology. Business Impact → Extends coil life, lowers maintenance, and enhances reliability in harsh electrical environments. Application → Beneficial in OEM machines and process lines where supply quality fluctuates. Feature → Modular design with add-on auxiliary contact blocks. Business Impact → Scales I/O without redesigning panels, saving integration time. Application → Quick customization for machine neighborhoods or multi-motor control. Feature → Comprehensive ratings and environmental specs. Business Impact → Ensures compliance and predictable performance across temperature, altitude, and duty cycles. Application → Global deployments with CE/UL/ RoHS and environmental declarations.
Get a Quick Quote for a ABB 1SFL527102R1100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL527102R1100?
Enquire Now
FAQs
The 4P block contactor uses main circuit bars for wiring, with IP20 coil terminals and IP00 main terminals. Ensure the panel clearance matches the 140 mm width and 196 mm height, secure connections to the specified 2 x 50–95 mm² flexible or rigid Cu/Al cables, and follow the AF technology mounting guidelines for proper alignment and maintainable auxiliary block add-ons.
Coil options span 24–60 V AC (50/60 Hz) and 20–60 V DC. This wide range accommodates control voltage variations and reduces misoperation in unstable networks. Coil consumption varies by mode, with pull-in and holding values designed to minimize power draw while ensuring fast, reliable operation.
The model carries CE and UL/CSA documentation, RoHS and REACH declarations, and EAC-related references, supporting global regulatory compliance. These certifications reassure customers that the device meets essential safety, environmental, and performance standards for international installations.
AC-3 ratings include up to 205 A at 415–440 V and 205 A at 380–400 V, with motor power switching up to 110 kW at 415 V. AC-1 ratings show 250 A at 1000 V (40–60 °C) and related current deratings. These figures support reliable motor starting and control in heavy-duty applications.
AF technology delivers a wide control voltage range and a compact, modular design that reduces panel space and wiring. The built-in surge protection lowers coil wear and maintenance costs, while add-on auxiliary blocks simplify I/O expansion, delivering faster deployment and improved total cost of ownership in manufacturing environments.