ABB 1SFL527102R1411 Block Contactor - CE/UL 1000V
Part Number: 1SFL527102R1411
Quick Summary
Block Contactor 1SFL527102R1411 by ABB provides reliable motor control for 110 kW drives at 400 V AC. Engineers often face control voltage variations and energy waste in panels, especially in unstable networks. This AF technology block offers a wide control voltage range, built-in surge protection, and a compact footprint, while meeting essential safety standards. With pre-mounted auxiliary contacts and main circuit bars, it simplifies wiring and reduces panel depth. The device is CE and UL listed, ensuring compliance across European and North American facilities. By selecting this ABB solution, teams gain predictable operation, lower energy losses, and easier maintenance through modular add-ons and straightforward commissioning.
Product Information
Extended Description
1SFL527102R1411 ABB: The AF205-40-11-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 110 kW / 400 V AC (AC-3) / and switching power circuits up to 350 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF190,AF205
Product Net Width
140 mm
Product Net Depth / Length
152.5 mm
Product Net Height
195.6 mm
Product Net Weight
3.3 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 275 A | (1000 V) 60 °C 250 A | (1000 V) 70 °C 200 A | (690 V) 40 °C 350 A | (690 V) 60 °C 300 A | (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 205 A | (440 V) 55 °C 205 A | (380 / 400 V) 55 °C 205 A | (220 / 230 / 240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW | (440 V) 132 kW | (380 / 400 V) 110 kW | (220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 400 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage DC 3.9 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
at Rated Operating Conditions per Pole 25 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Main Circuit
Flexible 1 x 6 ... 120 mm² | Rigid Al-Cable 1 x 95 ... 185 mm² | Rigid Cu-Cable 1 x 6 ... 150 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 18 N·m | Main Circuit 14 ... 31 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 275 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 Hp | (200 V AC) Three Phase 60 hp | (208 V AC) Three Phase 60 hp | (220 ... 240 V AC) Three Phase 30 Hp | (220 ... 240 V AC) Three Phase 75 hp | (440 ... 480 V AC) Three Phase 75 Hp | (440 ... 480 V AC) Three Phase 150 hp | (550 ... 600 V AC) Three Phase 100 Hp | (550 ... 600 V AC) Three Phase 200 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF190-AF205 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 35 %
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-77322
CQC Certificate
CQC Certificate, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF190-*-*-*, AF205-*-*-*, AF190B-*-*-*, AF205B-*-*-*, AFS190-30-*-*, AFS205-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF190-40, AF205-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
166 mm
Package Level 1 Depth / Length
238 mm
Package Level 1 Height
180 mm
Package Level 1 Gross Weight
3.9 kg
Package Level 1 EAN
7320500503690
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707217
E-Number (Norway)
3210337
E-Number (Sweden)
3210337
Feature → Business Impact → Application: 4P AF technology with a wide coil voltage range (250-500 V AC/DC) enables operation across fluctuating control networks, reducing nuisance trips and energy waste; benefits include improved panel energy efficiency and stable motor start-up in variable power conditions, ideal for heavy-duty conveyors and pumps. Feature → Built-in surge protection provides robust protection against voltage spikes, minimizing contactor wear and failure rates in harsh industrial environments; application includes steel mills and chemical plants where transients are common, reducing downtime and maintenance costs. Feature → Pre-mounted auxiliary contacts NO/NC and Main Circuit Bars simplify wiring and enable fast, plug-and-play installation on new builds or retrofits; application covers HVAC systems and processing lines requiring quick upgrades with minimal panel redesign. Feature → 4 pole, 1000 V rated main circuit supports high-power motors up to 110 kW at 400 V AC (AC-3) with UP to 350 A AC-1; this translates to higher starting torque and smoother control for fans, pumps, and extrusion lines. Feature → Wide operating temperature and mechanical durability offer reliability in ambient conditions up to 50 °C and 5 million mechanical cycles, delivering long service life in automotive and packaging lines. Feature → Compact form factor (140 mm width, 152.5 mm depth, 195.6 mm height, 3.3 kg) reduces panel footprint and enables easier integration with existing cabinets, while offering compatible add-on accessory blocks for future expansion.
Get a Quick Quote for a ABB 1SFL527102R1411
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL527102R1411?
Enquire Now
FAQs
Install with Main Circuit Bars and use Flexible 1 x 6 ... 120 mm² cables or rigid Cu/Al conductors as specified. Connect auxiliary NO/NC contacts as required, tighten main terminals to 14–31 N·m, and apply a coil supply within the 250–500 V range (AC or DC) per IEC 60947-4-1. Verify ambient temperature is within -25 to 50 °C and ensure IP20 protection on coil terminals.
The coil operating limits cover 50 Hz 250–500 V, 60 Hz 250–500 V, and DC 250–500 V. Holding and pull-in currents are specified in the datasheet, ensuring stable operation across voltage variations typical in industrial networks.
Yes. Rated Operational Power AC-3 is 110 kW at 415 V (and 132 kW at 440 V). Rated Operational Current AC-3 is 205 A for typical 415–440 V configurations, enabling reliable soft-start and switching for motors within these ranges.
The AF contactor family carries CE, UL/CSA (cULus) certifications, UKCA where applicable, and multiple global certificates (BV, RINA, ABS, LR, EAC, CB, CCC, and more) to support international deployments and compliance reporting.
Built-in surge protection reduces arcing wear, while modular auxiliary blocks simplify future upgrades without full rewiring. The compact design lowers panel space, and the 4P configuration supports higher motor loads with fewer devices. Over the device lifecycle, users typically see lower energy losses, reduced maintenance downtime, and easier spare-part management due to standardized ABB AF components.