ABB 1SFL537001R7000 Block Contactor - CE UL 690V 3P

Part Number: 1SFL537001R7000
Manufacturer
ABB
Part number
1SFL537001R7000

Quick Summary

ABB 1SFL537001R7000 Block Contactor is a high‑power switch for motor control in industrial panels. This three‑pole device delivers reliable switching for medium to heavy duty motors in demanding environments. Engineers often face space constraints, heat buildup, and reliability challenges; this contor is designed to minimize panel depth while delivering robust thermal current handling. It carries key certifications for global deployment, including CE and UL/CSA with CB and other third‑party approvals that reinforce compliance across regions. By combining compact footprint with versatile wiring and predictable performance, it supports faster commissioning and lower maintenance costs, delivering tangible value in automation and drive systems for pumps, conveyors, and compressors.

Product Information

Extended Description

1SFL537001R7000 ABB: AF260-30-00-70 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL547002R1300
Instructions and Manuals
N/A
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 260 A | (440 V) 55 °C 240 A | (500 V) 55 °C 240 A | (690 V) 55 °C 220 A | (380 / 400 V) 55 °C 260 A | (220 / 230 / 240 V) 55 °C 260
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 140 kW | (440 V) 140 kW | (500 V) 180 kW | (690 V) 200 kW | (380 / 400 V) 140 kW | (220 / 230 / 240 V) 80 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
300 cycles per hour | (AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
14 W | at Rated Operating Conditions per Pole 14 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69490
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.75 kg
Package Level 1 EAN
7320500381137
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3P, 690 V main circuit with high Ie ratings → Business Impact: Enables reliable, high‑power motor switching in tight panels → Application: Pumps, fans, compressors in industrial plants. Feature: Coil voltage range 100–250 V (50/60 Hz) and defined coil power (hold 10 V·A; pull‑in 470/520 W depending on voltage) → Business Impact: Flexible control options with predictable energization and reduced control energy, lowering running costs → Application: Centralized control from standard PLC/relay networks. Feature: Mechanical durability of 5 million cycles and a maximum switching frequency of 300 cycles per hour → Business Impact: Longer service life and lower maintenance intervals in high‑duty drives → Application: Material handling and packaging lines with frequent starts/stops. Feature: Connection capacity and terminal design (Main Circuit: bars up to 32 mm²; rigid cables 16–240 mm²; auxiliary wiring 2–4 mm²) plus 28 N·m tightening torque → Business Impact: Faster, error‑free wiring and reliable connections under vibration → Application: Panel wiring for large DC/AC drives and automation cabinets. Feature: Protection ratings (Coil IP20; Main IP00) and compact dimensions (approx. 140 mm W × 180.5 mm D × 227 mm H) → Business Impact: Safer installation in typical switchgear environments and easier enclosure planning → Application: OEM cabinets and retrofit projects requiring compact high‑power contactors. Feature: Certifications (CE, UL/CSA, CB, BV, DNV GL, RINA, ABS) and RoHS compliance → Business Impact: Global procurement confidence and regulatory readiness → Application: International manufacturing setups and multi‑site rollouts.

Get a Quick Quote for a ABB 1SFL537001R7000

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL537001R7000? Enquire Now

FAQs

Yes. The device supports main circuit connections using bars up to 32 mm², and it accommodates a range of cable sizes for main and auxiliary circuits (Rigid Al-Cable 120–240 mm²; Cu 16–240 mm²; Flexible 2×0.75–2.5 mm²). This simplifies panel wiring and improves reliability, even in vibration‑prone environments.
The rated AC-3 current varies by voltage. At 690 V and 55 °C, Ie is 220 A; at 440–500 V it is 240 A, and for 380/400 V it reaches about 260 A. This makes the 3P 1SFL537001R7000 suitable for high‑power motor control with robust switching performance.
The contactor carries CE and UL/CSA approvals, along with CB certification and additional third‑party attestations such as BV, DNV GL, RINA, and ABS. These certifications facilitate cross‑border procurement and help ensure regulatory compliance in diverse markets.
The coil supports 50 Hz or 60 Hz operation across 100–250 V, with holding and pull‑in power specified as 10 V·A (holding at rated voltage for 50/60 Hz) and 470–520 W (pull‑in at rated voltage for 50/60 Hz/DC). This enables flexible integration with different control circuits while optimizing energy use.
The block contactor offers up to 5 million mechanical operations and up to 300 switching cycles per hour, reducing replacement frequency in busy drives. Its durable design, combined with robust insulation and protective ratings, supports long‑term reliability in conveyors, pumps, and compressors with limited downtime.