ABB 1SFL537001R7011 Block Contactor - CE UL CSA
Part Number: 1SFL537001R7011
Quick Summary
Block Contactor ABB 1SFL537001R7011 provides reliable motor control for three-phase drives in industrial automation. Varying control voltages and mounting constraints can complicate installation and uptime, making a flexible, robust solution essential. It carries CE and UL/CSA listings, plus RINA certification for broader global deployment, reinforcing compliance across diverse markets. Designed for high-current motor starting and distribution, this ABB contactor delivers consistent switching performance, compact footprint, and straightforward integration into control cabinets and switchgear—supporting efficiency, safety, and project uptime across your electrical protection and circuit control needs.
Product Information
Extended Description
1SFL537001R7011 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL547002R1311
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.1 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 260 A | (440 V) 55 °C 240 A | (500 V) 55 °C 240 A | (690 V) 55 °C 220 A | (380 / 400 V) 55 °C 260 A | (220 / 230 / 240 V) 55 °C 260
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 140 kW | (440 V) 140 kW | (500 V) 180 kW | (690 V) 200 kW | (380 / 400 V) 140 kW | (220 / 230 / 240 V) 80 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
300 cycles per hour | (AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
14 W | at Rated Operating Conditions per Pole 14 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69490
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115199
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
7320500217641
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3709248
E-Number (Norway)
4115279
E-Number (Sweden)
3228316
Feature 1: 3P main contacts with 1 NO auxiliary and 1 NC auxiliary contact enable reliable control logic and feedback in motor start/stop sequences → Business Impact: Simplifies interlocking schemes and reduces wiring complexity, lowering installation time and potential wiring errors → Application: Motor control centers and automation panels requiring integrated feedback and interlock functionality. Feature 2: Control circuit voltage range 100 … 250 V AC or DC operation → Business Impact: Flexible integration with existing control systems and spare parts, reducing inventory costs and wiring changes → Application: Industrial PLCs and control relays with varied coil supply. Feature 3: Rated main circuit voltage up to 690 V and rated current up to 400 A (AC-1) with AC-3 performance at multiple voltages → Business Impact: Supports heavy motor loads and distribution tasks with proven endurance, improving equipment uptime and reducing fuse/replacement events → Application: Heavy-duty motor starting and distribution in manufacturing lines. Feature 4: Short-circuit protection compatibility with gG fuses up to 500 A → Business Impact: Enhanced protection against short circuits, enabling safer panel designs and easier protection coordination → Application: Panels requiring compliant protection devices in line with IEC 60947 standards. Feature 5: Insulation and protection ratings including U i 1000 V and main terminals IP00, coil terminals IP20 → Business Impact: Safer operation and easier compliance with insulation and protection requirements in harsh factory environments → Application: Indoor switchgear and cabinet installations with rigorous IP considerations. Feature 6: Robust mechanical durability and defined operating metrics (Ith 400 A, controller coil consumption, and precise operate times) → Business Impact: Predictable lifecycle and maintenance planning, reducing unexpected downtime → Application: High-uptime automation lines and serviceable equipment in OEM systems. Feature 7: Bar-style main connections and 32 mm² connecting capacity → Business Impact: Fast, secure wiring with reliable torque performance, simplifying field installation and service → Application: Panel builders and electrical contractors assembling heavy conductors. Feature 8: Comprehensive certifications including CE, UL/CSA and RINA support global deployments with marine/industrial applicability → Business Impact: Streamlined procurement for multinational projects and multi-site compliance → Application: Global manufacturing facilities with cross-border equipment approvals.
Get a Quick Quote for a ABB 1SFL537001R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL537001R7011?
Enquire Now
FAQs
The coil supports 100-250 V for AC, 100-250 V for AC/DC operation, enabling flexible interfacing with diverse control systems and minimizing the need for adapters or supplementary power supplies.
Yes. The device is specified for main circuit voltages up to 690 V and provides AC-3 performance ratings across multiple voltages, making it suitable for motor starting and heavy-duty switching in 3-phase systems.
The product carries CE and UL/CSA listings, with additional RINA certification, supporting compliance in European and international markets and suitable for marine or heavy-duty environments.
Main circuit connections use bars with 32 mm² capacity, while auxiliary circuits support flexible or solid conductors in the 0.75–4 mm² range. This enables secure, versatile wiring in control cabinets.
It supports compatible gG-type fuses for short-circuit protection and offers predictable mechanical/electrical life (up to 5 million operating cycles). Regular inspections of connections and coil health help maintain performance and reliability.