ABB 1SFL537001R7022 Contactor - Up to 690V, AC/DC 100-250V
Part Number: 1SFL537001R7022
Quick Summary
ABB 1SFL537001R7022 Contactor is a versatile 3-phase switch designed for motor starting and power distribution in demanding industrial environments. It addresses common control challenges by supporting a wide control voltage range from 100 to 250 V AC or DC, reducing wiring complexity and inventory needs. This device aligns with industry standards such as CE compliance and IEC-based expectations, ensuring safe operation in machine rooms and field installations. By selecting this ABB contactor, engineers gain reliable performance, simplified maintenance, and lower total cost of ownership through fewer variant SKUs and faster commissioning. For growing plants embracing automation, it also integrates smoothly with ABB drives and protection ecosystems to streamline control architectures and preserve uptime.
Product Information
Extended Description
1SFL537001R7022 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, AC/DC
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Lead Time
23 day
Country of Origin
Sweden (SE)
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
23 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Sweden (SE)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL547002R1322
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.1 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 260 A | (440 V) 55 °C 240 A | (500 V) 55 °C 240 A | (690 V) 55 °C 220 A | (380 / 400 V) 55 °C 260 A | (220 / 230 / 240 V) 55 °C 260
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 140 kW | (440 V) 140 kW | (500 V) 180 kW | (690 V) 200 kW | (380 / 400 V) 140 kW | (220 / 230 / 240 V) 80 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 14 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69490
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115199
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
7320500222812
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Wide control voltage range of 100-250 V AC/DC. Business Impact: Reduces wiring complexity and part variants, enabling flexible control across multiple equipment types. Application: conveyors, pumps and fans in process lines. Feature: Three-phase design with a maximum of 690 V. Business Impact: Supports high-voltage motor circuits, improving reliability in heavy-duty drives and minimizing the need for additional protective components. Application: plant-wide motor control in packaging and manufacturing. Feature: Suitable for motor starting, isolation, bypass and distribution. Business Impact: Unifies control tasks in a single device, lowering capital costs and simplifying maintenance. Application: isolation and bypass configurations in packaging lines and processing equipment. Feature: Clear lead times and stocked availability. Business Impact: Predictable procurement supports project scheduling and reduces downtime during upgrades. Application: new line commissioning and retrofits. Feature: Compatibility with ABB protection and drive ecosystems. Business Impact: Streamlines wiring, reduces spare parts, and accelerates commissioning through standardized interfaces. Application: integrated automation architectures across the plant.
Get a Quick Quote for a ABB 1SFL537001R7022
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL537001R7022?
Enquire Now
FAQs
Yes. The 1SFL537001R7022 is designed for three-phase motor control and supports a broad control voltage range of 100-250V AC/DC, enabling integration with common plant control circuits. Compatibility with standard ABB electrical interfaces reduces wiring changes and minimizes commissioning time during retrofits or new installs.
The contactor provides a control voltage range of 100-250V AC/DC and a maximum system voltage rating of 690V. This combination supports motor starting and distribution for a wide range of industrial drives while maintaining safe and reliable switching performance.
Absolutely. The 3-phase design with 690V max and 100-250V control voltage is well suited for motor starting, isolation, bypass, and distribution in conveyors and packaging lines. Its robust ABB construction enhances uptime and simplifies maintenance in continuous-process environments.
While specific certifications should be confirmed on the datasheet for each region, ABB contactors in this class typically align with IEC-based standards and CE-related requirements for industrial automation. For critical safety or equipment integration, verify exact certification marks and testing details with the supplier or distributor before deployment.
Choosing the 1SFL537001R7022 consolidates control needs into a single, robust solution, reducing SKU proliferation and spare parts. This simplifies stocking, lowers maintenance complexity, shortens downtime during swaps, and accelerates commissioning, delivering a lower total cost of ownership over the asset lifecycle.