ABB 1SFL537001R7222 Block Contactor - CE Certified
Part Number: 1SFL537001R7222
Quick Summary
ABB 1SFL537001R7222 Block Contactor is designed for motor starting and distribution in 690 V systems. The DC coil operates across a wide 20–60 V control range, enabling flexible integration with varied control circuits. Engineers often struggle with limited coil options and reliability under fluctuating temperatures; this device delivers consistent switching performance and robust operation in demanding environments. It carries CE conformity and UL/CSA approvals, alongside other global certifications, reinforcing safety and regulatory compliance across regions. By combining a compact footprint with strong load ratings, it supports faster panel assembly and reduced wiring complexity, delivering uptime and lower total cost of ownership for conveyor, pump, and HVAC motor-control applications.
Product Information
Extended Description
1SFL537001R7222 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 20-60 V, DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL547002R1122
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.1 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 260 A | (440 V) 55 °C 240 A | (500 V) 55 °C 240 A | (690 V) 55 °C 220 A | (380 / 400 V) 55 °C 260 A | (220 / 230 / 240 V) 55 °C 260
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 140 kW | (440 V) 140 kW | (500 V) 180 kW | (690 V) 200 kW | (380 / 400 V) 140 kW | (220 / 230 / 240 V) 80 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 14 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69490
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115199
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
7320500222829
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3P Block Contactor uses a 690 V main circuit and a 20–60 V DC coil, enabling reliable motor starting across a wide control voltage landscape; this reduces the need for additional relays and simplifies spare parts management in industrial automation setups. Benefit: Faster installation and fewer components lower panel space and installation time, particularly in control cabinets for fans and conveyors. Application: Suitable for diverse load profiles in manufacturing lines where space is at a premium and quick, repeatable switching is essential. Feature → Business Impact → Application: Rated Operational Current AC-3 up to 260 A at 415–690 V and DC-3 up to 400 A demonstrates high motor-load handling with protective margins; Benefit: Improved motor-start reliability and reduced fuse or breaker trips in high-load scenarios. Application: Heavy-duty pump and compressor drives in process industries. Feature → Business Impact → Application: Mechanical durability rated at 5 million cycles and standard dimensions (W 140 mm, D 180.5 mm, H 227 mm) provide predictable lifecycle costs and easier enclosure planning; Application: OEMs designing compact motor control panels for packaging lines or HVAC applications. Feature → Business Impact → Application: Precise connection capabilities—main circuit bar 32 mm² and auxiliary circuit flex cables 0.75–2.5 mm²—support flexible wiring schemes; Benefit: Simplified field wiring, quicker commissioning, and robust terminations. Application: Modern control rooms and retrofit projects where wiring versatility matters. Feature → Business Impact → Application: IP20 coil terminals and IP00 main terminals offer dependable protection alignment with standard electrical enclosures; Benefit: Safer installation and improved maintenance access in factory floors. Application: New builds and upgrades in automation lines requiring compliant, scalable motor control.
Get a Quick Quote for a ABB 1SFL537001R7222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL537001R7222?
Enquire Now
FAQs
This 3P block contactor offers product net dimensions of 140 mm width, 180.5 mm depth, and 227 mm height with a net weight of 5.1 kg, designed for main circuit connections via 32 mm² bars and rigid copper/aluminum cables up to 240 mm². Auxiliary connections accommodate 0.75–2.5 mm² flexible or 2–4 mm² solid cables. The unit is IP20 on coil terminals and IP00 on main terminals, facilitating straightforward panel integration and standard enclosure compatibility.
The coil operates from 20 to 60 V DC, offering flexible control options for varying control circuits without additional relays. Coil consumption includes holding and pull-in values suitable for steady-state control and dynamic switching, helping to minimize energy use and thermal load in start/stop sequences while supporting reliable actuation in temperature-varied environments.
Rated Operational Current AC-3 is up to 260 A at 415–690 V and up to 240 A at some higher voltage combinations, with DC-3 ratings around 400 A for 110–220 V configurations. This makes the contactor suitable for demanding motor-starting tasks and distribution schemes in conveyors, pumps, and fans, offering robust performance with a clear safety margin.
Yes. The device carries CE conformity and UL/CSA approvals, with additional certificates listed for global compliance (BV, GL, RINA, etc.). These certifications support safe operation in regulated environments and facilitate acceptance in international projects, ensuring that panel builds meet essential electrical and safety requirements.
With a mechanical durability of 5 million cycles and high breaking/making capacities, the contactor offers long service intervals and reduced replacement frequency. The wide coil voltage tolerance simplifies stocking and diagnostics, while compact dimensions and compatible wiring enable faster commissioning and lower total cost of ownership for automation upgrades in manufacturing lines.