ABB 1SFL537063R6911 Block Contactor - IEC/EN 60947-4-1
Part Number: 1SFL537063R6911
Quick Summary
ABB 1SFL537063R6911 is a railway-grade block contactor that reliably switches three-phase motors in rolling stock and traction drives. Engineers often contend with narrow control range compatibility and challenging panel layouts that slow commissioning. It meets IEC/EN 60947-4-1, UL 60947-4-1, and EN 50155 requirements, giving rail and industrial users confidence in safety and uptime. With a wide coil range of 48–130 V and a 690 V main circuit, it reduces spare parts and simplifies procurement. This combination also supports cross-market deployment in manufacturing automation and supply-chain equipment, enhancing maintenance planning and reducing downtime.
Product Information
Extended Description
1SFL537063R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL547063R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.5 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 260 A | (440 V) 55 °C 240 A | (500 V) 55 °C 240 A | (690 V) 55 °C 220 A | (380 / 400 V) 55 °C 260 A | (220 / 230 / 240 V) 55 °C 260
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 140 kW | (440 V) 140 kW | (500 V) 180 kW | (690 V) 200 kW | (380 / 400 V) 140 kW | (220 / 230 / 240 V) 80 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 14 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69490
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115199
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
6.2 kg
Package Level 1 EAN
7320500258446
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Three-pole main NO contacts with one NO/1 NC auxiliary contact provides precise motor control and interlocking, reducing the need for additional relays and simplifying panel wiring; ideal for railway traction drives and conveyors. Feature → Business Impact → Application: Coil operating range 48–130 V AC/DC enables universal compatibility across regional power standards, lowering stocking costs and speeding installation in mixed fleets. Feature → Business Impact → Application: Main circuit rated up to 690 V with 50/60 Hz operation supports high-power switching for large conveyor systems and rail propulsion, reducing device counts and maintenance intervals. Feature → Business Impact → Application: Insulation Voltage Ui of 1000 V and IP20 coil terminals with IP00 main terminals improve safety and ease of installation in confined enclosures. Feature → Business Impact → Application: Mechanical durability of 5 million cycles and a maximum switching frequency of 300 cycles per hour deliver long service life in high-cycle rail applications, lowering total cost of ownership. Feature → Business Impact → Application: Robust wiring and connection options—32 mm² terminal capacity for main circuit and flexible/solid options for auxiliary circuit—facilitate quick, secure installations in new builds or retrofits.
Get a Quick Quote for a ABB 1SFL537063R6911
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL537063R6911?
Enquire Now
FAQs
The device uses flat main-terminals designed for 32 mm² bars and requires a tightening torque of 28 N·m on the main circuit connections. When wiring the auxiliary circuit, use flexible with ferrule 1x 0.75–2.5 mm² or solid 2 x 1–4 mm² conductors. Plan for IP20 rated coil terminals and provide appropriate clearances to avoid overheating. Proper mounting reduces heat buildup and ensures reliable operation in rail and industrial panels.
For AC-1 at 690 V, the device provides up to 400 A at 40 °C, 350 A at 55 °C, and 290 A at 70 °C. For AC-3, ratings vary by voltage: at 415 V 55 °C the device can switch about 260 A, at 440 V 55 °C about 240 A, and at 690 V 55 °C about 220 A. These figures support heavy motor starting and acceleration profiles typical in rail drives.
Yes. It carries certification references aligned with rail and heavy-duty use, including IEC/EN 60947-4-1, EN 50155 applicability, IEC 61373, and TR CU 001/2011, with shock resistance and wide operating temperature ranges. The product also supports operation up to -40 to 70 °C in non-thermal-relay configurations and up to 3000 m altitude without derating, making it well-suited for rolling stock and track-side installations.
The contactor is CE and UL/CSA listed with DoC documentation, along with BV, GL, LR, RINA, RMRS, and EAC certificates. It includes CCC and CE conformity declarations and RoHS compliance. This broad certification portfolio supports compliance in global rail and industrial supply chains and helps streamline regulatory approvals during procurement.
With 5 million mechanical operating cycles and a maximum switching rate of 300 cycles per hour, the device delivers long service life in high-cycle applications such as railway traction and conveyor systems. Its robust insulation (Ui 1000 V) and durable construction reduce replacement frequency, while the integrated auxiliary contact set supports diagnostic signaling, contributing to lower maintenance costs and improved uptime.