ABB AF265-30-11-31 Contactor - AF Technology, 1000V IEC/UL
Part Number: 1SFL547002R3111
Quick Summary
ABB AF265-30-11-31 Contactor is a three-pole motor controller designed for demanding industrial drives. In practice, engineers face control voltage variation and energy waste in panels, which can compromise reliability; AF technology tolerates wide control voltage ranges (24–60 V AC or 20–60 V DC) and includes built‑in surge protection to reduce misoperations. This device aligns with CE conformity and UL/CSA compatibility, and offers coil-terminal IP20 protection with main-terminals IP00. For OEMs and panel builders, the compact block design plus easy accessory expansion translates to lower installation time and scalable protection for growing motor-control needs, particularly in automated production lines and material handling systems.
Product Information
Extended Description
1SFL547002R3111 ABB: The AF265-30-11-31 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) or 200 hp / 480 V UL and switching power circuits up to 400 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
191 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 265 A | (440 V) 60 °C 265 A | (500 V) 60 °C 250 A | (690 V) 60 °C 250 A | (1000 V) 60 °C 113 A | (380 / 400 V) 60 °C 265 A | (220 / 230 / 240 V) 60 °C 265 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (440 V) 160 kW | (500 V) 160 kW | (690 V) 200 kW | (1000 V) 160 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24...60 V | DC Operation 20...60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 9 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 9 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Holding at Max. Rated Control Circuit Voltage DC 3.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 32 W | at Rated Operating Conditions AC-3 per Pole 14 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Continuous Current Rating NEMA
270 A
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 221 A | (220 ... 240 V AC) Three Phase 248 A | (440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561782
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature AF technology provides a wide control voltage range and built-in surge protection → This reduces voltage-related misoperations and energy waste in panels, enhancing motor start reliability and energy efficiency in dynamic networks. Application: suitable for three-pole motor control up to 132 kW at 380–400 V and up to 200 kW at higher voltages, with AC-3 operation. Feature Compact block design with 3 main contacts and 1 NO/1 NC auxiliary contact → Enables space-saving installations and easy expansion with auxiliary contact blocks for personalized control schemes. Application: ideal for motor protection and control in conveyors, pumps, and presses. Feature Main circuit bars for connections and IP ratings → Improves reliability in industrial environments and simplifies wiring with clear, robust connections. Application: straightforward integration into panel layouts and existing ABB ecosystems. Feature Coil range 24–60 V AC, 20–60 V DC with low coil consumption → Lowers energy use in standby and reduces heat within control cabinets. Application: supports energy-efficient control circuits and compatibility with standard PLC outputs. Feature High-rated operational currents and power handling → Supports demanding loads with rated AC-1 up to 400 A and AC-3 up to 265 A at common voltages, enabling broader motor starts without overdesign. Application: helps prevent nuisance trips and extends motor life in heavy-duty applications. Feature Expanded documentation and accessories ecosystem → Reduces design risk and speeds engineering cycles. Application: easy CAD integration, available manuals, and add-on accessory compatibility for scalable deployments.
Get a Quick Quote for a ABB 1SFL547002R3111
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL547002R3111?
Enquire Now
FAQs
Yes. The AF265-30-11-31 coil is designed for a broad control voltage range: 24–60 V AC at 50/60 Hz and 20–60 V DC. This tolerance enables stable operation in panels with fluctuating control voltages, minimizing misstarts and reducing panel heat. When wiring, ensure the control circuit terminals are connected to a protected, correctly rated drive signal to maximize reliability.
At 1000 V, the contactor provides a rated operational current AC-3 of up to 113 A (60 °C) and a power rating around 160 kW, with alternative ratings at different voltages (e.g., 132 kW at 415 V). At 690 V, AC-3 current is around 250–265 A depending on ambient temperature, with corresponding power ratings up to 200 kW. These figures guide safe motor sizing and protection coordination.
The AF265-30-11-31 carries CE conformity and UL/CSA compatibility, with RoHS and REACH declarations in place. It features protective insulation up to 1000 V for main circuits, IP20 coil terminals, and IPC-compliant design for reliable operation in industrial environments. For end-of-life handling, ABB provides disassembly instructions and environmental declarations to support compliance programs.
The device uses main circuit bars with dimensions of approximately 140 mm wide, 191 mm deep, and 225 mm high, weighing about 3.9 kg. It supports a block-contact design with 3 main contacts and 1 NO/1 NC auxiliary contact. Ensure proper mounting in panels with adequate clearance, connect main circuits with torque-appropriate lugs, and account for IP20 coil terminals and IP00 main terminals in enclosure sealing and protection planning.
With an industrial mechanical durability of about 5 million cycles and optimized coil consumption (holding and pull-in values across frequencies), the AF265-30-11-31 delivers reduced energy use and fewer nuisance trips. Its AF technology supports wider voltage tolerance, minimizing panel reconfigurations after supply disturbances. Long-term maintenance benefits include fewer spare parts for coil drive issues and straightforward accessory expansion for scalability.