ABB 1SFL547002R3200 Contactor - 1000 V AF Tech

Part Number: 1SFL547002R3200
Manufacturer
ABB
Part number
1SFL547002R3200

Quick Summary

ABB 1SFL547002R3200 Contactor enables motor control for industrial drive systems. In today’s plants, voltage swings and panel-space constraints erode uptime and drive energy use. This AF technology offers a wide control voltage range and built-in surge protection to maintain reliable operation in unstable networks while reducing energy waste. It carries CE and UL/CSA certifications, and protection ratings such as IP20 for coil terminals and IP00 for main terminals, with UKCA in eligible markets, supporting global compliance. The AF design supports modular expansion with add-on auxiliary contact blocks and a full accessories suite, delivering scalable control for future capacity needs and simplified maintenance, ultimately lowering total cost of ownership.

Product Information

Extended Description

1SFL547002R3200 ABB: The AF265-30-00-32 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) or 200 hp / 480 V UL and switching power circuits up to 400 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
191 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 265 A | (440 V) 60 °C 265 A | (500 V) 60 °C 250 A | (690 V) 60 °C 250 A | (1000 V) 60 °C 113 A | (380 / 400 V) 60 °C 265 A | (220 / 230 / 240 V) 60 °C 265 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (440 V) 160 kW | (500 V) 160 kW | (690 V) 200 kW | (1000 V) 160 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 360 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 32 W | at Rated Operating Conditions AC-3 per Pole 14 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Continuous Current Rating NEMA
270 A
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 221 A | (220 ... 240 V AC) Three Phase 248 A | (440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561805
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: AF technology provides a wide control voltage range (48–130 V AC/DC), reducing panel wiring complexity and energy waste while enabling stable operation across fluctuating networks. This translates to lower energy usage and improved uptime in continuous-process lines, conveyors, and pumps. Feature → Business Impact → Application: Three-pole, 1000 V main circuit capability with AC-3 ratings up to 265 A (at 415 V) and 113 A (at 1000 V) supports high‑power motor starts, reducing starter failures and enabling smoother commissioning in packaging, plastics, and material handling. Feature → Business Impact → Application: Built‑in surge protection in a compact block design lowers external protection needs and simplifies installation while enabling quick field upgrades with add-on auxiliary contact blocks for automation scalability. Feature → Business Impact → Application: Coil power characteristics (hold and pull-in values across 50/60 Hz and DC operation) deliver energy efficiency during hold and reliable actuation during start, contributing to lower total cost of ownership in automated lines. Feature → Business Impact → Application: Durability ratings (up to 5 million mechanical cycles) and IP protection ratings offer long service life in harsh environments, reducing maintenance downtime in heavy machinery, pumps, and hoists. Certification and compliance coverage (CE, UL/CSA, UKCA) simplifies procurement and regulatory adherence, supporting global deployments across multiple facilities while reducing compliance risk.

Get a Quick Quote for a ABB 1SFL547002R3200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL547002R3200? Enquire Now

FAQs

Preparation starts with de-energizing the system and verifying compatibility for 3P mains. Mount the unit so main circuit bars align with the busbar interfaces, then secure the connectors per the recommended torque. Use 22–43 N·m for main circuit connections and ensure proper alignment of the coil terminals. Wire the control circuit to 48–130 V (AC or DC) and install any add-on auxiliary contact blocks as needed to match your control logic. Finally, perform a functional test to confirm proper switching and interlock behavior before commissioning.
For AC-3 operation, the device provides 265 A at 415 V, 250 A at 690 V, and down to 113 A at 1000 V (all at 60 °C). These values reflect the device’s capability to start and run common industrial motors with substantial starting torque while maintaining safe thermal margins. Always select a rating that includes your worst‑case operating voltage and ambient temperature to ensure reliable performance.
Yes. With three main contacts and 3P configuration, plus a main circuit voltage rating up to 1000 V and AC-3 power ratings up to 160 kW (depending on voltage), it is well suited for motor control in conveyors, pumps, and similar drive applications. The wide control voltage range (48–130 V) and built‑in surge protection simplify integration with existing control systems and improve resilience in fluctuating electrical networks.
The device carries CE and UL/CSA certifications and supports UKCA where applicable, along with RoHS/REACH compliance and WEEE considerations. It also features IP ratings for coil terminals (IP20) and main terminals (IP00). These certifications ensure regulatory compliance across regions, enable safer operation in industrial environments, and streamline global procurement and installation with reduced risk.
AF technology delivers energy efficiency through reduced control voltage variation and optimized coil consumption, contributing to lower operating costs. The contractor’s durability—up to 5 million mechanical cycles—and integrated surge protection reduce maintenance frequency and spare parts, delivering faster ROI in automation projects and long‑term lifecycle savings across production lines.