ABB AF265B-30-22-11 Contactor - 1000V, CE/UL IEC

Part Number: 1SFL547063R1122
Manufacturer
ABB
Part number
1SFL547063R1122

Quick Summary

ABB AF265B-30-22-11 Contactor is a 3-pole motor starter for industrial machines. In panel assemblies, voltage variations can trigger nuisance trips and waste energy, but AF technology helps stabilize coil control. It carries CE and UL/CSA approvals, plus RoHS and REACH declarations to support global deployment, reducing compliance risk. The compact design with built-in surge protection enables denser panel layouts and longer equipment life. For buyers, this means lower installation, maintenance costs, and improved motor protection in electrical protection and circuit control applications. The device also supports easy expansion with add-on auxiliary contact blocks to future-proof control schemes.

Product Information

Extended Description

1SFL547063R1122 ABB: The AF265B-30-22-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 132 kW / 400 V AC (AC-3) or 200 hp / 480 V UL and switching power circuits up to 400 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF265, AF305,AF370
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A | (440 V) 55 °C 265 A | (500 V) 55 °C 250 A | (690 V) 55 °C 250 A | (1000 V) 55 °C 100 A | (380 / 400 V) 55 °C 265 A | (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 400 A | (100 V) 1 Pole, 60 °C 350 A | (100 V) 1 Pole, 70 °C 290 A | (110 V) 1-Pole, 40 °C 400 A | (110 V) 1-Pole, 60 °C 350 A | (110 V) 1-Pole, 70 °C 290 A | (110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (175 V) 2 Poles in Series, 40 °C 400 A | (175 V) 2 Poles in Series, 60 °C 350 A | (175 V) 2 Poles in Series, 70 °C 290 A | (200 V) 2 Poles in Series, 40 °C 400 A | (200 V) 2 Poles in Series, 60 °C 350 A | (200 V) 2 Poles in Series, 70 °C 290 A | (220 V) 2 Poles in Series, 40 °C 400 A | (220 V) 2 Poles in Series, 60 °C 350 A | (220 V) 2 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (260 V) 3 Poles in Series, 40 °C 400 A | (260 V) 3 Poles in Series, 60 °C 350 A | (260 V) 3 Poles in Series, 70 °C 290 A | (300 V) 3 Poles in Series, 40 °C 400 A | (300 V) 3 Poles in Series, 60 °C 350 A | (300 V) 3 Poles in Series, 70 °C 290 A | (340 V) 3 Poles in Series, 40 °C 400 A | (340 V) 3 Poles in Series, 60 °C 350 A | (340 V) 3 Poles in Series, 70 °C 290 A | (72 V) 1-Pole, 40 °C 400 A | (72 V) 1-Pole, 60 °C 350 A | (72 V) 1-Pole, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A | (90 V) 1 Pole, 40 °C 400 A | (90 V) 1 Pole, 60 °C 350 A | (90 V) 1 Pole, 70 °C 290 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 200 kW | (1000 V) 160 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
14 W | at Rated Operating Conditions per Pole 14 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Continuous Current Rating NEMA
270 A
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 221 A | (220 ... 240 V AC) Three Phase 248 A | (440 ... 480 V AC) Three Phase 240 A | (550 ... 600 V AC) Three Phase 242 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SE-89316
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500511145
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210448
Feature AF265B-30-22-11 uses a 3-pole block contactor design with pre-mounted auxiliary contacts and a 1000 V main circuit. Business Impact This enables high-power motor switching with a compact footprint, reducing panel size and wiring complexity while improving reliability in automation lines. Application Suitable for industrial drives such as conveyors, pumps, and machine tools where space is at a premium and uptime is critical. Feature Wide coil voltage range 24-60 V AC / 20-60 V DC supports diverse control networks. Business Impact Simplifies control schemes and tolerates voltage variations without nuisance trips, lowering maintenance costs. Application Ideal for multi-network automation panels and retrofit projects where control voltage flexibility matters. Feature Built-in surge protection and extendable with add-on auxiliary blocks. Business Impact Reduces components, accelerates commissioning, and lowers total cost of ownership. Application Helps in scalable control circuits across evolving machine architectures. Feature 3 main contacts and 2 NO/2 NC auxiliary contacts. Business Impact Enables comprehensive motor protection and convenient interlocking within a compact device. Application Useful in electrical protection & circuit control for multi-motor systems. Feature Mechanical durability rated at 5 million cycles with a maximum switching frequency of 300 cycles per hour. Business Impact Delivers long service life in high-demand production lines, reducing replacement cycles. Application Suitable for frequent start/stop applications in process and packaging lines. Feature NEMA Size 5, continuous current rating of 270 A, and HP ratings across voltage families. Business Impact Ensures compatibility with standard industrial motor loads and predictable thermal performance. Application Appropriate for 200–250 kW scale drives and similar mid-range applications where reliability matters. Feature Main Circuit Bars for terminal connections and specific dimensions: 140 mm width, 180 mm depth, 225 mm height; net weight 3.9 kg. Business Impact Facilitates straightforward installation and integration into standard control panels with predictable space needs. Application Ideal for retrofits and new builds in electrical protection and circuit control setups.

Get a Quick Quote for a ABB 1SFL547063R1122

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL547063R1122? Enquire Now

FAQs

The AF265B-30-22-11 Contactor supports a wide control voltage range of 24-60 V AC (50/60 Hz) and 20-60 V DC, enabling flexible integration with diverse control networks and improving reliability in networks with voltage fluctuations.
The device features a 1000 V main circuit rating, 3 main contacts, and 2 NO/2 NC auxiliary contacts. It provides AC-3 ratings up to 265 A at higher voltages (typical for 415–690 V ranges) and AC-1 ratings up to 350 A at 1000 V, suitable for residential-to-industrial motor loads.
Net dimensions are 140 mm in width, 180 mm in depth, and 225 mm in height, with a net weight of 3.9 kg. This compact footprint facilitates dense panel layouts and straightforward mounting using standard terminal bars.
The AF265B-30-22-11 carries CE and UL/CSA approvals, RoHS and REACH declarations, ensuring global compliance for panel builders and integrators across multiple regions.
Yes. The AF265B-30-22-11 features a block-type design that is easily extended with add-on auxiliary contact blocks, enabling scalable control configurations without replacing the base device.