ABB 1SFL547074R8511 Contactor - UL Listed

Part Number: 1SFL547074R8511
Manufacturer
ABB
Part number
1SFL547074R8511

Quick Summary

The ABB 1SFL547074R8511 Contactor is a high-capacity three-phase motor starter designed for reliable control in industrial panels. Engineers often confront crowded plant cabinets, complex wiring, and heat buildup when upgrading motor control, and this unit helps address those challenges with a compact footprint and integrated auxiliary contacts. It carries CE and UL certifications, plus RoHS and REACH compliance, supporting global sourcing and supplier qualification. With a net width of 140 mm and a weight of 4.7 kg, the device streamlines installation while delivering robust protection and long service life for panel builders and OEMs seeking dependable power switching and reduced maintenance costs.

Product Information

Extended Description

1SFL547074R8511 ABB: AX260-30-11-85 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
1SFC101062M0201_E
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
4.7 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 400 A | (690 V) 55 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A | (440 V) 55 °C 265 A | (500 V) 55 °C 250 A | (690 V) 55 °C 250 A | (380 / 400 V) 55 °C 265 A | (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (440 V) 160 kW | (500 V) 160 kW | (690 V) 200 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Power Loss
at Rated Operating Conditions per Pole 14 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
175 mm
Package Level 1 Depth / Length
270 mm
Package Level 1 Height
223 mm
Package Level 1 Gross Weight
5.4 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The block contactor design provides 3 main normally open contacts (NO) plus 1 NO and 1 NC auxiliary contact, enabling straightforward control circuits and reduced wiring complexity in conveyors and pumps. This translates to faster panel assembly, easier diagnostics, and improved startup sequencing for 3P motor systems. Application: suitable for heavy-duty industrial motors in manufacturing lines. Feature → Business Impact → Application: Rated insulation voltage up to 690 V and rated operational currents for AC-3 operation across multiple voltages (e.g., 415 V, 440 V, 500 V, 690 V) ensure safe, compliant switching of high-voltage motors with predictable performance. This supports equipment like fans, pumps, and presses in process industries. Feature → Business Impact → Application: Heat loss of 14 W per pole and a mechanical durability of 5 million cycles deliver energy efficiency and longevity, reducing maintenance milestones and downtime. Application: ideal for high-cycle applications in material handling and packaging lines. Feature → Business Impact → Application: The main circuit uses bars for terminals, simplifying field wiring and busbar integration; compact dimensions (140 mm W × 180 mm D × 225 mm H) and 4.7 kg weight enable tighter panel layouts and easier relocation during line redesigns. Application: control panels with space constraints and frequent reconfiguration. Feature → Business Impact → Application: Broad certifications (CE, UL, CCC, CQC) plus RoHS/REACH/TCSA compliance mitigate regulatory risk and support global supply chains. Application: OEMs targeting multinational deployments and safety-compliance programs. Feature → Business Impact → Application: CAD dimensional drawings and data sheets available streamline engineering prep, reduce design cycle times, and accelerate spare-part planning. Application: system integrators requiring quick access to documentation for installation and maintenance.

Get a Quick Quote for a ABB 1SFL547074R8511

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL547074R8511? Enquire Now

FAQs

Begin by verifying the main circuit terminals are designed for bar connections and ensure the panel busbars are rated for the expected current. Mount the contactor securely, connect the three main NO contacts to the motor supply, and wire the auxiliary contact in accordance with the control circuit voltage (380-400 V at 50 Hz or 400-415 V at 60 Hz). Use proper torque on all terminals and observe the ambient temperature limits to maintain performance.
For AC-3 operation at 55 °C, the contactor provides rated currents of up to 265 A at common voltages such as 415 V, 440 V, 500 V, and 690 V, with corresponding 132–200 kW rated loads depending on voltage. The device supports 60 Hz mains and has a rated insulation voltage of 690 V, suitable for high-demand motor control applications.
Yes. The product specifications indicate a maximum operating altitude of 3000 meters without derating, making it suitable for mountainous or high-altitude facilities. Maintain proper ventilation to manage thermal load, and verify that ambient temperatures fall within the -25 to 70 °C range depending on proximity to auxiliary relays.
The device includes one auxiliary normally open (NO) contact and one auxiliary normally closed (NC) contact in addition to the three main NO contacts. This arrangement supports control circuit feedback, interlock circuits, and motor overload control without needing additional relays, reducing panel space and wiring complexity.
The contactor carries UL/cUL listings and CE declarations, along with RoHS and REACH compliance. It also aligns with CMRT, TSCA, and WEEE B2B guidelines, ensuring regulatory compatibility for global sourcing, environmental responsibility, and safe material usage in assemblies.