ABB AF265-40-11-14 Contactor - CE & UL Listed

Part Number: 1SFL547102R1411
Manufacturer
ABB
Part number
1SFL547102R1411

Quick Summary

AF265-40-11-14 Contactor is a four-pole device engineered to reliably switch motors and power circuits up to 132 kW at 400 V AC (AC-3). This helps control panels stay compact while maximizing uptime in demanding environments. Many facilities struggle with voltage fluctuations and erratic control signals that cause nuisance trips and energy waste. The AF265 family mitigates this with AF technology and a wide control voltage range of 250–500 V AC, plus DC operation, stabilizing performance in unstable networks. With CE and UL/CSA, UKCA, and other major certifications, this contactor supports global compliance. Its compatibility with add-on auxiliary blocks and accessories delivers scalable, end-to-end motor protection and control for modern automation lines, reducing wiring complexity and total cost of ownership.

Product Information

Extended Description

1SFL547102R1411 ABB: The AF265-40-11-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) / and switching power circuits up to 400 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF265,AF305,AF370
Product Net Width
184.4 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A | (440 V) 55 °C 265 A | (500 V) 55 °C 250 A | (690 V) 55 °C 250 A | (380 / 400 V) 55 °C 265 A | (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (440 V) 160 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage DC 4.7 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 650 W
Power Loss
at Rated Operating Conditions per Pole 32 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Main Circuit
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 28 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
5
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp | (200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 40 Hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 100 Hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 125 Hp | (550 ... 600 V AC) Three Phase 250 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF265-40 (Sweden)
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF265-40, AF305-40, AF370-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500505090
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707229
E-Number (Norway)
3210341
E-Number (Sweden)
3210341
Feature AF technology provides a wide control voltage range of 250–500 V AC (and DC) for reliable operation across fluctuating supply conditions → Business Impact Maintains consistent coil operation and reduces nuisance trips in networks with voltage variation → Application Ideal for OEMs and panel builders designing machines in regions with variable mains while minimizing energy waste. Feature Pre-mounted auxiliary contacts and main circuit bars simplify assembly and reduce panel wiring time → Business Impact Shorter wiring, faster commissioning, and lower assembly costs → Application Used in motor control panels where quick, reliable starter wiring is essential. Feature Block-type design with easy extension via add-on auxiliary contact blocks → Business Impact Scales with system needs without replacing the base unit, enabling future-proof control architectures → Application Suitable for evolving machinery and modular lines that require flexible I/O expansion. Feature Built-in surge protection protects contacts and reduces downtime from transient events → Business Impact Extends component life and lowers maintenance costs in harsh electrical environments → Application Common in conveyors, pumps, and fans in rugged production settings. Feature Rated Operational Current AC-3 up to 250–265 A at various voltages and 132 kW power at 415 V → Business Impact Supports high-power motor starts with compact footprint, reducing panel size and cooling needs → Application Suitable for large motors in packaging, material handling, and process lines. Feature Wide operating temperature and altitude ranges (−25 to 50 °C with O/L relay; up to 3000 m) → Business Impact Maintains reliability in outdoor or space-constrained installations; minimizes derating and spare parts. Feature Compliance framework (REACH, RoHS, WEEE B2B) and multiple certificates → Business Impact Ensures regulatory alignment, easier audits, and faster time-to-market for global deployments → Application Useful for multinational projects and sectors with strict material and environmental standards.

Get a Quick Quote for a ABB 1SFL547102R1411

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL547102R1411? Enquire Now

FAQs

Install the four-pole block contactor with the main circuit terminals utilizing the allowed flexible and rigid conductor sizes (2 x 70–185 mm² flexible, 1 x 185–240 mm² rigid). Follow the tightening torques for main circuit and cables (22–43 N·m) and ensure coil terminals are protected IP20 while main terminals are IP00. Use the built-in auxiliary contact blocks only when appropriate for control logic expansion to avoid overstressing control circuits.
In AC-3 service, the contactor delivers up to 265 A at 415–690 V and supports a rated operational power of up to 132 kW at 415 V. It offers a 8 x Ie breaking capacity and 10 x Ie making capacity, enabling reliable motor starting and switching while meeting IEC 60947-4-1 standards. Combined with solid surge protection, it minimizes contact wear during frequent switching.
Yes. The AF265-40-11-14 uses a block-type design that is easily extended with add-on auxiliary contact blocks. This allows you to tailor the control circuit to your machine logic without replacing the base unit, enabling scalable I/O and easier future expansion in automation lines.
The device carries CE and UL/CSA certifications, UKCA marking, and additional approvals such as EAC, CB, and others. These certifications support global market access and simplify compliance documentation for multinational projects in industries like food & beverage, packaging, and process automation.
The wide Uc control range (250–500 V AC, 50/60 Hz and DC) reduces the need for exact voltage stabilization, lowering energy waste in poorly regulated networks. In practice this can translate to lower panel energy consumption, fewer tripping events, and reduced maintenance across varying supply conditions, delivering a lower total cost of ownership over the life of the installation.