ABB 1SFL547262R1322 Contactor - UL/CSA 350 A
Part Number: 1SFL547262R1322
Quick Summary
ABB 1SFL547262R1322 Contactor controls motors up to 132 kW at 400 V AC. In busy manufacturing lines, voltage swings and panel energy waste often lead to nuisance trips and downtime. It carries CE, UL/CSA, and UKCA certifications, plus EAC and cURus marks for global compliance, ensuring reliable operation across regions. The AF technology enables a wide control voltage range and built-in surge protection, helping you reduce downtime, simplify panel design, and meet demanding efficiency targets. This makes it ideal for machine builders and panel shops seeking robust, scalable motor control.
Product Information
Extended Description
1SFL547262R1322 ABB: The AF265B-40-22RT-13 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 132 kW / 400 V AC (AC-3) / and switching power circuits up to 400 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A | (440 V) 55 °C 265 A | (500 V) 55 °C 250 A | (690 V) 55 °C 250 A | (380 / 400 V) 55 °C 265 A | (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 400 A | (100 V) 1 Pole, 60 °C 350 A | (100 V) 1 Pole, 70 °C 290 A | (110 V) 1-Pole, 40 °C 400 A | (110 V) 1-Pole, 60 °C 350 A | (110 V) 1-Pole, 70 °C 290 A | (110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (175 V) 2 Poles in Series, 40 °C 400 A | (175 V) 2 Poles in Series, 60 °C 350 A | (175 V) 2 Poles in Series, 70 °C 290 A | (200 V) 2 Poles in Series, 40 °C 400 A | (200 V) 2 Poles in Series, 60 °C 350 A | (200 V) 2 Poles in Series, 70 °C 290 A | (220 V) 2 Poles in Series, 40 °C 400 A | (220 V) 2 Poles in Series, 60 °C 350 A | (220 V) 2 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (260 V) 3 Poles in Series, 40 °C 400 A | (260 V) 3 Poles in Series, 60 °C 350 A | (260 V) 3 Poles in Series, 70 °C 290 A | (300 V) 3 Poles in Series, 40 °C 400 A | (300 V) 3 Poles in Series, 60 °C 350 A | (300 V) 3 Poles in Series, 70 °C 290 A | (340 V) 3 Poles in Series, 40 °C 400 A | (340 V) 3 Poles in Series, 60 °C 350 A | (340 V) 3 Poles in Series, 70 °C 290 A | (350 V) 4 Poles in Series, 40 °C 400 A | (350 V) 4 Poles in Series, 60 °C 350 A | (350 V) 4 Poles in Series, 70 °C 290 A | (400 V) 4 Poles in Series, 40 °C 400 A | (400 V) 4 Poles in Series, 60 °C 350 A | (400 V) 4 Poles in Series, 70 °C 290 A | (440 V) 4 Poles in Series, 40 °C 400 A | (440 V) 4 Poles in Series, 60 °C 350 A | (440 V) 4 Poles in Series, 70 °C 290 A | (72 V) 1-Pole, 40 °C 400 A | (72 V) 1-Pole, 60 °C 350 A | (72 V) 1-Pole, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A | (90 V) 1 Pole, 40 °C 400 A | (90 V) 1 Pole, 60 °C 350 A | (90 V) 1 Pole, 70 °C 290 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Power Loss
32 W | at Rated Operating Conditions per Pole 32 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp | (200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 40 Hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 100 Hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 125 Hp | (550 ... 600 V AC) Three Phase 250 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF265B..RT - AF370B-40...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF265B..RT - AF370B-40...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500510100
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
The four-pole AF265B-40-22RT-13 is designed as a compact block contactor with pre-mounted auxiliary contacts and ring tongue ferrules, reducing wiring complexity and installation time while delivering reliable motor control up to 132 kW at 400 V AC. The AF technology provides a broad control voltage range of 100–250 V for both AC and DC operation, enabling stable performance despite voltage fluctuations and helping to cut energy consumption in unstable networks. With built-in surge protection, it shields downstream electronics and minimizes unexpected trips, boosting line reliability in demanding automation environments. The block-type design supports straightforward expansion with add-on auxiliary contact blocks and a wide range of accessories, allowing scalable control schemes without redesigning the panel. Rated for AC-3 at high power, it supports 40 °C to 70 °C environments, ensuring long service life in industrial plants. Compatibility with standard barriers, bars for main terminals, and CAD data aids quick installation and reduces engineering time in panel shops.
Get a Quick Quote for a ABB 1SFL547262R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL547262R1322?
Enquire Now
FAQs
When installing the ABB AF265B-40-22RT-13, ensure four main NO contacts and two NO plus two NC auxiliary contacts are wired as required for your motor control scheme. Mount on a compatible DIN rail or panel, connect the main circuit bars to the rated terminals, and incorporate pre-mounted auxiliary blocks if needed. Verify coil voltage (100–250 V AC/DC) and respect ambient temperature limits (up to 70 °C) to maintain performance and longevity.
For AC-3 operation at 415 V, the device provides 265 A, and at 440–500 V ranges in the same class it remains around 250–265 A, depending on exact voltage and temperature. For AC-1, the ratings reach up to 350–400 A at 1000 V or 60–70 °C, with 300 A at 1000 V 60 °C and 240 A at 1000 V 70 °C. These figures support switching of large motors and general power circuits.
Yes. The AF265B-40-22RT-13 is rated for AC-3 applications up to 132 kW at 400 V, making it suitable for motor starters and direct-on-line or star-delta configurations in medium- to high-power drives. Its 4-pole main contact configuration, built-in surge protection, and AF technology help ensure reliable operation and protection for the motor and drive train.
The contactor carries CE, UL/CSA, UKCA, EAC, and cURus certifications, with RoHS, CMRT, and CCC/UK conformity documentation. This broad certification set supports regulatory compliance across Europe, North America, and emerging markets, helping you meet procurement requirements and reduce risk when sourcing from ABB.
AF technology delivers a wide control voltage range and improved tolerance to supply fluctuations, reducing nuisance trips and downtime. Built-in surge protection extends life for control circuits and downstream electronics, while a compact, scalable block design lowers panel space, wiring effort, and spare-part costs. Over the product lifecycle, this translates to predictable maintenance cycles and lower total cost of ownership.