ABB 1SFL547263R1122 Contactor - UL/CSA & CE Certified
Part Number: 1SFL547263R1122
Quick Summary
The ABB 1SFL547263R1122 Contactor is a four-pole motor starter designed to reliably switch heavy loads in industrial drives. Engineers often struggle with control voltage fluctuations that cause unnecessary wear and energy waste; AF technology in this device delivers a wide control voltage range and built-in surge protection to stabilize operations. It carries CE, UL/CSA and UKCA certifications, with RoHS/REACH declarations, ensuring regulatory alignment across global markets. With its modular block design, pre-mounted auxiliary contacts, and easy extendability, the solution supports scalable automation while delivering predictable maintenance costs and energy efficiency for motor control applications.
Product Information
Extended Description
1SFL547263R1122 ABB: The AF265B-40-22-11 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 132 kW / 400 V AC (AC-3) / and switching power circuits up to 400 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A | (1000 V) 60 °C 300 A | (1000 V) 70 °C 240 A | (690 V) 40 °C 400 A | (690 V) 60 °C 350 A | (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A | (440 V) 55 °C 265 A | (500 V) 55 °C 250 A | (690 V) 55 °C 250 A | (380 / 400 V) 55 °C 265 A | (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 400 A | (100 V) 1 Pole, 60 °C 350 A | (100 V) 1 Pole, 70 °C 290 A | (110 V) 1-Pole, 40 °C 400 A | (110 V) 1-Pole, 60 °C 350 A | (110 V) 1-Pole, 70 °C 290 A | (110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (175 V) 2 Poles in Series, 40 °C 400 A | (175 V) 2 Poles in Series, 60 °C 350 A | (175 V) 2 Poles in Series, 70 °C 290 A | (200 V) 2 Poles in Series, 40 °C 400 A | (200 V) 2 Poles in Series, 60 °C 350 A | (200 V) 2 Poles in Series, 70 °C 290 A | (220 V) 2 Poles in Series, 40 °C 400 A | (220 V) 2 Poles in Series, 60 °C 350 A | (220 V) 2 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (260 V) 3 Poles in Series, 40 °C 400 A | (260 V) 3 Poles in Series, 60 °C 350 A | (260 V) 3 Poles in Series, 70 °C 290 A | (300 V) 3 Poles in Series, 40 °C 400 A | (300 V) 3 Poles in Series, 60 °C 350 A | (300 V) 3 Poles in Series, 70 °C 290 A | (340 V) 3 Poles in Series, 40 °C 400 A | (340 V) 3 Poles in Series, 60 °C 350 A | (340 V) 3 Poles in Series, 70 °C 290 A | (350 V) 4 Poles in Series, 40 °C 400 A | (350 V) 4 Poles in Series, 60 °C 350 A | (350 V) 4 Poles in Series, 70 °C 290 A | (400 V) 4 Poles in Series, 40 °C 400 A | (400 V) 4 Poles in Series, 60 °C 350 A | (400 V) 4 Poles in Series, 70 °C 290 A | (440 V) 4 Poles in Series, 40 °C 400 A | (440 V) 4 Poles in Series, 60 °C 350 A | (440 V) 4 Poles in Series, 70 °C 290 A | (72 V) 1-Pole, 40 °C 400 A | (72 V) 1-Pole, 60 °C 350 A | (72 V) 1-Pole, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A | (90 V) 1 Pole, 40 °C 400 A | (90 V) 1 Pole, 60 °C 350 A | (90 V) 1 Pole, 70 °C 290 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A | (110 V) 2 Poles in Series, 60 °C 350 A | (110 V) 2 Poles in Series, 70 °C 290 A | (110 V) 3 Poles in Series, 40 °C 350 A | (110 V) 3 Poles in Series, 60 °C 350 A | (110 V) 3 Poles in Series, 70 °C 290 A | (220 V) 3 Poles in Series, 40 °C 350 A | (220 V) 3 Poles in Series, 60 °C 350 A | (220 V) 3 Poles in Series, 70 °C 290 A | (72 V) 2 Poles in Series, 40 °C 350 A | (72 V) 2 Poles in Series, 60 °C 350 A | (72 V) 2 Poles in Series, 70 °C 290 A | (72 V) 3 Poles in Series, 40 °C 350 A | (72 V) 3 Poles in Series, 60 °C 350 A | (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW | (380 / 400 V) 132 kW | (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
32 W | at Rated Operating Conditions per Pole 32 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp | (230 V AC) Three Phase 100 Hp | (460 V AC) Three Phase 200 Hp | (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA
(1000 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp | (200 V AC) Three Phase 75 hp | (208 V AC) Three Phase 75 hp | (220 ... 240 V AC) Three Phase 40 Hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 100 Hp | (440 ... 480 V AC) Three Phase 200 hp | (550 ... 600 V AC) Three Phase 125 Hp | (550 ... 600 V AC) Three Phase 250 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF265-40 (Sweden)
UL Certificate
cULus Certificate, Contactor, AF265-40, AF305-40, AF370-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500511107
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210476
Feature: Four-pole block contactor with AF technology. Business Impact: Handles motor loads up to 132 kW at 400 V AC-3, enabling reliable high-power switching with reduced fault exposure. Application: Ideal for large HVAC drives, pumps, and compressors where durable control is essential. Feature: Pre-mounted auxiliary contacts and standard ferrules. Business Impact: Simplifies wiring, shortens panel assembly time, and reduces field wiring errors. Application: Common in motor protection and control MCCs and starter cabinets. Feature: Wide coil voltage range of 24-60 V AC and 20-60 V DC. Business Impact: Tolerates voltage variations in unstable networks, decreasing nuisance tripping and energy waste. Application: Suitable for automation panels with variable supply conditions across manufacturing lines. Feature: Built-in surge protection. Business Impact: Extends contact life and protects drive electronics from transient events. Application: Essential in environments with electrical noise or motor startup surges. Feature: Modular AF design with add-on auxiliary contact blocks. Business Impact: Scales easily to changing control requirements without full redesign. Application: Flexible in growing MCCs and retrofits. Feature: Energy-conscious design and compliance anchors (RoHS/REACH, 5 million mechanical cycles). Business Impact: Reduces total cost of ownership through lower energy use and longer service intervals. Application: Fit for long-term industrial deployments in diverse markets.
Get a Quick Quote for a ABB 1SFL547263R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL547263R1122?
Enquire Now
FAQs
Install the 4-pole block contactor using the main circuit bars, with the pre-mounted auxiliary contacts accessible for wiring. Ensure panel clearance for 225 mm height and secure mounting per manufacturer torque specs. Use the AF technology coil range (24-60 V AC or 20-60 V DC) for reliable pull-in and consider adding auxiliary contact blocks to match control circuit needs.
Rated operational power for AC-3 is up to 132 kW at 415-440/380-400 V, with current ratings around 265 A at 55 °C for 415–690 V variants. The device supports up to 400 A in AC-1 configurations and provides robust switching with 5 million mechanical cycles and a maximum of 300 cycles per hour, suitable for high-demand motor drives.
The unit carries CE and UL/CSA certifications with UKCA recognition for the rail and industrial market. It also adheres to RoHS and REACH declarations, plus TSCA and CCC/UK conformity in applicable regions, ensuring safe operation and regulatory compliance across major global markets.
Coil voltage is available as 24-60 V AC (50/60 Hz) or 20-60 V DC. Coil consumption includes 8.5 VA holding at max rated voltage, 475 VA pull-in at 50/60 Hz, and 400 W DC pull-in, with overall power loss of 32 W per pole under rated conditions.
Product net width is 184 mm, depth 180 mm, and height 225 mm, with a net weight of 5.7 kg. Packaging dimensions for Level 1 include 212 mm width, 262 mm depth, and 212 mm height with a gross weight of 6.4 kg. These specs help plan enclosure space and mounting clearances in MCCs and control cabinets.