ABB 1SFL557001R6922 Block Contactor is a three-phase motor-control device designed for starting, isolation, and distribution in demanding industrial environments. Operators often face wide control-voltage swings, cramped panels, and the need for rapid maintenance, which this device helps address with a broad 48–130 V control range and easy-to-wire terminations. This unit carries CE conformity and UL/CSA approvals, and features IP20 coil terminals with IP00 main terminals, supporting safe operation in diverse markets. With a 690 V main circuit rating and 50/60 Hz operation, it provides reliable, high-current switching while minimizing panel complexity and downtime. The result is improved line uptime, lower lifecycle costs, and greater design flexibility for motor-control applications.

Product Information

Extended Description

1SFL557001R6922 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL587002R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 500 A | (690 V) 55 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 300 A | (440 V) 55 °C 280 A | (500 V) 55 °C 280 A | (690 V) 55 °C 280 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 18 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 400 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 100 hp | (208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69480
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115200
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.75 kg
Package Level 1 EAN
7320500222980
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Three-pole construction delivers reliable motor starting up to 690 V with a rated operational current up to 500 A AC-1 and 280–305 A AC-3 depending on voltage, enabling high-demand drives in pumps, fans, and conveyors. This translates to fewer nuisance trips, faster commissioning, and a smaller control panel footprint. The coil accepts 48–130 V across AC or DC, reducing wiring variety and enabling seamless integration with broader automation architectures; coil consumption values balance holding power and pull-in performance to improve overall system efficiency. With 2 auxiliary NO and 2 NC contacts and main contacts NO=3, this cont actor supports interlocking, signaling, and safe shutdown routines without added modules, cutting wiring time and space requirements. Robust mechanical durability (up to 5 million cycles) and a rated short-time withstand current matrix enhance reliability in harsh environments, while nominal tightening torque (28 N·m) and clear terminal wiring (Bars or solid Cu/Al cables) simplify installation. Certifications including CE and UL/CSA, RoHS compliance, and IP ratings provide regulatory assurance across global sites, reducing compliance risk and enabling faster design validation. Finally, compatible connection options—32 mm² main circuit, 2 x 95–120 mm² rigid cables, and flexible auxiliary conductors—enable straightforward upgrades in legacy panels without costly rewiring.

Get a Quick Quote for a ABB 1SFL557001R6922

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL557001R6922? Enquire Now

FAQs

Mounting requires securing the device with the standard 28 N·m tightening torque on main circuit terminals and using appropriate Bar 32 mm² or rigid Cu/Al cable connections as specified. Maintain IP20 protection for coil terminals and IP00 for main terminals. Plan wiring to minimize bending and ensure proper clearance for heat dissipation and future maintenance.
Rated Operational Current Ie up to 500 A AC-1 and 280–305 A AC-3 at 690 V, depending on temperature. Insulation voltage Ui is 1000 V, and coil operating voltage Uc covers 48–130 V for AC and DC operation. These ratings support reliable motor starting and distribution in high-voltage installations.
Yes. It is designed for three-phase motor control with mains up to 690 V and supports AC-3 duty at common industrial voltages including 400–440 V ranges. Its wide coil range and high current ratings enable robust motor starting and protection for 3P equipment in typical plant environments.
The device carries CE conformity and UL/CSA approvals with RoHS compliance. It also has multiple third-party certificates (ABS, BV, DNV GL, RTN variants, RINA, GL) attesting to safety and reliability across global markets, making it suitable for regulated industries and multinational projects.
Main circuit connections use bars with a 32 mm² capacity or rigid Cu/Al cables up to 240 mm², while auxiliary circuits support flexible conductors (0.75–2.5 mm² ferrule or solid 1–4 mm²). This versatility simplifies integration with existing panels and reduces installation time while ensuring strong, vibration-resistant terminations.