ABB 1SFL557001R7011 Block Contactor - CE/UL Listed
Part Number: 1SFL557001R7011
Quick Summary
Block Contactor ABB 1SFL557001R7011 starts motors securely in 3-phase systems up to 690 V. It is designed to handle motor starting, isolation, bypass and distribution tasks in industrial panels. Many engineers face control voltage variability; this unit operates from 100–250 V AC/DC, reducing wiring changes and field adjustments. The device carries CE declarations and UL/CSA ratings, with additional approvals from GL, BV and DNV GL to support global machinery compliance. For panel builders and OEMs, it means faster installations, safer switching, and predictable spare parts across projects, while meeting stringent safety and performance standards. This combination of robust performance and broad certification provides a reliable platform for your electrical protection and circuit control needs.
Product Information
Extended Description
1SFL557001R7011 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL587002R1311
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.1 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 500 A | (690 V) 55 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 300 A | (440 V) 55 °C 280 A | (500 V) 55 °C 280 A | (690 V) 55 °C 280 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 18 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 400 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 100 hp | (208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-69480
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115200
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
7320500220344
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3709249
E-Number (Norway)
4115283
E-Number (Sweden)
3228326
Feature → Business Impact → Application: This 3-pole block contactor features 3 main NO contacts and 1 NO plus 1 NC auxiliary contact, enabling streamlined control circuits for motor starting, isolation, bypass and distribution in a single device. Benefit: reduces panel complexity and wiring errors, while increasing reliability in high-demand drives. Application: ideal for heavy-load conveyors, pumps, and fans where space and performance matter. Feature: Coil voltage range of 100–250 V AC/DC. Benefit: simplifies integration with varied control systems and reduces inventory by supporting multiple control supplies. Application: OEMs and integrators can standardize on a single device across multiple projects. Feature: Rated main circuit voltage up to 690 V and 50/60 Hz operation. Benefit: supports wide industrial power networks with high short-time withstand performance. Application: motor starters in multi-voltage facilities. Feature: Flexible connecting capacities for main and auxiliary circuits (Bar 32 mm²; Cu-Al cables 16–240 mm²; auxiliary 0.75–2.5 mm²). Benefit: easier wiring, faster commissioning, and reduced labor costs. Application: panel builders and field installers. Feature: IP20 protection at coil terminals and IP00 at main terminals; tightening torque 28 N·m. Benefit: safer handling and secure terminations in tight panels. Application: electrical panels in machine rooms or production lines. Feature: Mechanical durability of 5 million cycles and robust insulation ratings. Benefit: minimizes maintenance intervals and extends lifecycle cost efficiency. Application: critical manufacturing environments with high duty cycles.
Get a Quick Quote for a ABB 1SFL557001R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL557001R7011?
Enquire Now
FAQs
Begin by confirming coil voltage 100-250 V and mains rating up to 690 V. Mount using 28 N·m tightening torque on main terminals; wire main circuit with Bar 32 mm² or Cu/Al cables 16-240 mm²; connect auxiliary circuit flexible 0.75–2.5 mm². Dimensions 140x180.5x227 mm; weight 5.1 kg; IP20 coil terminal protection.
AC-1 at 690 V/40 °C: 500 A; at 55 °C: 400 A; at 70 °C: 325 A. AC-3 at 415 V/55 °C: 300 A; 440 V/55 °C: 280 A; 500 V/55 °C: 280 A; 690 V/55 °C: 280 A; 380/400 V/55 °C: 305 A; 220/230/240 V/55 °C: 305 A.
Yes. It is a 3-pole block contactor with 3 main NO contacts and 1 NO + 1 NC auxiliary contact, designed for motor starting, isolation, bypass and distribution up to 690 V. It supports 100–250 V control, 50/60 Hz operation, and offers up to 5 million mechanical cycles, making it suitable for demanding industrial drives and panel systems.
The device carries CE declarations and UL/CSA ratings, along with approvals from GL, BV, LR, RINA, DNV GL, ABS and other major bodies. This mix supports European, North American and international compliance, helping you meet safety and performance standards across global markets and reducing qualification time for new deployments.
With 5 million mechanical cycles and robust insulation, the 1SFL557001R7011 offers long service life with minimal maintenance when operated within rated conditions. Regularly inspect connections and verify tightening torque of 28 N·m to prevent overheating. For lifecycle planning, consider the replacement option 1SFL587002R1311 when upgrading or expanding motor control in evolving panels.