ABB 1SFL557063R6911 Block Contactor - IEC/UL/CE Certified 690V

Part Number: 1SFL557063R6911
Manufacturer
ABB
Part number
1SFL557063R6911

Quick Summary

ABB 1SFL557063R6911 Block Contactor is a 3-pole device designed for rail and heavy automation applications, with a 48–130 V coil and a main circuit rated up to 690 V. This combination delivers flexible control across AC and DC systems while enabling reliable high-current switching in demanding environments. Operators often struggle with matching coil voltage to control circuits and with ensuring robust protection for high-energy loads; this model addresses that by supporting 50/60 Hz operation and a wide coil range, reducing the need for multiple part numbers. It carries CE, UL/CSA, and CCC-style certifications, reinforcing compliance in international projects. By pairing compact form with scalable current ratings, it helps reduce spare parts and simplifies procurement for OEMs and MRO teams.

Product Information

Extended Description

1SFL557063R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL587063R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A145, A185, A210, A260, A300
Dimension Diagram
53540930-2
Product Net Width
140 mm
Product Net Depth / Length
180.5 mm
Product Net Height
227 mm
Product Net Weight
5.5 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 500 A | (690 V) 55 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 300 A | (440 V) 55 °C 280 A | (500 V) 55 °C 280 A | (690 V) 55 °C 280 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Loss
at Rated Operating Conditions per Pole 18 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 ... 50 ms | Between Coil De-energization and NO Contact Opening 43 ... 53 ms | Between Coil Energization and NC Contact Opening 45 ... 85 ms | Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 32 mm² | Rigid Al-Cable 120 ... 240 mm² | Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 32 mm² | Rigid Al-Cable 2 x 95 ... 120 mm² | Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
Flat type c/w screws and bolts
Tightening Torque
Main Circuit 28 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 400 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 100 hp | (208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 100 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-69480
CQC Certificate
CQC Certificate, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF210, AF210B…RT, AF260, AF260B…RT, AF300, AF300B…RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20262-04HH
LOVAG Certificate
SE-0115200
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
203 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Height
188 mm
Package Level 1 Gross Weight
6.2 kg
Package Level 1 EAN
7320500258453
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Coil voltage flexibility drives installation efficiency and stock optimization. Feature → Business Impact → Application: The 48–130 V AC/DC coil range allows seamless integration with existing control circuits, cutting wiring complexity and reducing part variety in rail and industrial panels. This translates to faster commissioning and lower total cost of ownership in rolling stock and fixed installations. Feature → Business Impact → Application: Wide main-circuit rating up to 690 V enables direct motor and drive control for large loads without swapping devices, improving uptime and reducing panel footprint in substations and switchgear assemblies. Feature → Business Impact → Application: Three main NO contacts plus one NO and one NC auxiliary contact simplify interlocking and control logic, reducing wiring harness length and potential fault points in conveyors and rail signaling systems. Feature → Business Impact → Application: Integrated protection and coordination with gG-type fuses (500 A) and high short-time withstand capabilities improve safety margins and compliance with global standards for high-energy circuits. Feature → Business Impact → Application: Flexible connectivity with Bar 32 mm² main conductors and 16–240 mm² rigid Cu/Al cables provides installation versatility, enabling clean, code-compliant terminations in both retrofit and new-build projects. Feature → Business Impact → Application: Robust mechanical durability (millions of cycles) lowers maintenance cost and extends service life in harsh environments typical of railways and industrial drives. Feature → Business Impact → Application: Energy-efficient coil operation with defined pull-in and holding values supports lower energy use across duty cycles, beneficial in systems with frequent switching and long idle periods.

Get a Quick Quote for a ABB 1SFL557063R6911

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL557063R6911? Enquire Now

FAQs

Install by mounting the 3P block contactor in a suitable enclosure, connect the main circuit using bars (32 mm²) or rigid Cu/Al cables (16–240 mm²), and secure auxiliary circuits per the provided terminal layout. Torque main circuit terminals to 28 N·m and ensure IP20 coil terminals with proper wiring practice for safe operation.
For AC-1 at 690 V, Ie is 500 A at 40 °C, 400 A at 55 °C, and 325 A at 70 °C. For AC-3, ratings vary by voltage: at 415 V 55 °C, Ie = 300 A; at 440–690 V ranges, Ie is 280–305 A. These figures support reliable motor starting and running in high-demand applications.
Yes. It is designed for rail applications with a 3P configuration, 48–130 V coil control, and a main circuit up to 690 V. Certifications and conformance to IEC/EN 60947-4-1 and related standards, plus UL/CSA and CCC documentation, ensure performance and regulatory compliance for rail systems and related rolling stock equipment.
The unit carries CE Declaration of Conformity, UL/CSA listings, CCC, and other certificates including BV, LR, GL, RINA, and RMRS. This broad certification profile supports global procurement and ensures compliance across rails, industrial drives, and electrical machinery.
Main circuit terminals accept bars up to 32 mm² or rigid Cu/Al cables from 16 to 240 mm². Auxiliary circuits accept flexible conductors with ferrules (0.75–2.5 mm²), solid (1–4 mm²), or stranded (2–4 mm²). The product ships with flat main terminals and a 28 N·m tightening torque, simplifying installation and ensuring secure, high-current connections.