ABB 1SFL577001R7111 Contactor - 1000 V IEC UL

Part Number: 1SFL577001R7111
Manufacturer
ABB
Part number
1SFL577001R7111

Quick Summary

ABB AF400 Contactor is a high-capacity motor switch used to control three-phase motors in industrial plants. In networks with voltage fluctuations, its AF technology tolerates 250-500 V AC or DC control signals, reducing misoperation and panel energy waste. The device carries CE declarations and UL/CSA listings, backed by robust 1000 V insulation and built-in surge protection. With IP20 coil terminals and IP00 main terminals, it fits safely into standard control panels. Its compact, block-style design can be extended with add-on auxiliary contact blocks and accessories, enabling scalable motor control as system requirements evolve.

Product Information

Extended Description

1SFL577001R7111 ABB: The AF400-30-11-71 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-59
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 600 A | (1000 V) 55 °C 500 A | (1000 V) 70 °C 400 A | (690 V) 40 °C 600 A | (690 V) 55 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 400 A | (440 V) 55 °C 400 A | (500 V) 55 °C 400 A | (690 V) 55 °C 350 A | (1000 V) 55 °C 155 A | (380 / 400 V) 55 °C 400 A | (220 / 230 / 240 V) 55 °C 400 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 600 A | (110 V) 2 Poles in Series, 40 °C 600 A | (220 V) 3 Poles in Series, 40 °C 600 A | (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 600 A | (110 V) 2 Poles in Series, 40 °C 600 A | (220 V) 3 Poles in Series, 40 °C 600 A | (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 600 A | (110 V) 2 Poles in Series, 40 °C 600 A | (220 V) 3 Poles in Series, 40 °C 600 A | (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Power AC-3 (Pe)
(415 V) 220 kW | (440 V) 220 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 220 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 950 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 950 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 885 V·A
Power Loss
at Rated Operating Conditions per Pole 16 W
Operate Time
Between Coil De-energization and NC Contact Closing 45 ... 55 ms | Between Coil De-energization and NO Contact Opening 48 ... 58 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 47 mm² | Rigid Al-Cable 240 mm² | Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 47 mm² | Rigid Al-Cable 2x240 mm² | Rigid Cu-Cable 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 35 N·m | Main Circuit 35 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 550 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 125 hp | (208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 350 hp | (550 ... 600 V AC) Three Phase 400 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 414 A | (550 ... 600 V AC) Three Phase 382 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)400(B)-**;AF(S)460(B)-**;AF460N6
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82316
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF400, AF460, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF400, AF460, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV_E-10966
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_42988-02HH
LOVAG Certificate
SE-0146190
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF400, AF460, AFS400, AFS460
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Package Level 1 EAN
7320500250006
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3709250
E-Number (Norway)
4115289
E-Number (Sweden)
3228335
Feature: Wide control voltage range 250-500 V AC/DC → Business Impact: Enables stable operation across fluctuating supply conditions, reducing panel energy waste and electrical noise in harsh environments; Application: Motor starters in conveyors, pumps, and HVAC systems. Feature: Three main contacts plus one NO and one NC auxiliary contact → Business Impact: Simplified wiring and improved control logic, enabling safer and more reliable startup sequences in automation panels; Application: 3P motor switching in heavy-duty lines. Feature: Built-in surge protection → Business Impact: Minimizes external protection components, reducing BOM cost and panel space while increasing reliability; Application: Critical motor drives in manufacturing lines. Feature: Block-type, expandable design with add-on auxiliary blocks → Business Impact: Scales with growing control needs without replacing hardware; Application: Modular motor control cabinets. Feature: High rated current and power capabilities (AC-3 up to 400 A at various voltages) → Business Impact: Supports large motor loads with fewer devices, lowering installation complexity and downtime. Feature: Coil consumption and operating limits → Business Impact: Predictable energy usage and thermal performance, aiding panel cooling design. Feature: RoHS/REACH compliant and multiple certifications → Business Impact: Simplified compliance across regions and faster time-to-market for global projects. Feature: Robust mechanical durability (up to 3 million cycles) → Business Impact: Longer lifetime and lower maintenance costs in demanding industrial environments. Feature: IP20 coil terminals, IP00 main terminals → Business Impact: Safer wiring in control panels with predictable protection class; Application: Standard rack-mounted enclosures. Feature: Easy compatibility with ABB accessories and installation tooling → Business Impact: Faster panel assembly and future upgrades, reducing project lead times.

Get a Quick Quote for a ABB 1SFL577001R7111

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL577001R7111? Enquire Now

FAQs

The AF400-30-11 is a 3-pole block contactor rated for AC-3 operation with high current capability (up to 600 A main at 1000 V). It is designed to integrate with ABB pre-mounted auxiliary contacts and add-on contact blocks, enabling scalable motor control for fans, pumps, conveyors, and other heavy-duty loads.
Yes. The coil control range is 250–500 V for AC 50/60 Hz and 250–500 V for DC operation. The coil consumption varies with state: holding at max rated voltage around 12 V·A (50/60 Hz) and pull-in at max voltage up to 950–885 V·A, ensuring reliable operation across voltage fluctuations.
The device is specified as a 3P block contactor with pre-mounted main circuit bars, supporting motors up to 200 kW at 400 V AC (AC-3) and 350 hp at UL ratings. Its dimensions and 10.6 kg weight, along with IP20/IP00 protection, make it straightforward to install in standard control panels and easily integrate with busbars and wiring harnesses.
This AF400 family includes CE declarations and UL/CSA certifications, plus a suite of environmental and safety declarations such as RoHS, REACH, and DNV/GL or LR certificates where applicable. It is designed for global compliance, supporting safe operation in diverse regulatory contexts.
With a long mechanical durability rating of up to 3 million cycles, built-in surge protection, and a compact block design that reduces wiring and panel space, the AF400 lowers maintenance intervals and spare-part costs. Its wide control voltage tolerance also reduces nuisance tripping from supply variations, improving uptime and overall equipment effectiveness.