ABB 1SFL587002R4200 Block Contactor - UL/CSA 1000V
Part Number: 1SFL587002R4200
Quick Summary
ABB 1SFL587002R4200 Block Contactor is a 3-pole motor starter engineered for 1000 V mains and AC-3 duty in industrial drives. In real plants, coil voltage compatibility, fast operation, and energy efficiency are constant challenges that affect uptime and operating cost. The device carries CE declarations and UL/CSA listings, plus RoHS and REACH compliance to support global deployment. This solution also delivers a compact AF technology platform with easy expansion via auxiliary contact blocks, reducing panel space and BOM complexity. Its built-in surge protection and robust mechanical life contribute to reliable plant performance and lower total cost of ownership across demanding applications.
Product Information
Extended Description
1SFL587002R4200 ABB: The AF305-30-00-42 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 160 kW / 400 V AC (AC-3) or 250 hp / 480 V UL and switching power circuits up to 500 A (AC-1) or 400 A UL general use. Thanks to the AF technology, the contactor has a control voltage range (110-120 V 50/60 Hz),faster operation time, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A | (1000 V) 60 °C 325 A | (1000 V) 70 °C 260 A | (690 V) 40 °C 500 A | (690 V) 60 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 305 A | (440 V) 60 °C 305 A | (500 V) 60 °C 290 A | (690 V) 60 °C 290 A | (1000 V) 60 °C 131 A | (380 / 400 V) 60 °C 305 A | (220 / 230 / 240 V) 60 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (1000 V) 185 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 ... 120 V | 60 Hz 110 ... 120 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 50 W | at Rated Operating Conditions AC-3 per Pole 19 W
Operate Time
Between Coil De-energization and NO Contact Opening 20 ... 30 ms | Between Coil Energization and NO Contact Closing 20 ... 35 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 400 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 125 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 285 A | (220 ... 240 V AC) Three Phase 312 A | (440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561102
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
AF technology enables faster operate times and lower panel energy consumption, improving overall drive efficiency and reducing heat generation in motor control panels. This translates to measurable energy savings and cooler installations in automated production lines where uptime is critical. The AF305-30-00-42 supports a 3-pole main circuit rated at 1000 V, delivering up to 131 A AC-3 at 60 °C and up to 185 kW Pe at 1000 V, enabling efficient control of large motors with minimal voltage drop. Built-in surge protection simplifies protection schemes and reduces external components, while the block-type design allows straightforward expansion with add-on auxiliary contact blocks for custom signaling and interlocks. The contactor also offers compatible wiring options: flexible 0.75–2.5 mm² for auxiliary circuits and large cross-sections for main circuits, simplifying installation in varied panel layouts. With a compact footprint (140 mm W, 180 mm D, 225 mm H) and IP20/ IP00 terminals, it is well suited to space-constrained installations. The device’s operating range from −25 to 55 °C (with or without an thermal overload relay) and altitude up to 3000 m ensures stable operation in diverse environments. Safety and regulatory compliance are reinforced by CE, UL/CSA, RoHS, and REACH conformance, helping you meet global procurement requirements while maintaining reliability. This combination supports predictable maintenance planning, reduces downtime risk, and enhances footprint efficiency in industries such as HVAC, pumps, conveyors, and machine tools.
Get a Quick Quote for a ABB 1SFL587002R4200
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL587002R4200?
Enquire Now
FAQs
Install the device in a panel, mount the block contacor and connect the main circuit using flexible cables 2 x 70–185 mm² or rigid Al/Cu options 1 x 185–240 mm² as specified. Wire the control circuit to 110–120 V AC at 50/60 Hz and adhere to the recommended control terminal torque of 1 N·m. For auxiliary circuits, use the recommended ferrule wiring (0.75–2.5 mm²) and observe the auxiliary terminal torque of 1 N·m; main circuit torque should be 22–43 N·m. Ensure IP20 coil terminals and IP00 main terminals are properly sealed and the device is secured for safe operation.
For 1000 V main circuit, the Rated Operational Current AC-3 (Ie) is 131 A at 60 °C. The corresponding AC-1 current rating is 375 A at 60 °C. The device can deliver up to 185 kW output at 1000 V under AC-3 conditions, making it suitable for starting and running larger motors with reliable switching performance in industrial environments.
Yes. The contactor carries CE declarations and UL/CSA certifications, with RoHS and REACH declarations for restricted substances and lifecycle compliance. It also aligns with WEEE guidelines for B2B environments, supporting safe disposal and recycling. This makes it suitable for global deployments in regulated industries such as machinery, HVAC, and material handling.
The contactor offers a mechanical durability of up to 5 million operations with a maximum mechanical switching frequency of 300 cycles per hour. Maintenance considerations include checking coil voltage, inspecting connections for secure torque, and monitoring for wear on the main circuit bars. Built-in surge protection reduces external components and simplifies preventive maintenance, contributing to lower total cost of ownership over time.
Yes. The AF305-30-00-42 features a block-type design that supports easy expansion with add-on auxiliary contact blocks and a wide range of accessories. This enables enhanced signaling, interlocking, and control configurations while maintaining a compact footprint. The installation remains straightforward, provided you follow the wiring and torque specifications for both main and auxiliary circuits.