ABB 1SFL587002R4222 Block Contactor - 1000 V IEC/UL
Part Number: 1SFL587002R4222
Quick Summary
The ABB 1SFL587002R4222 Block Contactor controls high-current motors in industrial automation. In fluctuating networks, reliable motor start-up and reduced energy waste are common challenges, and this device is designed to address them with AF technology and built-in surge protection. It complies with CE, UL/CSA, and UKCA declarations, providing confidence across markets and across safety audits. The product also supports extended configurations via add-on auxiliary contact blocks, making it adaptable for varying control schemes. This combination of protection, efficiency, and modularity translates into lower commissioning costs and easier maintenance for systems ranging from generic conveyors to heavy-duty presses.
Product Information
Extended Description
1SFL587002R4222 ABB: The AF305-30-22-42 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 160 kW / 400 V AC (AC-3) or 250 hp / 480 V UL and switching power circuits up to 500 A (AC-1) or 400 A UL general use. Thanks to the AF technology, the contactor has a control voltage range (110-120 V 50/60 Hz),faster operation time, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
160 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A | (1000 V) 60 °C 325 A | (1000 V) 70 °C 260 A | (690 V) 40 °C 500 A | (690 V) 60 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 305 A | (440 V) 60 °C 305 A | (500 V) 60 °C 290 A | (690 V) 60 °C 290 A | (1000 V) 60 °C 131 A | (380 / 400 V) 60 °C 305 A | (220 / 230 / 240 V) 60 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (1000 V) 185 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 ... 120 V | 60 Hz 110 ... 120 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 50 W | at Rated Operating Conditions AC-3 per Pole 19 W
Operate Time
Between Coil De-energization and NO Contact Opening 20 ... 30 ms | Between Coil Energization and NO Contact Closing 20 ... 35 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 400 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 125 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 285 A | (220 ... 240 V AC) Three Phase 312 A | (440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561126
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: AF technology delivers faster operation times and reduced panel energy consumption, improving line efficiency and motor response in high-cycle environments such as plastics extrusion or metalworking. Application: Use in AF-based starter assemblies to minimize start-up transients while preserving electrical life. Feature → Proven motor protection and surge resilience → Benefit: Built-in surge protection reduces nuisance trips and protects downstream electronics, cutting downtime and service costs in environments with power quality issues. Application: Suitable for food processing lines and packaging where voltage sags are common. Feature → 3P main contacts and 3 NO / 2 NO auxiliary contacts → Benefit: Greater control flexibility for complex motor wiring and interlocks, enabling safe interconnection with overload relays and control circuits. Application: Ideal for cascading control schemes in packaging and material handling. Feature → 1000 V insulation and UL/CSA/CE/UKCA certifications → Benefit: Compliance across global markets supports faster procurement cycles and reduces certification workload for OEMs. Application: Aerospace, automotive suppliers, and machine builders shipping internationally. Feature → Modular design with add-on auxiliary blocks → Benefit: Easy expansion without redesigned panels, lowering retrofit costs and simplifying spare part management. Application: Retrofit projects and scalable automation lines. Feature → Compact block design with IP20 coil terminals and IP00 main terminals → Benefit: Easier panel integration, cleaner wiring, and improved enclosure density. Application: Control cabinets in compact machines and converters.
Get a Quick Quote for a ABB 1SFL587002R4222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL587002R4222?
Enquire Now
FAQs
This 3-pole block cont ator uses main circuit bars with compatibility for auxiliary contact blocks. It supports flexible connections for both flexible and solid conductors, including 0.75–2.5 mm² ferrule options for auxiliary circuits and 1–4 mm² solid or stranded conductors for control and main circuits. The coil terminals are IP20 protected, while main terminals present IP00 protection, simplifying layout planning and panel wiring while enabling straightforward expansion with add-on auxiliary blocks for increased control functionality.
For AC-1 operation at 1000 V, Ie values vary with ambient temperature (375 A at 40 °C, 325 A at 60 °C, 260 A at 70 °C). For AC-3, Ie values include 131 A at 1000 V and up to 305 A at various lower voltages (e.g., 415–690 V). Rated operational power (AC-3) ranges up to 185–250 kW depending on voltage; the device also supports a maximum breaking capacity and short-time withstand currents suitable for high-demand motor loads.
Yes. With 3P main contacts and 1000 V insulation, it supports motors up to 160 kW (AC-3 at high voltage) and is designed for reliable operation in industrial HVAC or pump drives. Its compact AF technology delivers rapid switching and surge protection, while the ability to add auxiliary blocks enables integration with interlocks and overload relays. Its protective IP20 coil terminals and IP00 main terminals aid installation in standard control cabinets.
The unit carries CE Declaration of Conformity and UKCA labeling, along with UL/CSA certification for main circuit voltage up to 1000 V. RoHS and REACH declarations are provided, and WEEE guidance is oriented toward B2B uses. UL certificates cover specific models in the AF265–AF370 family, ensuring compliance for global product launches and equipment intended for international markets.
AF technology provides faster release and reset times, reducing energy losses per cycle and improving reliability in networks with voltage fluctuations. The device exhibits 5 million mechanical cycles of durability and built-in surge protection to minimize nuisance trips. Maintenance intervals can be extended, total cost of ownership is lowered, and overall uptime improves in production lines with frequent motor start-stop sequences.