ABB 1SFL587063R1322 Block Contactor - IEC/UL 60947-4-1
Part Number: 1SFL587063R1322
Quick Summary
ABB 1SFL587063R1322 Block Contactor is a three‑pole device for motor control and heavy loads in industrial panels. Engineers often deal with voltage fluctuations and wasted energy, which can lead to unreliable starts and higher utility costs; this AF‑technology solution is engineered to tolerate wide control voltage ranges (100–250 V AC/DC) while delivering stable operation. Certified to IEC/EN 60947‑1, IEC/EN 60947‑4‑1, and UL 60947‑4‑1, with UL/CSA general-use ratings and CE/UKCA declarations, it supports global deployments. With pre-mounted auxiliary contacts and easy extension with add‑on blocks, it offers a compact, energy‑efficient solution that simplifies installation and reduces maintenance burdens for panel builders and end users.
Product Information
Extended Description
1SFL587063R1322 ABB: The AF305B-30-22-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 160 kW / 400 V AC (AC-3) or 250 hp / 480 V UL and switching power circuits up to 500 A (AC-1) or 400 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF265, AF305,AF370
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A | (1000 V) 60 °C 325 A | (1000 V) 70 °C 260 A | (690 V) 40 °C 500 A | (690 V) 60 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A | (440 V) 55 °C 305 A | (500 V) 55 °C 290 A | (690 V) 55 °C 290 A | (1000 V) 55 °C 100 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 500 A | (100 V) 1 Pole, 60 °C 400 A | (100 V) 1 Pole, 70 °C 325 A | (110 V) 1-Pole, 40 °C 500 A | (110 V) 1-Pole, 60 °C 400 A | (110 V) 1-Pole, 70 °C 325 A | (110 V) 2 Poles in Series, 40 °C 500 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 500 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (175 V) 2 Poles in Series, 40 °C 500 A | (175 V) 2 Poles in Series, 60 °C 400 A | (175 V) 2 Poles in Series, 70 °C 325 A | (200 V) 2 Poles in Series, 40 °C 500 A | (200 V) 2 Poles in Series, 60 °C 400 A | (200 V) 2 Poles in Series, 70 °C 325 A | (220 V) 2 Poles in Series, 40 °C 500 A | (220 V) 2 Poles in Series, 60 °C 400 A | (220 V) 2 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 500 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (260 V) 3 Poles in Series, 40 °C 500 A | (260 V) 3 Poles in Series, 60 °C 400 A | (260 V) 3 Poles in Series, 70 °C 325 A | (300 V) 3 Poles in Series, 40 °C 500 A | (300 V) 3 Poles in Series, 60 °C 400 A | (300 V) 3 Poles in Series, 70 °C 325 A | (340 V) 3 Poles in Series, 40 °C 500 A | (340 V) 3 Poles in Series, 60 °C 400 A | (340 V) 3 Poles in Series, 70 °C 325 A | (72 V) 1-Pole, 40 °C 500 A | (72 V) 1-Pole, 60 °C 400 A | (72 V) 1-Pole, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 500 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 500 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A | (90 V) 1 Pole, 40 °C 500 A | (90 V) 1 Pole, 60 °C 400 A | (90 V) 1 Pole, 70 °C 325 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (1000 V) 185 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Power Loss
19 W | at Rated Operating Conditions per Pole 19 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 400 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 125 hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 285 A | (220 ... 240 V AC) Three Phase 312 A | (440 ... 480 V AC) Three Phase 302 A | (550 ... 600 V AC) Three Phase 289 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SE-89316
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500511046
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210454
Feature AF technology delivers a wide control voltage range, improving reliability in networks with voltage fluctuations. Business Impact This reduces misoperation and energy waste, lowering panel energy consumption and maintenance costs. Application Use this in motor control circuits for pumps, conveyors, and fans where supply conditions vary; it enables consistent starts and fewer faults. Feature Built‑in surge protection and a compact block design allow easy integration in tight panels and safer wiring. Business Impact The built‑in protection reduces separate surge devices, saving space and installation time. Application Suitable for new builds or retrofits in existing control panels. Feature Auxiliary contacts (2 NO / 2 NC) extend control strategies and interlocking options. Business Impact Enables more complex control logic, fault signaling, and safer interlocks without additional components. Application Perfect for motor protection schemes needing signaling and auxiliary feedback. Feature 3P main contacts with 1000 V rating and 375 A AC‑1 / 305 A AC‑3 ratings at various temperatures. Business Impact Supports motors up to 160 kW at 400 V AC and 250 hp at UL ratings, enabling high‑power applications with fewer devices. Application Commonly used in heavy machinery and processing lines. Feature Coil voltage range 100–250 V AC/DC and AF technology for reduced energy draw. Business Impact Lowers coil energy consumption and improves panel heat management. Application Beneficial in energy‑aware or battery‑backed control systems. Feature Mechanical durability rated at 5 million operations and a maximum mechanical switching frequency of 300 cycles per hour. Business Impact Improves long‑term reliability and reduces replacement cycles in high‑duty environments. Application Suitable for 24/7 operations in packaging, material handling, and processing lines. Feature Dimensions and weight (140 mm width, 180 mm depth, 225 mm height; 3.9 kg) support compact installations. Business Impact Frees up panel space and simplifies enclosure design. Application Fits standard cabinet layouts and is compatible with add‑on auxiliary contact blocks. Feature Compliance and RoHS/REACH/EU declarations plus UL/CSA certification and multiple regional approvals. Business Impact Enables global deployments with minimal regulatory risk. Application Ideal for multinational plants requiring harmonized electrical protection and control.
Get a Quick Quote for a ABB 1SFL587063R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL587063R1322?
Enquire Now
FAQs
This 3P block contactor uses main circuit bars for terminals and supports pre-mounted auxiliary contacts with the option to add contact blocks. It fits standard panel mounting footprints and pairs with AF265–AF370 family accessories. For CAD and installation planning, refer to the Dimension Diagram and CAD Dimensional Drawing in the downloads to ensure proper clearances and wiring routes.
The device provides a 1000 V rated main circuit with AC‑3 current up to 290–305 A depending on voltage and temperature, and AC‑1 up to 375 A at 40 °C. Coil voltage range is 100–250 V (AC/DC). It also features built‑in surge protection and a mechanical durability of about 5 million cycles, with a maximum switching rate of 300 cycles per hour.
Yes. With 3 poles, 1000 V main circuit and high AC‑3 current ratings, it handles motors up to 160 kW at 400 V, 250 hp, in general use circuits. Its wide control voltage tolerance and auxiliary contacts support motor protection schemes, interlocking, and signaling for pumps, conveyors, and processing lines.
The contactor complies with IEC/EN 60947‑1 and 60947‑4‑1, UL 60947‑4‑1, CSA equivalents, CE and UKCA declarations, and EAC/UL certificates. It also carries RoHS and REACH declarations, CMRT, and WEEE classifications, enabling global deployment with minimized compliance risk.
The AF technology reduces energy consumption in control circuits, while built‑in surge protection lowers accessory costs. Long mechanical durability (up to 5 million cycles) and low coil consumption (VA ratings) translate to reduced maintenance and replacement cycles, delivering lower lifecycle costs in high‑duty industrial environments.