ABB AX300-30-11-81 Contactor is a high-capacity motor control device designed for heavy-duty switching in industrial power circuits. When downtime or wiring errors slow line starts, a robust, clearly specified contactor helps reduce maintenance and startup risk. It carries CE and UL certifications with IP40 auxiliary terminations and 690 V insulation, ensuring safe, compliant operation in demanding environments. This block contactor is ideal for motor protection and control in AC-3 switching scenarios, delivering reliable coil control at 24 V while supporting broader automation objectives and reduced lifecycle costs for your production line.

Product Information

Extended Description

1SFL587074R8111 ABB: AX300-30-11-81 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
1SFC101062M0201_E
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
4.7 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 500 A | (690 V) 55 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A | (440 V) 55 °C 305 A | (500 V) 55 °C 290 A | (690 V) 55 °C 290 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Power Loss
at Rated Operating Conditions per Pole 19 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
175 mm
Package Level 1 Depth / Length
270 mm
Package Level 1 Height
223 mm
Package Level 1 Gross Weight
5.4 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AX300-30-11-81 is a three-pole block contactor with three main NO contacts and one NO plus one NC auxiliary contact, enabling straightforward motor interlocking and signaling. This configuration reduces wiring complexity and improves diagnostic visibility during startup, delivering faster maintenance and improved uptime for conveyors and pumps. Feature → Business Impact → Application: Rated Insulation Voltage of 690 V and a broad voltage/frequency range supports standard European mains and diverse plant layouts, enabling a single part across multiple applications and reducing stocking costs. Feature → Business Impact → Application: A 24 V control coil (50 Hz/60 Hz) simplifies integration with existing PLCs and safety interlocks, lowering control room wiring and enabling quick retrofits in modernization projects. Feature → Business Impact → Application: High short-time withstand currents and robust AC-3 performance (up to 305 A at 55°C, 290–305 A across 380–690 V ranges) provide reliable motor starting and reduced contact wear in demanding loads. Feature → Business Impact → Application: Mechanical durability of 5 million cycles and 19 W per pole power loss translate to longer service life and cooler operation, lowering replace-and-dail maintenance costs in heavy-traffic equipment such as presses and extruders. Feature → Business Impact → Application: Dimensions of 140 x 180 x 225 mm and weight of 4.7 kg offer solid mounting stability in compact MCCs and control cabinets, with compatible main terminal bars for rugged connections. Feature → Business Impact → Application: IP40 protection for auxiliary terminals and available CAD drawings enable smoother installation and early-stage integration in design workflows, accelerating time-to-commission on high-volume lines. These capabilities address common objections about derating, installation space, and maintenance planning, while aligning with industry best practices for motor protection and control.

Get a Quick Quote for a ABB 1SFL587074R8111

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL587074R8111? Enquire Now

FAQs

The AX300-30-11-81 is a three-pole block contactor featuring 3 main NO contacts and 1 NO + 1 NC auxiliary contact. It uses main circuit bars for connections and has IP40 auxiliary terminals. Ensure supply voltage is within 690 V insulation rating, and use 24 V control coil with 50/60 Hz to match your PLC or control logic. Adequate space and ventilation minimize derating at higher ambient temperatures.
Rated Operational Current AC-3 at 415 V/55°C is 305 A, at 440 V/55°C 305 A, at 500 V/55°C 290 A, at 690 V/55°C 290 A, and at 380/400 V/55°C 305 A, with similar values at 220/230/240 V. At higher ambient temperatures the Ie values decrease: 55°C yields lower current capability than 40°C. For condensation and startup surges, refer to the 8 x Ie breaking capacity and 10 x Ie making capacity ratings.
Yes, the AX300-30-11-81 carries CE and UL certifications, withIEC/EN compliance for AC-3 contactors and RoHS/Reach declarations. It complies with WEEE B2B categorization and is listed for motor protection and control. An optional CCC declaration and CQC certificate indicate broader regional approvals. The device also features IP40 protection for auxiliary terminals and a 690 V insulation rating.
With a mechanical durability rated at 5 million cycles and a per-pole power loss of 19 W, the AX300-30-11-81 offers long service life with predictable thermal performance. Plan for periodic inspection of contacts and coil health, and ensure cooling is adequate in high-load cabinets to prevent derating. Replacement timing aligns with observed contact wear and insulation integrity in demanding environments.
The combination of high AC-3 current ratings, low power loss per pole, and robust electrical endurance reduces downtime and maintenance costs while supporting higher motor starting reliability. Universal coil voltage and wide insulation enable faster modernization with fewer parts, lowering spare part variety. Overall, expect improved line uptime and reduced energy waste in high-demand applications like conveyors, pumps, and extrusion lines.