ABB AX300-30-11-88 Contactor - CE/UL Certified
Part Number: 1SFL587074R8811
Quick Summary
ABB AX300-30-11-88 Contactor protects motors by switching high-power loads up to 1000 V. Designers and panel builders often wrestle with derating, space constraints, and wiring complexity in motor control applications. With CE, UL, and CCC certifications, plus IP40 protection for auxiliary terminals, this unit offers reliable compliance across global markets and safer operation. Its compact 3P block design and flexible control voltage options help reduce panel footprint while delivering robust performance in demanding industrial environments.
Product Information
Extended Description
1SFL587074R8811 ABB: AX300-30-11-88 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
1SFC101062M0201_E
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
4.7 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 500 A | (690 V) 55 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A | (440 V) 55 °C 305 A | (500 V) 55 °C 290 A | (690 V) 55 °C 290 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions per Pole 19 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
175 mm
Package Level 1 Depth / Length
270 mm
Package Level 1 Height
223 mm
Package Level 1 Gross Weight
5.4 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AX300-30-11-88 uses a 3P block contour with 3 NO main contacts and 1 NO/1 NC auxiliary contact, enabling efficient three-phase motor switching in a single device. This reduces panel wiring, speeds assembly, and lowers total cost of ownership for conveyors, pumps, and fans in automation lines. Application: ideal for machine control cabinets where space is at a premium and reliable motor start/stop is critical. Feature → Business Impact → Application: Rated operational voltage up to 1000 V and insulation voltage of 690 V support safe high-voltage switching across diverse plant architectures. This supports IEC 60947-4-1 compliant designs and expands compatibility with mixed-voltage panels. Application: suitable for high-power drives and mixed-voltage applications in steel, packaging, and process industries. Feature → Business Impact → Application: Mechanical durability rated at 5 million cycles and a maximum switching frequency of 300 cycles per hour translate to predictable lifecycle costs and reduced maintenance. Application: long-life performance in rolling mills, extruders, and material handling lines. Feature → Business Impact → Application: Rated AC-3 power handling up to 305 A at various voltages and I_e up to 500 A (AC-1) provides sizing headroom for motor starting torque and frequent switching. Application: supports motors with high inrush and demanding duty cycles in pumps and fans. Feature → Business Impact → Application: Control circuit options at 50 Hz 230–240 V or 60 Hz 240–260 V enable seamless integration with common facility power supplies. Application: simplifies panel design and reduces part count in global deployments. Feature → Business Impact → Application: Compact dimensions (140 mm W × 180 mm D × 225 mm H) and 4.7 kg weight reduce enclosure footprint and facilitate retrofits. Application: beneficial in retrofit projects and space-constrained control panels in manufacturing lines.
Get a Quick Quote for a ABB 1SFL587074R8811
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL587074R8811?
Enquire Now
FAQs
Installation starts with selecting the correct 3P panel location and ensuring adequate clearance for heat dissipation. Mount the unit so the main circuit terminals accept busbars and connect the auxiliary contact wiring per the wiring diagram. Verify coil voltage options (230–240V at 50 Hz or 240–260V at 60 Hz), tighten connections to spec, and test with a low-current pilot to confirm operation.
For AC-3 duty at 690V, the contactor provides up to 305 A rated operational current at 55°C, with a rated operational power up to 250 kW at 690V. It also supports 8 x Ie as rated breaking capacity and 10 x Ie for making capacity, ensuring strong performance for motor starting and shutdown under typical industrial loads.
Yes. The control circuit voltage is 50 Hz 230–240 V or 60 Hz 240–260 V, allowing seamless integration with common facility power supplies. When selecting a control source, ensure the coil voltage matches the 60 Hz specification to maintain reliable actuation and avoid nuisance tripping.
The AX300-30-11-88 carries CE and UL certifications, along with CCC/CQC for certain markets. It also aligns with RoHS requirements and has a WEEE-compliant designation for B2B usage. These certifications support global deployment and regulatory compliance in electrical panels and automation systems.
Auxiliary terminals are protected to IP40, which is suitable for control cabinet environments. The unit operates from -25 to 55°C with a thermal overload relay installed (or -40 to 70°C in other configurations) and up to an altitude of 3000 m without derating, making it robust for a wide range of industrial installations.