ABB 1SFL587102R1411 Contactor - UL Listed, 4P 1000V AF

Part Number: 1SFL587102R1411
Manufacturer
ABB
Part number
1SFL587102R1411

Quick Summary

The ABB 1SFL587102R1411 contactor is a four-pole motor-contactor for 160 kW motors at 400 V. In panel installations, voltage fluctuations and limited space can trigger nuisance trips and energy waste. This device carries CE and UL/CSA certifications with UKCA marking, plus RoHS compliance, supporting regional regulatory needs. AF technology delivers a wide control voltage range, enabling stable operation in unstable networks and helping reduce panel energy consumption. Its compact block design and compatibility with AF accessory blocks support scalable, energy-efficient motor control while simplifying installation and service life.

Product Information

Extended Description

1SFL587102R1411 ABB: The AF305-40-11-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 160 kW / 400 V AC (AC-3) / and switching power circuits up to 500 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF265,AF305,AF370
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225.4 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A | (1000 V) 60 °C 325 A | (1000 V) 70 °C 260 A | (690 V) 40 °C 500 A | (690 V) 60 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A | (440 V) 55 °C 305 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage DC 4.7 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 650 W
Power Loss
at Rated Operating Conditions per Pole 50 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Main Circuit
Flexible 1 x 16 ... 240 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 1 x 6 ... 300 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 28 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 400 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp | (200 V AC) Three Phase 100 hp | (208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 50 Hp | (220 ... 240 V AC) Three Phase 125 hp | (440 ... 480 V AC) Three Phase 100 Hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 150 Hp | (550 ... 600 V AC) Three Phase 300 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF265-40, AF305-40, AF370-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500504970
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707241
E-Number (Norway)
3210345
E-Number (Sweden)
3210345
The 1SFL587102R1411 employs a four-pole main circuit rated up to 1000 V, enabling control of motors up to 160 kW with a main current capacity of up to 375 A (AC-1) and 305 A (AC-3) at 415–440 V. This translates to robust performance in demanding industrial drives where reliability and uptime are critical; users benefit from reduced voltage drops and improved motor starting characteristics in variable supply environments. AF technology provides a wide control circuit voltage range (250–500 V for AC and DC operation), which minimizes control voltage sensitivity, lowers energy waste, and improves overall system efficiency in fluctuating networks. A built-in surge protection feature reduces the need for external protection modules, saving panel space and installation costs while increasing protection against transients. The device’s pre-mounted auxiliary contacts (1 NO, 1 NC) and main circuit bars simplify wiring and accelerate commissioning, while the block-type design supports easy expansion with add-on auxiliary contact blocks as control logic evolves. With a compact footprint (184 mm width, 180 mm depth, 225.4 mm height) and a weight of 5.7 kg, it fits tight control panels and compact drives without compromising performance. Compliance with CE, UL/CSA, and UKCA standards, along with RoHS and REACH declarations, ensures regulatory readiness across global installations and minimizes risk during audits. Industry professionals will appreciate the combination of high electrical ratings, modularity, and energy efficiency that reduces total cost of ownership over the product lifecycle.

Get a Quick Quote for a ABB 1SFL587102R1411

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL587102R1411? Enquire Now

FAQs

Install as a four-pole block contactor with pre-mounted main circuit bars. Use the 184 mm x 180 mm footprint and 225.4 mm height to plan panel space. Torque the main circuit connections to 22–43 N·m and secure coil terminals per IP20 protection requirements. Ensure compatible auxiliary contact blocks are added only as needed for control circuit logic.
At 415–440 V, the unit provides AC-3 rated current of 305 A and 55 °C ambient rating; at 60 °C 325 A and 70 °C 260 A. Rated power AC-3 is 160 kW for 415–440 V configurations. Short-circuit withstand and making/breaking capacities are designed for reliable motor starting with up to 160 kW loads and appropriate fusing per IEC/UL guidelines.
Yes. The AF block contactor design supports expansion with add-on auxiliary contact blocks and a wide range of accessories. It is built for easy integration with existing AF265–AF370 families, enabling scalable control schemes and simplified future upgrades without replacing the main unit.
This product carries CE and UL/CSA certifications with UKCA marking, plus RoHS and REACH declarations. CE/UL/CSA confirm conformity to regional electrical safety standards, while UKCA supports UK market requirements. RoHS/REACH ensure restricted substance compliance, helping you meet regulatory audits and maintain market access.
AF technology provides a wide control voltage range, reducing the need for multiple coil variants and stabilizing operation under voltage variation. Built‑in surge protection lowers external protection requirements, cutting panel hardware and installation time. Overall, this translates to lower life-cycle costs, improved uptime, and energy-efficient motor control across variable network conditions.