ABB AF305B-40-22RT-11 Contactor - 1000 V UL/CSA 400A
Part Number: 1SFL587262R1122
Quick Summary
AF305B-40-22RT-11 Contactor for four poles enables reliable motor control up to 160 kW at 400 V AC. In demanding panels, this solution helps manage wide voltage variations and keep systems running smoothly. CE, UL/CSA, and UKCA certifications support global compliance and safe operation across markets, while the inherent surge protection protects equipment from startup transients. The AF series also offers a compact block design, easy expansion with add-on auxiliary contacts, and energy-efficient coil performance, aligning with modern automation and sustainability goals.
Product Information
Extended Description
1SFL587262R1122 ABB: The AF305B-40-22RT-11 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 160 kW / 400 V AC (AC-3) / and switching power circuits up to 500 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A | (1000 V) 60 °C 325 A | (1000 V) 70 °C 260 A | (690 V) 40 °C 500 A | (690 V) 60 °C 400 A | (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A | (440 V) 55 °C 305 A | (380 / 400 V) 55 °C 305 A | (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 500 A | (100 V) 1 Pole, 60 °C 400 A | (100 V) 1 Pole, 70 °C 325 A | (110 V) 1-Pole, 40 °C 500 A | (110 V) 1-Pole, 60 °C 400 A | (110 V) 1-Pole, 70 °C 325 A | (110 V) 2 Poles in Series, 40 °C 500 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 500 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (175 V) 2 Poles in Series, 40 °C 500 A | (175 V) 2 Poles in Series, 60 °C 400 A | (175 V) 2 Poles in Series, 70 °C 325 A | (200 V) 2 Poles in Series, 40 °C 500 A | (200 V) 2 Poles in Series, 60 °C 400 A | (200 V) 2 Poles in Series, 70 °C 325 A | (220 V) 2 Poles in Series, 40 °C 500 A | (220 V) 2 Poles in Series, 60 °C 400 A | (220 V) 2 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 500 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (260 V) 3 Poles in Series, 40 °C 500 A | (260 V) 3 Poles in Series, 60 °C 400 A | (260 V) 3 Poles in Series, 70 °C 325 A | (300 V) 3 Poles in Series, 40 °C 500 A | (300 V) 3 Poles in Series, 60 °C 400 A | (300 V) 3 Poles in Series, 70 °C 325 A | (340 V) 3 Poles in Series, 40 °C 500 A | (340 V) 3 Poles in Series, 60 °C 400 A | (340 V) 3 Poles in Series, 70 °C 325 A | (350 V) 4 Poles in Series, 40 °C 500 A | (350 V) 4 Poles in Series, 60 °C 400 A | (350 V) 4 Poles in Series, 70 °C 325 A | (400 V) 4 Poles in Series, 40 °C 500 A | (400 V) 4 Poles in Series, 60 °C 400 A | (400 V) 4 Poles in Series, 70 °C 325 A | (440 V) 4 Poles in Series, 40 °C 500 A | (440 V) 4 Poles in Series, 60 °C 400 A | (440 V) 4 Poles in Series, 70 °C 325 A | (72 V) 1-Pole, 40 °C 500 A | (72 V) 1-Pole, 60 °C 400 A | (72 V) 1-Pole, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 500 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 500 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A | (90 V) 1 Pole, 40 °C 500 A | (90 V) 1 Pole, 60 °C 400 A | (90 V) 1 Pole, 70 °C 325 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A | (110 V) 2 Poles in Series, 60 °C 400 A | (110 V) 2 Poles in Series, 70 °C 325 A | (110 V) 3 Poles in Series, 40 °C 400 A | (110 V) 3 Poles in Series, 60 °C 400 A | (110 V) 3 Poles in Series, 70 °C 325 A | (220 V) 3 Poles in Series, 40 °C 400 A | (220 V) 3 Poles in Series, 60 °C 400 A | (220 V) 3 Poles in Series, 70 °C 325 A | (72 V) 2 Poles in Series, 40 °C 400 A | (72 V) 2 Poles in Series, 60 °C 400 A | (72 V) 2 Poles in Series, 70 °C 325 A | (72 V) 3 Poles in Series, 40 °C 400 A | (72 V) 3 Poles in Series, 60 °C 400 A | (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW | (440 V) 160 kW | (500 V) 200 kW | (690 V) 250 kW | (1000 V) 185 kW | (380 / 400 V) 160 kW | (220 / 230 / 240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
50 W | at Rated Operating Conditions per Pole 50 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 400 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp | (200 V AC) Three Phase 100 hp | (208 V AC) Three Phase 100 hp | (220 ... 240 V AC) Three Phase 50 Hp | (220 ... 240 V AC) Three Phase 125 hp | (440 ... 480 V AC) Three Phase 100 Hp | (440 ... 480 V AC) Three Phase 250 hp | (550 ... 600 V AC) Three Phase 150 Hp | (550 ... 600 V AC) Three Phase 300 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF265B..RT - AF370B-40...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF265B..RT - AF370B-40...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500509753
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four-pole, block-design contactor with pre-mounted auxiliary contacts. Business Impact: Reduces panel wiring, saves space, and simplifies installation while delivering robust motor control. Application: Ideal for conveyors, pumps, and machine tools where reliable starting is essential. Feature: Wide control voltage range 24-60 VAC / 20-60 VDC. Business Impact: Stabilizes operation amid voltage fluctuations, minimizes nuisance tripping, and lowers energy waste in unstable networks. Application: Suitable for systems with varying control signals or long wiring runs. Feature: Built-in surge protection. Business Impact: Extends life of the coil and downstream electronics, reducing maintenance and replacement costs. Application: Start-stop-heavy applications with high inrush. Feature: High rated currents and power capability (AC-3 up to 305 A; motors up to 160 kW at 400 V). Business Impact: Supports large motors and heavy loads, enabling fewer devices in a system and streamlined spare parts. Application: Heavy-duty drives and process equipment. Feature: 5 million mechanical cycles and 300 cycles per hour switching. Business Impact: Demonstrates durability and predictable lifecycle, lowering downtime risk and maintenance frequency. Application: High-usage manufacturing lines and continuous-process equipment. Feature: Compatibility with add-on auxiliary contact blocks. Business Impact: Flexible signaling and control expansion without redesign, reducing retrofit costs. Application: Customized control schemes and diagnostics for complex machinery. Feature: Certified and compliant (CE, UL/CSA, UKCA). Business Impact: Supports global procurement and regulatory adherence, minimizing risk in multinational projects. Application: Global plant rollout and cross-border supply chains.
Get a Quick Quote for a ABB 1SFL587262R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL587262R1122?
Enquire Now
FAQs
The AF305B-40-22RT-11 is rated for a main circuit up to 1000 V and supports AC-3 ratings around 305 A at typical industrial voltages (e.g., 415–440 V). It is suitable for motor control up to about 160 kW at 400 V AC, making it a strong fit for high-power drives and purpose-built motor starters.
Its coil tolerances cover 24–60 VAC and 20–60 VDC, which stabilizes performance amid voltage fluctuations and sensor noise. This reduces false trips, lowers energy waste, and simplifies wiring when sources are variable or long cable runs are involved.
The AF305B-40-22RT-11 carries CE and UL/CSA markings, with UKCA recognition as part of ABB’s global compliance portfolio. This helps streamline cross-border sourcing and ensures alignment with essential safety and performance standards.
Yes. The AF series is designed for easy extension with add-on auxiliary contact blocks, enabling scalable signaling and control options without replacing the base device.
Typical applications include motor starters for conveyors, pumps, and processing lines where reliable switching is critical. With a rated mechanical durability of about 5 million cycles and built-in surge protection, maintenance intervals can be extended, reducing downtime and total cost of ownership.