ABB 1SFL597001N6911 Block Contactor - UL/IEC 1000V

Part Number: 1SFL597001N6911
Manufacturer
ABB
Part number
1SFL597001N6911

Quick Summary

Block Contactor 1SFL597001N6911 provides reliable motor control for large AC motors in manufacturing lines. Engineers often face voltage fluctuations and energy waste in control panels, which this device helps mitigate with a wide control voltage range (48–130 V) and a compact AF technology design. It complies with IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, plus UL 508 and CSA C22.2 N°14, delivering CE conformity for global deployments. The combination of built-in surge protection and modular add-on auxiliary contacts offers flexible installation, quick commissioning, and improved reliability in demanding industrial environments, supporting energy efficiency and lower lifecycle costs for panel builders and end users alike.

Product Information

Extended Description

1SFL597001N6911 ABB: The AF460N6-30-11-69 NEMA Contactor is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit: Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V, 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 700 A | (1000 V) 55 °C 600 A | (1000 V) 60 °C 600 A | (1000 V) 70 °C 480 A | (690 V) 40 °C 700 A | (690 V) 55 °C 600 A | (690 V) 70 °C 480 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 460 A | (440 V) 55 °C 460 A | (500 V) 55 °C 460 A | (690 V) 55 °C 400 A | (1000 V) 55 °C 200 A | (380 / 400 V) 55 °C 460 A | (220 / 230 / 240 V) 55 °C 460 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Power AC-3 (Pe)
(415 V) 250 kW | (440 V) 250 kW | (500 V) 315 kW | (690 V) 355 kW | (1000 V) 280 kW | (380 / 400 V) 250 kW | (220 / 230 / 240 V) 132 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 1.5 ... 1.8 In A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1215 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1215 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 1150 V·A
Power Loss
at Rated Operating Conditions per Pole 21 W
Operate Time
Between Coil De-energization and NC Contact Closing 45 ... 55 ms | Between Coil De-energization and NO Contact Opening 48 ... 58 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 47 mm² | Rigid Al-Cable 2x240 mm² | Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm²
Connecting Capacity
Rigid Al-Cable 2x240 mm² | Rigid Cu-Cable 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 35 N·m | Main Circuit 35 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
6
Horsepower Rating NEMA
(200 V AC) Three Phase 150 Hp | (230 V AC) Three Phase 200 Hp | (460 V AC) Three Phase 400 Hp | (575 V AC) Three Phase 400 Hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)400(B)-**;AF(S)460(B)-**;AF460N6
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
CB Certificate
SE-82316
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Package Level 1 EAN
7320500543658
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4762 >> Nema Contactors
Feature → Business Impact → Application: AF technology enables a broad control voltage range (48–130 V) with stable operation across fluctuating power networks, reducing panel energy waste and extending motor life in variable supply environments. Application: motor control in conveyors and pumps where supply quality may vary. Feature → Business Impact → Application: 3-pole main contacts plus 1 NO and 1 NC auxiliary contact block delivers straightforward signaling and protection, simplifying control logic and enabling precise motor start/stop sequences. Application: automated line start-up sequences in packaging or processing lines. Feature → Business Impact → Application: rated main circuit up to 1000 V and AC-3 currents up to 460–700 A across temperature ranges ensures high-power motors can be controlled safely with predictable performance. Application: large motor starters in HVAC, conveyors, and pumps. Feature → Business Impact → Application: built‑in surge protection and compatibility with add‑on auxiliary contact blocks reduce panel size and wiring complexity, accelerating installation and maintenance. Application: retrofit projects and new builds requiring compact, reliable control gear. Feature → Business Impact → Application: wide operating temperature and altitude tolerance (−25 to 70 °C; up to 3000 m) supports installations in harsh environments, lowering derating concerns. Application: outdoor or industrial environments with temperature swings. Feature → Business Impact → Application: IP20 coil terminals and IP00 main terminals along with defined tightening torques (35 N·m) simplify wiring and ensure robust connections, reducing field faults. Application: panel assembly and cabinet wiring in demanding production lines.

Get a Quick Quote for a ABB 1SFL597001N6911

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL597001N6911? Enquire Now

FAQs

The main circuit is rated up to 1000 V with AC-3 operation, and it supports currents up to 700 A depending on voltage and ambient temperature (e.g., 460 A at 415 V, 460 A at 440–690 V, and 200 A at 1000 V for AC-3). It operates at 50/60 Hz, with DC options available for coil drive within 48–130 V.
It is a 3-pole contactor with 3 main NO contacts, 0 NC contacts, and 1 NO plus 1 NC auxiliary contact block for signaling and control.
The coil supports 48–130 V for 50 Hz, 60 Hz, and DC operation, enabling compatibility with varying control circuits and logic levels.
Yes, the unit has built-in surge protection. It is designed to be extended with add-on auxiliary contact blocks and a broad range of accessories for flexible installation.
It adheres to IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14, and carries a CE declaration of conformity, with RoHS and related environmental declarations available.