ABB 1SFL597001R6900 Block Contactor - 1000V Main Circuit

Part Number: 1SFL597001R6900
Manufacturer
ABB
Part number
1SFL597001R6900

Quick Summary

Block Contactor ABB 1SFL597001R6900 for motor control in industrial automation environments. Engineers often face voltage swings and energy waste in panels operating on unstable networks, making reliable switching essential. This device adheres to CE, UL/CSA, and UKCA requirements, providing confidence across EU, US, and UK markets while offering surge protection and AF technology. With a modular block design and compatibility for add-on auxiliary contact blocks, it delivers practical value, scalable installation, and measurable energy efficiency in demanding applications.

Product Information

Extended Description

1SFL597001R6900 ABB: The AF460-30-00-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 700 A | (1000 V) 60 °C 600 A | (1000 V) 70 °C 480 A | (690 V) 40 °C 700 A | (690 V) 70 °C 480 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 460 A | (440 V) 55 °C 460 A | (500 V) 55 °C 460 A | (690 V) 55 °C 400 A | (1000 V) 55 °C 200 A | (380 / 400 V) 55 °C 460 A | (220 / 230 / 240 V) 55 °C 460 A
Rated Operational Power AC-3 (Pe)
(415 V) 250 kW | (440 V) 250 kW | (500 V) 315 kW | (690 V) 355 kW | (1000 V) 280 kW | (380 / 400 V) 250 kW | (220 / 230 / 240 V) 132 kW
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Mechanical Durability
3 million
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1215 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1215 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 1150 V·A
Power Loss
at Rated Operating Conditions per Pole 21 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
6
Horsepower Rating NEMA
(200 V AC) Three Phase 150 Hp | (230 V AC) Three Phase 200 Hp | (460 V AC) Three Phase 400 Hp | (575 V AC) Three Phase 400 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 650 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 150 Hp | (220 ... 240 V AC) Three Phase 200 Hp | (440 ... 480 V AC) Three Phase 400 Hp | (550 ... 600 V AC) Three Phase 500 Hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)400(B)-**;AF(S)460(B)-**;AF460N6
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82316
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF400, AF460, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF400, AF460, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF400, AF460, AFS400, AFS460
UL Listing Card
UL_E36588
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3-pole main circuit, rated for up to 1000 V, enables reliable motor switching in high-voltage systems, delivering dependable performance for industrial drives and equipment. This translates to reduced downtime and smoother startup sequences in manufacturing lines, particularly for AC-3 applications up to 460 A at common voltages. Feature → Business Impact → Application: Coil voltage range 48–130 V (AC) and DC allows a wide control voltage tolerance, minimizing control circuit failures and panel power waste in plants with fluctuating supplies. This is ideal for retrofits or installations with mixed supply environments where maintaining consistent coil energization is critical. Feature → Business Impact → Application: Built-in surge protection protects contacts from voltage spikes during motor start-up and grid disturbances, extending life and reducing maintenance costs in heavy-demand environments. Feature → Business Impact → Application: AF technology provides a wide control voltage range and energy efficiency benefits, leading to lower panel heat and energy consumption on long-running conveyors and pumps. Feature → Business Impact → Application: Modular, block-type design supports easy expansion with auxiliary contact blocks and accessories, enabling scalable control circuits for growing automation needs. Feature → Business Impact → Application: Mechanical durability of 3 million cycles offers long service life in high-cycle applications, reducing replacement intervals and total cost of ownership for OEMs and end users. Feature → Business Impact → Application: Terminal type is main circuit bars, simplifying wiring and improving reliability in dense control panels.

Get a Quick Quote for a ABB 1SFL597001R6900

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL597001R6900? Enquire Now

FAQs

The device uses a block-type design with main circuit bars for straightforward wiring and a modular approach. Ensure the panel supports 1000 V insulation voltage and that the coil control circuit matches 48–130 V AC or DC. Extend the control circuit with add-on auxiliary contact blocks as needed to match your automation logic and IO requirements.
Key ratings include AC-3 currents up to 460 A at 690 V (and various voltage configurations), AC-1 ratings up to 700 A at 1000 V, and a corresponding AC-3 power handling up to about 355 kW at 690 V. The unit is designed for three poles and main circuit voltage up to 1000 V with 48–130 V coil control signals.
Yes. With a mechanical durability rating of 3 million cycles and a modular design that supports accessories, it is well-suited for high-cycle motor starters and variable-speed drives, reducing replacement intervals and maintenance costs in production lines.
The product carries CE and UL/CSA listings, UKCA marking, and RoHS/REACH declarations, plus associated DoCs. This combination supports regulatory compliance for EU, UK, and US markets, simplifying cross-border procurement and documentation.
Built-in surge protection shields contacts from voltage spikes, reducing contact wear and arcing. This translates to longer maintenance intervals, lower failure rates, and improved reliability for critical loads in plants with unstable supply or frequent switching events.