ABB AF460-30-11 Block Contactor - 1000 V Main Circuit

Part Number: 1SFL597001R7011
Manufacturer
ABB
Part number
1SFL597001R7011

Quick Summary

ABB AF460-30-11 Block Contactor is a high-capacity three-pole starter designed for 100-250 V control and a 1000 V main circuit. In panel installations, voltage variation on the control side can cause nuisance trips and inconsistent motor startup; this AF technology-based device tolerates wide control voltage ranges to stabilize operation. The unit ships with pre-mounted auxiliary contacts and main circuit bars, and it’s rated for AC-3 duty up to 200 A at 690–1000 V depending on voltage. CE and UL/CSA certifications, plus IP20 coil protection, support global compliance and safe panel integration. For engineers and procurement teams, these features translate to faster commissioning, reduced wiring, and lower lifecycle costs in fluctuating power environments.

Product Information

Extended Description

1SFL597001R7011 ABB: The AF460-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Country of Origin
India (IN)
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABB010EXPU
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-59
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 700 A | (1000 V) 55 °C 600 A | (1000 V) 60 °C 600 A | (1000 V) 70 °C 480 A | (690 V) 40 °C 700 A | (690 V) 55 °C 600 A | (690 V) 70 °C 480 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 460 A | (440 V) 55 °C 460 A | (500 V) 55 °C 460 A | (690 V) 55 °C 400 A | (1000 V) 55 °C 200 A | (380 / 400 V) 55 °C 460 A | (220 / 230 / 240 V) 55 °C 460 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 700 A | (110 V) 2 Poles in Series, 40 °C 700 A | (220 V) 3 Poles in Series, 40 °C 700 A | (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Power AC-3 (Pe)
(415 V) 250 kW | (440 V) 250 kW | (500 V) 315 kW | (690 V) 355 kW | (1000 V) 280 kW | (380 / 400 V) 250 kW | (220 / 230 / 240 V) 132 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 1.5 ... 1.8 In A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 955 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 955 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 895 V·A
Power Loss
at Rated Operating Conditions per Pole 21 W
Operate Time
Between Coil De-energization and NC Contact Closing 45 ... 55 ms | Between Coil De-energization and NO Contact Opening 48 ... 58 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 47 mm² | Rigid Al-Cable 2x240 mm² | Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 47 mm² | Rigid Al-Cable 2x240 mm² | Rigid Cu-Cable 240 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 35 N·m | Main Circuit 35 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
6
Horsepower Rating NEMA
(200 V AC) Three Phase 150 Hp | (230 V AC) Three Phase 200 Hp | (460 V AC) Three Phase 400 Hp | (575 V AC) Three Phase 400 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 650 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 150 hp | (208 V AC) Three Phase 150 hp | (220 ... 240 V AC) Three Phase 200 hp | (440 ... 480 V AC) Three Phase 400 hp | (550 ... 600 V AC) Three Phase 500 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 477 A | (550 ... 600 V AC) Three Phase 472 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)400(B)-**;AF(S)460(B)-**;AF460N6
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82316
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF400, AF460, Made in China
CSA Certificate
306711
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF400-30-*-*,AF460-30-*-*,AFS400-30-*-*, AFS460-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF400, AF460, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV_E-10966
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_42988-02HH
LOVAG Certificate
FI102
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF400, AF460, AFS400, AFS460
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Package Level 1 EAN
7320500217658
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3709333
E-Number (Norway)
4115292
E-Number (Sweden)
3228346
AF technology delivers a wide control voltage range (100-250 V AC/DC), enabling stable operation in networks with voltage fluctuations and reducing panel energy consumption. Business impact: fewer mis-trips and less downtime; application: automation panels in variable supply factories. The three-pole main contacts with one NO auxiliary and one NC auxiliary support straightforward motor control and fault monitoring, allowing downstream equipment to respond quickly to control signals. Business impact: improved motor start/stop performance; application: HVAC, conveyors, and pumps. Built-in surge protection shortens misoperation risk in harsh electrical environments, reducing service calls and warranty claims. Business impact: lower maintenance costs; application: heavy-duty machine controls in manufacturing lines. The block-type design is easily extended with add-on auxiliary contact blocks, enabling scalable control logic without re-wiring. Business impact: future-proofing and modular upgrades; application: evolving automation architectures. The device’s rated insulation and current handling (AC-3 up to 460 A at typical voltages) support high-power applications with compact footprint. Business impact: denser panels and lower enclosure costs; application: large motors and process lines. Its compatibility with standard connecting capacities (main circuit bars, rigid Al/Cu cables) and IP20 coil protection simplifies installation and protects control circuitry. Business impact: faster commissioning and reliable long-term operation; application: OEM and panel builder environments.

Get a Quick Quote for a ABB 1SFL597001R7011

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL597001R7011? Enquire Now

FAQs

The AF460-30-11 uses a block contactor design with pre-mounted auxiliary NO/NC contacts and standard main terminals. It accepts main circuit connections via bars or rigid cables up to 240 mm² for high-current applications and matches common DIN-rail or panel layouts. This facilitates straightforward wiring, reduces installation time, and ensures reliable control signaling for motor starters in automation panels.
For AC-3 duty, the contactor supports up to 460 A at 415 V and 460 A at 440-460 V variants, with reduced ratings at higher ambient temperatures. AC-1 ratings reach up to 700 A at 1000 V and up to 700 A at 690 V under specified conditions. These figures make the AF460-30-11 suitable for high-inertia motors and demanding start-stop cycles typical in industrial drives.
Yes. The AF460-30-11 is designed for 1000 V main circuits and 100-250 V control voltage, including DC operation within the specified range. Its three-pole configuration, built-in surge protection, and auxiliary contact blocks make it well-suited for HVAC compressors, pumps, and other equipment where stable, high-current switching is required under varying supply conditions.
The device carries CE and UL/CSA certifications, with additional UKCA marking and RoHS/REACH declarations. It also features IP20 coil protection and a range of safety and environmental declarations, including WEEE considerations. These certifications facilitate global deployment across Europe, North America, and other regions with robust regulatory requirements.
Expect low maintenance due to solid-state coil technology and robust mechanical durability (millions of mechanical cycles). Regular inspection of terminal connections and ensuring torque to spec prevents overheating. The built-in surge protection and modular accessory options reduce downtime and warranty-related service calls, delivering predictable lifecycle costs in high-demand, automation-intensive environments.