ABB 1SFL597001R9103 Block Contactor - UL/CSA, 1000V

Part Number: 1SFL597001R9103
Manufacturer
ABB
Part number
1SFL597001R9103

Quick Summary

AF460F-30-11 block contactor provides reliable motor control for fire pumps and industrial drives. Inconsistent control voltages and fluctuating networks often cause nuisance trips and energy waste in modern panels; this device mitigates those issues with a wide control voltage range and built-in surge protection. It carries CE and UKCA conformity, plus UL listings for global use, alongside RoHS and REACH declarations for responsible sourcing. Designed with AF technology, the contactor delivers improved energy efficiency and extended service life. Its block-type design supports easy expansion with add-on auxiliary contact blocks, reducing panel complexity and total cost of ownership in automation projects.

Product Information

Extended Description

1SFL597001R9103 ABB: The AF460F-30-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, for Fire Pump applications, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to n.a. A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (220-240 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
Instructions and Manuals (Part 2)
FirePump Contactors AF400F, AF460F, AF580F, AF750F
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 700 A | (1000 V) 60 °C 600 A | (1000 V) 70 °C 480 A | (690 V) 40 °C 700 A | (690 V) 70 °C 480 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 460 A | (440 V) 55 °C 460 A | (500 V) 55 °C 460 A | (690 V) 55 °C 400 A | (1000 V) 55 °C 200 A | (380 / 400 V) 55 °C 460 A | (220 / 230 / 240 V) 55 °C 460 A
Rated Operational Power AC-3 (Pe)
(415 V) 250 kW | (440 V) 250 kW | (500 V) 315 kW | (690 V) 355 kW | (1000 V) 280 kW | (380 / 400 V) 250 kW | (220 / 230 / 240 V) 132 kW
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Mechanical Durability
3 million
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V
Power Loss
at Rated Operating Conditions per Pole 21 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 650 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 150 hp | (208 V AC) Three Phase 150 hp | (220 ... 240 V AC) Three Phase 200 hp | (440 ... 480 V AC) Three Phase 400 hp | (550 ... 600 V AC) Three Phase 500 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 477 A | (550 ... 600 V AC) Three Phase 472 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)400(B)-**;AF(S)460(B)-**;AF460N6
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE)
CB Certificate
SE-82316
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
PRS Certificate
PRS Certificate - AF116...AF1650
UL Certificate
cULus Certificate, Contactor, AF400, AF460, AFS400, AFS460
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Package Level 1 EAN
7320500223185
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
3-pole AF460F-30-11 delivers three main normally open contacts with a robust 1000 V insulation rating, supporting AC-3 duty up to 460 A and up to 250 kW at 415 V. This enables compact, high-current motor starting with minimal voltage drop, making it ideal for fire pumps and large fans in demanding facilities. Wide control voltage range of 250-500 V AC/DC ensures stable operation despite network fluctuations, reducing false trips and energy waste in panel builds. It includes pre-mounted auxiliary contacts and the option to extend with auxiliary blocks, simplifying wiring and enabling scalable control signals, which lowers installation time and wiring errors in automation projects. Main Circuit Bars plus a block-type design offer a compact footprint and easy integration into switchgear, even in space-constrained installations, while delivering long service life with up to 3 million mechanical cycles. Compliance and safety are reinforced by CE, UKCA and UL certifications, with RoHS and REACH declarations supporting regional procurement, regulatory approval, and sustainability goals.

Get a Quick Quote for a ABB 1SFL597001R9103

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL597001R9103? Enquire Now

FAQs

ABB AF460F-30-11 is a 3-pole block contactor designed for direct integration into 3-phase power circuits. It uses main circuit bars for the primary connections, with a documented footprint of 186 mm wide, 216 mm deep, and 278 mm high, and a net weight of 10.6 kg. It ships with a pre-mounted auxiliary contact and supports expansion with add-on blocks, which simplifies wiring, reduces panel depth, and speeds up panel assembly during installation.
For AC-3 duty, the contactor supports up to 460 A at multiple voltages (e.g., 415 V and 690 V), enabling motor starts for power ranges up to roughly 250 kW at 415 V and substantial HP ratings at higher voltages (up to 400 hp at 440–480 V or 500 hp at 550–600 V in UL/CSA listings). This makes it suitable for demanding motors in HVAC, pumps, and process applications.
Yes. The AF460F-30-11 is specified with an AF technology platform and auxiliary contacts designed for fire pump control, offering reliable switching with surge protection and a wide control voltage range. Its robust insulation, 3P configuration, and 1000 V rating ensure dependable operation in critical fire protection circuits and associated emergency power systems.
The device carries CE Declaration of Conformity, UKCA labeling, and UL/cUL listings, along with RoHS II and REACH declarations. These certifications support regulatory approvals across Europe, the UK, and North American markets, reducing compliance risk in procurement and integration projects while ensuring alignment with environmental and safety standards.
With a mechanical durability rating of up to 3 million cycles and built-in surge protection, the AF460F-30-11 offers long service life and reduced maintenance intervals. Energy efficiency is enhanced by AF technology and the broad control voltage tolerance, contributing to lower energy consumption in variable networks. The compact footprint and extensible auxiliary functionality also lower total cost of ownership by simplifying wiring, spare parts, and future upgrades.