ABB 1SFL607002R1200 Block Contactor - UL/CSA 1000V
Part Number: 1SFL607002R1200
Quick Summary
The 1SFL607002R1200 block contactor enables reliable motor switching in 3‑pole, high‑voltage drives for industrial lines. In networks with voltage fluctuations or energy-hungry loads, unpredictable tripping and wasted energy threaten uptime. This device carries CE and UL/CSA certifications and IP20/IP00 protection, supporting global compliance and safe operation. Coupled with a wide control voltage range and compact block design, it delivers measurable business value in automation projects. Its AF technology tolerates control voltage variations from 48 to 130 V and supports DC operation, reducing panel energy consumption. The 3‑pole 1000 V main circuit and built‑in surge protection enable reliable motor control in demanding environments across global markets.
Product Information
Extended Description
1SFL607002R1200 ABB: The AF370-30-00-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 300 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 520 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF265, AF305,AF370
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 55 °C 350 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 600 A | (690 V) 55 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A | (440 V) 55 °C 370 A | (500 V) 55 °C 350 A | (690 V) 55 °C 315 A | (1000 V) 55 °C 141 A | (380 / 400 V) 55 °C 370 A | (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 360 W
Power Loss
at Rated Operating Conditions per Pole 27 W
Operate Time
Between Coil De-energization and NO Contact Opening 37 ... 47 ms | Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Flexible 1 x 16 ... 240 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 1 x 6 ... 300 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 28 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 125 hp | (208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 350 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 361 A | (550 ... 600 V AC) Three Phase 336 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE) | Environmental product declaration, AF265, AF305, AF370 (CN) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SE-89316
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden | CQC Certificate, Contactor, AF265, AF305, AF370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF265, AF305, AF370, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
EAC Certificate
9AKK107046A8618
GL Certificate
GL_95073-14HH
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500481851
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706494
E-Number (Norway)
3210166
Wide coil control range with AF technology enables operation from 48 to 130 V AC/DC, absorbing control-voltage swings. This improves reliability in unstable networks and lowers energy waste by avoiding unnecessary coil energization. Application: motor starters and drives in packaging lines and automated assembly systems. Built-in surge protection and a compact block design reduce panel footprint and wiring complexity. Business impact: protects circuits, extends service life, and simplifies installation in tight control panels. Application: OEMs and panel builders integrating AF technology contactors. Three main contacts configured for AC-3 duty at up to 1000 V main circuit. This supports motors up to 200 kW at 400–690 V, providing high starting torque and reliable switching for heavy loads. Application: conveyors, stamping presses, and process lines. Flexible connecting capacity in Main Circuit and a robust mechanical design simplify field wiring and serviceability. Application: retrofit projects and new builds with mixed conductor sizes. Compliance, environmental responsibility, and lifecycle considerations are integrated to support corporate sustainability goals—CE, UL/CSA, RoHS, and energy‑efficient operation. Application: OEMs pursuing eco‑solutions and end‑of‑life planning. Expandability and accessory options maintain future readiness; the block‑type design accepts add‑on auxiliary contact blocks for scalable automation.
Get a Quick Quote for a ABB 1SFL607002R1200
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607002R1200?
Enquire Now
FAQs
The coil operates within 50 Hz 48–130 V, 60 Hz 48–130 V, and DC 48–130 V, providing a wide range to accommodate voltage fluctuations and alternative control sources.
The main circuit is rated at 1000 V. Operational currents for AC-3 are 370 A at several voltages (e.g., 440–690 V) and 141 A at 1000 V, with higher AC-1 ratings (up to 600 A at 690 V). Always refer to the exact voltage/current table for application conditions.
Yes. It supports motors up to 200 kW in AC-3 service at 1000 V and offers built‑in surge protection. It also features 8 kV rated impulse withstand voltage and a 3-pole 1000 V main circuit for demanding industrial applications.
It carries CE and UL/CSA certifications, with IP20 protection for coil terminals and IP00 for main terminals, supporting global compliance and safe operation across environments.
The block design is compact and compatible with add-on auxiliary contact blocks, allowing scalable automation. It supports flexible main-circuit connections (2 x 70–185 mm² flexible, 185–240 mm² rigid) and standard wiring practices, reducing installation time and enabling easy upgrades.