ABB 1SFL607002R1311 Contactor - 1000V IEC/UL 600V
Part Number: 1SFL607002R1311
Quick Summary
ABB AF370 Contactor is a 3-pole motor starter designed for reliable panel motor control in industrial automation. Engineers often face control-voltage variability and energy waste in legacy starters, which can lead to increased downtime and maintenance costs. This AF370 family delivers robust performance with built-in surge protection and a wide control voltage range to accommodate variations in supply, reducing panel energy consumption and improving reliability. CE and UL/CSA certifications, IP ratings on coil terminals, and UKCA/CCC declarations ensure compliance across global installations. With AF technology, users gain streamlined maintenance, easy accessory expansion, and scalable installation for evolving control needs, delivering tangible efficiency and total-cost-of-ownership benefits.
Product Information
Extended Description
1SFL607002R1311 ABB: The AF370-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 300 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 520 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF265, AF305,AF370
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 55 °C 350 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 600 A | (690 V) 55 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A | (440 V) 55 °C 370 A | (500 V) 55 °C 350 A | (690 V) 55 °C 315 A | (1000 V) 55 °C 141 A | (380 / 400 V) 55 °C 370 A | (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A | Holding at Max. Rated Control Circuit Voltage DC 4.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Power Loss
at Rated Operating Conditions per Pole 27 W
Operate Time
Between Coil De-energization and NO Contact Opening 37 ... 47 ms | Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 28 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 125 hp | (208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 350 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 361 A | (550 ... 600 V AC) Three Phase 336 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE) | Environmental product declaration, AF265, AF305, AF370 (CN) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SE-89316
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden | CQC Certificate, Contactor, AF265, AF305, AF370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF265, AF305, AF370, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
EAC Certificate
9AKK107046A8618
GL Certificate
GL_95073-14HH
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500481899
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706498
E-Number (Norway)
4117655
E-Number (Sweden)
3210171
The AF370-30-11-13 Contactor integrates AF technology, delivering a wide control voltage range of 100-250 V AC, 50/60 Hz and DC operation to tolerate voltage fluctuations in imperfect power networks. This translates to fewer nuisance trips, smoother motor start-ups, and lower panel energy consumption—benefits essential for automated manufacturing lines and packaging facilities. Its 3-pole main circuit with 1000 V insulation and 600 A breaking capacity under open-contactor conditions provides a reliable core switching platform for motors up to 200 kW at 400 V AC (AC-3), reducing downtime and extending motor life in demanding environments. Pre-mounted auxiliary contacts (NO/NC) and a block-type design allow quick addition of auxiliary blocks or accessories, enabling seamless expansion as control logic evolves. The device’s rigid electrical connections (bars) and flexible conductor ranges support fast, secure installation in control cabinets, minimizing commissioning time. The built-in surge protection mitigates transients common in heavy industry, protecting downstream electronics and improving overall system reliability. With a rated insulation voltage of 1000 V and comprehensive conformity documents, it’s well-suited for global electrical standards and multi-region projects. This combination of power, protection, and modularity makes it an ideal choice for OEMs and panel builders aiming for consistent performance, reduced maintenance, and compliant, future-proof installations.
Get a Quick Quote for a ABB 1SFL607002R1311
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607002R1311?
Enquire Now
FAQs
The AF370-30-11-13 uses a block-type design with main circuit bars and pre-mounted auxiliary contacts, allowing straightforward bolt-on expansion with add-on auxiliary contact blocks. Connecting capacities support flexible 2 x 70 … 185 mm² flexible main cable and 2 x 0.75 … 2.5 mm² for auxiliaries. Coils accept 100-250 V AC/DC, enabling use across varied control circuits. Ensure panel space accommodates dimensions (approx. 140 mm wide, 180 mm deep, 225 mm high) and observe IP20 coil terminal protection and IP00 main terminal protection.
For AC-3 duty, the contactor provides 315–370 A depending on voltage and ambient temperature (e.g., 370 A at 415–440 V, 55 °C; 315 A at higher voltage ranges such as 690 V). It can switch up to 200 kW at rated AC-3 conditions (e.g., 200 kW at 380/400/415/440/690 V). The device supports a short-circuit protective device rating of gG type fuses up to 630 A and a rated breaking capacity of up to 4000–5000 A depending on voltage and cos φ conditions.
Yes. The coil control voltage range is 100–250 V for both 50 Hz and 60 Hz, with DC operation options, enabling operation across variable supply conditions. The AF technology helps tolerate large control voltage variations, reducing energy waste and ensuring reliable operation even in networks with voltage fluctuations. The unit also supports added accessories for expanded functionality as system needs evolve.
This product features CE Declaration of Conformity and UL/CSA readiness, with UKCA and other regional declarations available. It has IP20 protection on coilTerminals and IP00 on main terminals, meeting common safety standards for panel-mounted contactors. The device also carries RoHS, REACH, and other environmental declarations, supporting compliance in multi-region deployments.
Key ROI drivers include reduced energy consumption due to AF control technology and a robust design with surge protection that minimizes nuisance trips. The ability to pre-mount auxiliary contacts and extend with add-on blocks reduces panel rework during upgrades. High mechanical durability (up to 5 million cycles) and built-in protection support longer service life, lower maintenance costs, and predictable lifecycle costs for motor control applications.