ABB 1SFL607002R3100 Block Contactor - UL/CSA 1000 V

Part Number: 1SFL607002R3100
Manufacturer
ABB
Part number
1SFL607002R3100

Quick Summary

ABB AF contactor 1SFL607002R3100 is a three-pole motor control switch for industrial drives. In mixed-panel environments it delivers reliable switching across wide voltage variations, reducing panel energy waste and improving start-up stability. This interface supports CE, UKCA and UL/CSA certifications, along with RoHS compliance, which helps your global operations meet regulatory demands. By combining AF technology with built-in surge protection, it offers compact installation and predictable operations in challenging networks. The device also enables easy expansion with add-on auxiliary contact blocks, delivering scalable control without sacrificing performance or space. For engineers, this means simpler wiring, faster commissioning, and measurable energy efficiency gains across the lifecycle.

Product Information

Extended Description

1SFL607002R3100 ABB: The AF370-30-00-31 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 300 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 520 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
191 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 600 A | (690 V) 60 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 370 A | (440 V) 60 °C 370 A | (500 V) 60 °C 350 A | (690 V) 60 °C 315 A | (1000 V) 60 °C 141 A | (380 / 400 V) 60 °C 370 A | (220 / 230 / 240 V) 60 °C 370 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24...60 V | DC Operation 20...60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 9 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 9 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Holding at Max. Rated Control Circuit Voltage DC 3.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 72 W | at Rated Operating Conditions AC-3 per Pole 27 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 350 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 359 A | (220 ... 240 V AC) Three Phase 360 A | (440 ... 480 V AC) Three Phase 361 A | (550 ... 600 V AC) Three Phase 336 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561898
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature AF technology with a broad control voltage range of 24–60 V AC, 50/60 Hz and 20–60 V DC. Business Impact This accommodates large control voltage variations, reducing energy waste in variable networks and stabilizing actuation during irregular power events. Application Motor control circuits in industrial drives where voltage fluctuations are common and dependable coil operation is critical. Feature Three-pole main circuit with 1000 V rated operation and a versatile current spectrum (AC-1 up to 600 A, AC-3 up to 370 A at higher voltages). Business Impact Enables motor start and run for high-power loads (up to 200 kW at 400 V AC for AC-3) with reliable breaking and controlled switching, lowering maintenance costs and downtime. Application Heavy motor control in packaging, material handling, and process lines.Feature Built-in surge protection and compact AF block design. Business Impact Reduces external protection needs, simplifies panel layout, and improves energy efficiency by minimizing stray transients. Application Enclosures with space constraints or retrofits where quick, reliable protection is required.Feature Optional add-on auxiliary contact blocks for scalable control. Business Impact Supports advanced interlocking, signaling, and safety circuits without replacing the base unit. Application Control cabinets requiring expandable monitoring and interlocking schemes.Feature Flexible conductor connections (Flexible 0.75–2.5 mm²; Solid 1–4 mm²) and clear terminations. Business Impact Eases field wiring, reduces installation time, and improves reliability through robust terminations. Application Panel wiring in industrial controls and motor starter assemblies.Feature Compliance and lifecycle data (CE, UKCA, UL/CSA, RoHS; RoHS 2.0). Business Impact Provides regulatory assurance and easier maintenance planning across multi-region projects. Application Global deployments and ongoing compliance reporting.

Get a Quick Quote for a ABB 1SFL607002R3100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL607002R3100? Enquire Now

FAQs

This 3P AF block contactor is designed to work with add-on auxiliary contact blocks, enabling extended signaling and interlocking without replacing the base unit. Ensure compatibility by matching the AF series extension blocks to the 1SFL607002R3100 footprint and torque requirements, and follow the provided Operating Instructions for correct wiring and connector alignment.
For AC-3 operation, the unit provides 370 A at 690 V and 315–370 A across a range of voltages (e.g., 440–500 V and 380–400 V variants). It is rated for up to 200 kW at 415–690 V in AC-3, with a maximum breaking capacity of 5,000 A cos φ 0.45 for protective sizing and coordination with downstream protection devices.
Yes. The AF370-family capacity includes AC-3 power handling around 200 kW at 400 V and related voltages, making it suitable for medium- to high-power motors in conveyors, fans, and pumps. Verify the exact motor current (Ie) at your operating voltage and apply the rated operational current and short-time withstand ratings accordingly during protection coordination.
The unit meets CE and UKCA declarations, UL/CSA listings for global use, RoHS 2.0 compliance, and related environmental declarations. This combination supports regulatory compliance across European and North American markets and aligns with EN/IEC 60947-4-1 and UL/CSA guidelines for contactors and motor starters.
Expect reduced downtime due to robust AF technology and surge protection, energy savings from lower coil consumption during holding and operation, and easier maintenance through modular add-ons. The device’s mechanical durability (millions of cycles) and broad voltage tolerance also minimize reconfiguration costs when panel conditions change or new motors are commissioned.