ABB 1SFL607002R3222 Contactor - 1000V IEC / 600V UL, CE
Part Number: 1SFL607002R3222
Quick Summary
ABB AF370 Contactor is a three-pole motor switch used to start and stop medium-sized motors in industrial automation. When control voltages vary or networks are unstable, this design minimizes nuisance trips and energy waste. CE conformity, UL/CSA safety certification, and RoHS compliance ensure reliable operation in regulated facilities, while IP20 coil protection and IP00 main-terminal protection support rugged panel mounting. With AF technology delivering a wide control-voltage range of 48–130 V and built-in surge protection, it simplifies panel design and reduces energy use, delivering measurable cost savings for OEMs and maintenance teams alike.
Product Information
Extended Description
1SFL607002R3222 ABB: The AF370-30-22-32 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 300 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 520 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
8536490099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
160 mm
Product Net Depth / Length
191 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 600 A | (690 V) 60 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 370 A | (440 V) 60 °C 370 A | (500 V) 60 °C 350 A | (690 V) 60 °C 315 A | (1000 V) 60 °C 141 A | (380 / 400 V) 60 °C 370 A | (220 / 230 / 240 V) 60 °C 370 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | Holding at Max. Rated Control Circuit Voltage DC 2.5 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 360 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 72 W | at Rated Operating Conditions AC-3 per Pole 27 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x 0.75 ... 2.5 mm² | Flexible 2x 0.75 ... 2.5 mm² | Solid 1x 1 ... 4 mm² | Solid 2x 1 ... 4 mm² | Stranded 1x 1 ... 4 mm² | Stranded 2x 1 ... 4 mm²
Connecting Capacity
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Recommended Screw Driver
Main Circuit M10 | Control Circuit M3.5
Tightening Torque
Auxiliary Circuit 1 N·m | Cable Lug 28 N·m | Control Circuit 1 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 350 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 372 in·lb
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 359 A | (220 ... 240 V AC) Three Phase 360 A | (440 ... 480 V AC) Three Phase 361 A | (550 ... 600 V AC) Three Phase 336 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500561942
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → AF technology provides a wide control voltage range of 48–130 V AC/DC, delivering reliable operation across fluctuating power supplies and reducing the need for multiple controllers. Business Impact → Lower panel energy consumption and simplified control architecture translate to reduced wiring, shorter install times, and improved system uptime. Application → Suitable for packaging lines, conveyors, and process equipment where supply voltage varies but dependable motor control is essential. Feature → Built-in surge protection and a compact block-design enable easy cascading with add-on auxiliary blocks. Business Impact → Enhanced protection against voltage spikes and scalable expansion without new enclosure space, cutting lifecycle costs. Application → Ideal for modular motor control in high-density panel layouts. Feature → Three NO main contacts and two NO plus two NC auxiliary contacts provide flexible control circuits. Business Impact → More precise motor control and easier integration with current monitoring and signaling schemes. Application → Common in pumps, fans, and conveyors requiring reliable auxiliary signaling. Feature → Coil consumption figures show low standby power with effective pull-in performance. Business Impact → Energy-efficient operation reduces running costs and heat generation inside control panels. Application → Beneficial for widespread use in energy-conscious production lines. Feature → Compliance and durability features including UL/CSA certification, CE declaration, and RoHS compliance. Business Impact → Facilitates regulatory approvals and long-term reliability in harsh industrial environments. Application → Suitable for global deployments across facilities serving multiple markets.
Get a Quick Quote for a ABB 1SFL607002R3222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607002R3222?
Enquire Now
FAQs
The AF370-30-22-32 is a 3P block contactor designed for panel installation with main circuit bars. It requires a main circuit torque of 22–43 N·m and a control-circuit torque of 1 N·m. Coil terminals are IP20 protected and main terminals IP00, with dimensions of 160 mm width, 191 mm depth, and 225 mm height. Ensure proper clearance and fit within standard electrical enclosures and use the recommended M10 main-circuit screwdriver for secure connections.
Key ratings include main circuit voltage up to 1000 V, standard frequency 50/60 Hz, and rated currents AC-1 up to 400 A at 1000 V and AC-3 up to 370 A at 60 °C. Rated operational power reaches 200 kW at 690–1000 V, with a short-time withstand current up to 2960 A for 10 s at 40 °C. It also features a coil range of 48–130 V and built-in surge protection for enhanced reliability.
Yes. AF contactors are designed with a block-type architecture that can be extended with auxiliary contact blocks and a wide range of accessories. This enables enhanced signaling, interface options, and customization to meet specific control schemes without replacing the base device, simplifying maintenance and future upgrades.
The AF370 family carries UL/CSA certification and CE declarations of conformity, along with RoHS compliance. These certifications support regulatory approvals for global deployments and align with typical safety and environmental requirements in industrial facilities.
Expect high durability with up to 5 million mechanical cycles and energy-efficient coil consumption (holding 3 W at rated voltage, pull-in around 340 VA). The built-in surge protection and wide control voltage tolerance reduce nuisance trips and downtime, delivering lower maintenance costs and faster payback in motor-drive applications.